Induztr
Engineering Digest Document Viewer Related Models

Technical Data Sheet — G-BH1 2BH1100 vacuum pump (EN)

Technical Reference Summary

Covered Models & Document Scope

G-BH1 side channel blower, data sheet 2BH1 100. Covers 2BH1100-1AH06, 2BH1100-1AC03, 2BH1100-7AV05 and the 2BH1100-..□.□ ordering code with voltage/frequency variants (H1, H6, H7, C3, C5, P3, P5, P6, P7).

Technical Data

Parameter Value Condition
Rated pressure 0,20 kW p.2 ↗ 2BH1100-1AH06, 50 Hz
Rated pressure 0,23 kW p.2 ↗ 2BH1100-1AH06, 60 Hz
Max. differential pressure vacuum -90 mbar p.2 ↗ 2BH1100-1AH06, 50 Hz
Max. differential pressure vacuum -120 mbar p.2 ↗ 2BH1100-1AH06, 60 Hz
Max. differential pressure pressure 100 mbar p.2 ↗ 2BH1100-1AH06, 50 Hz
Max. differential pressure pressure 120 mbar p.2 ↗ 2BH1100-1AH06, 60 Hz
Weight 10 kg p.2 ↗ 2BH1100-1AH06, 50 Hz
Weight 10 kg p.2 ↗ 2BH1100-1AH06, 60 Hz
Voltage 200-240 Δ / 345-415 Y V p.2 ↗ 2BH1100-1AH06, 50 Hz
Voltage 220-275 Δ / 380-480 Y V p.2 ↗ 2BH1100-1AH06, 60 Hz
Current 1,39 Δ / 0,80 Y A p.2 ↗ 2BH1100-1AH06, 50 Hz
Current 1,55 Δ / 0,90 Y A p.2 ↗ 2BH1100-1AH06, 60 Hz
Rated pressure 0,20 kW p.2 ↗ 2BH1100-1AC03, 50 Hz
Rated pressure 0,23 kW p.2 ↗ 2BH1100-1AC03, 60 Hz
Max. differential pressure vacuum -90 mbar p.2 ↗ 2BH1100-1AC03, 50 Hz
Max. differential pressure vacuum -120 mbar p.2 ↗ 2BH1100-1AC03, 60 Hz
Max. differential pressure pressure 100 mbar p.2 ↗ 2BH1100-1AC03, 50 Hz
Max. differential pressure pressure 120 mbar p.2 ↗ 2BH1100-1AC03, 60 Hz
Weight 10 kg p.2 ↗ 2BH1100-1AC03, 50 Hz
Weight 10 kg p.2 ↗ 2BH1100-1AC03, 60 Hz
Voltage 500 Y V p.2 ↗ 2BH1100-1AC03, 50 Hz
Voltage 575 Y V p.2 ↗ 2BH1100-1AC03, 60 Hz
Current 0,72 Y A p.2 ↗ 2BH1100-1AC03, 50 Hz
Current 0,76 Y A p.2 ↗ 2BH1100-1AC03, 60 Hz
Protection class IP 55 p.1 ↗ standard motors

Operating Limits

  • Max. suction and ambient temperature for stated total pressure differences: 25 °C p.1 ↗
  • Performance curve tolerance: ± 10 % p.1 ↗
  • Protection category: IP 55 p.1 ↗
  • Insulation class: F p.1 ↗
  • Three-phase motor voltage tolerance, fixed voltage motors: ±10 % p.2 ↗
  • Three-phase motor voltage tolerance, voltage range motors: ±5 % p.2 ↗

Type Code Decoder

Position Token Meaning
1-7 p.2 ↗ 2BH1100 Type/size: side channel blower G-BH1, size 100

Related models