Induztr
Engineering Digest Document Viewer Related Models

IR ER IDS Launch Assets Digital Brochure

Technical Reference Summary

Covered Models & Document Scope

IDS Dry Screw Vacuum Pump series; document lists IDS 850 and IDS 1100 (water-cooled standard, air-cooled on request; fixed-speed IDS 850, variable-speed IDS 1100)

Technical Data

Parameter Value Condition
Max. pumping speed 810 m3/h p.5 ↗ IDS 850
Max. pumping speed 476 ft3/min p.5 ↗ IDS 850
Ultimate vacuum 0.03 mbar p.5 ↗ IDS 850
Motor power 18.5 kW p.5 ↗ IDS 850
Max. rotation speed 3000 rpm p.5 ↗ IDS 850
Motor type Fixed p.5 ↗ IDS 850
Dimensions (L × W × H) 1700×650×750 mm p.5 ↗ IDS 850
Inlet interface (flange) ISO100 p.5 ↗ IDS 850
Outlet interface (flange) ISO65 p.5 ↗ IDS 850
Total weight 909 kg p.5 ↗ IDS 850
Cooling water flow 15-20 L/min p.5 ↗ IDS 850
Cooling water supply pressure 5-35 barg p.5 ↗ IDS 850
Cooling water temperature 5-46 °C p.5 ↗ IDS 850
Cooling water inlet and outlet dimension G1/2” p.5 ↗ IDS 850
Noise 80 ±3 dB(A) p.5 ↗ IDS 850
Exhaust temperature 5-46 °C p.5 ↗ IDS 850
Exhaust back pressure 200 mbar(g) p.5 ↗ IDS 850
Max. pumping speed 1030 m3/h p.5 ↗ IDS 1100
Max. pumping speed 606 ft3/min p.5 ↗ IDS 1100
Ultimate vacuum 0.003 mbar p.5 ↗ IDS 1100
Motor power 18.5 / 22 kW p.5 ↗ IDS 1100
Max. rotation speed 3600 rpm p.5 ↗ IDS 1100
Motor type Variable p.5 ↗ IDS 1100
Dimensions (L × W × H) 1700×650×750 mm p.5 ↗ IDS 1100
Total weight 909 kg p.5 ↗ IDS 1100

Operating Limits

  • Cooling water temperature range: 5-46 °C p.5 ↗
  • Cooling water supply pressure range: 5-35 barg p.5 ↗
  • Cooling water flow range: 15-20 L/min p.5 ↗
  • Exhaust temperature range: 5-46 °C p.5 ↗
  • Exhaust back pressure: 200 mbar(g) p.5 ↗