Elmo Rietschle 2BH1100
Elmo Rietschle 2BH1100 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -90 mbar, Motor power 0.23 kW, Noise level 53 dB.
The 2BH1100 is a single-stage side-channel blower in Elmo Rietschle's G-BH1 series, available with either 3~ or 1~ motor. It delivers up to 120 mbar differential pressure in pressure mode and 110 mbar in vacuum at 50 Hz, with lower limits at 60 Hz. This modification is suited to low-flow applications requiring compact, low-power air movement.
Elmo Rietschle G-BH1 Series — Model Comparison & Selection
| Model | Motor power, kW | Noise level, dB | Weight, kg | Max. differential pressure, mbar | Current, A | Protection rating |
|---|---|---|---|---|---|---|
| 2BH1100 Current | 0.2 | 53 | 10 | -120 | 1.39 Δ / 0.80 Y | IP 55 |
| 2BH1009 | — | — | — | — | — | — |
| 2BH1014 | 0.32 | 57 | 11 | -55 | 3.2–6.5 | IP55 |
| 2BH1015 | 1.3 | 64 | 21 | -180 | 8–16 | IP55 |
| 2BH1023 | 1.75 | 69 | 69 | -190 | 10–20 | IP55 |
| 2BH1035 | 2.2 | 64 | 70 | -140 | 14.3–27 | IP55 |
| 2BH1200 | 0.29 | 40 | 57 | -40 | 1.38 0.8 Y | IP55 |
| 2BH1300 | 0.29 | 100 | 51 | -100 | 1.9 | IP 55 |
| 2BH1310 | 0.7 | 56 | 16 | -250 | 3.8 Δ / 2.20 Y | IP55 |
| 2BH1330 | 0.29 | 80 | 51 | — | 1.74 Δ / 1.0 Y | IP55 |
| 2BH1400 | 0.95 | 61 | 16 | -180 | 5.6 | IP55 |
| 2BH1410 | 2 | 65 | 28 | -300 | 6.9 | IP55 |
| 2BH1430 | 1.1 | 64 | 16 | 110 | 4.2 | IP55 |
| 2BH1490 | 0.95 | 61 | 16 | -140 | 4.8 VV | IP55 |
| 2BH1500 | 0.95 | 65 | 21 | -90 | 4.2 | IP55 |
| 2BH1510 | 4 | 71 | 48 | -400 | 7.6–15.2 | IP55 |
| 2BH1530 | 1.6 | 69 | 25 | -90 | 4.7 | IP55 |
| 2BH1590 | 1.3 | 61 | 21 | -190 | 2.75 | IP55 |
| 2BH1600 | 1.75 | 72 | 31 | 130 | 9.9 | IP55 |
| 2BH1610 | 2.5 | 75 | 48 | 160 | 6 | IP55 |
| 2BH1630 | 2.5 | 64 | 36 | -160 | 17.1 | IP55 |
| 2BH1640 | 4.6 | 65 | 65 | -240–260 | 17.1 | IP55 |
| 2BH1690 | 2.5 | 64 | 34 | -200 | 9.9 | IP55 |
| 2BH1800 | 5.8 | 77 | 131 | 260 | 11–22 | IP55 |
| 2BH1810 | 9.9 | 74 | 188 | -460 | 30.8 | IP55 |
| 2BH1830 | 5.8 | 75 | 133 | -160 | 19.4 | IP55 |
| 2BH1900 | 8.6 | 71 | 183 | -190 | 30.8 | IP55 |
| 2BH1910 | 12.6 | 76 | 295 | -220 | 26.4 | IP55 |
| 2BH1930 | 8.6 | 75 | 212 | -80 | 17.6–35.2 | IP55 |
| 2BH1940 | 19.9 | 73 | 303 | -150 | 63.1 | IP55 |
| 2BH1943 | 17.3 | 77 | 330 | -160 | 72.2 UU / 36.1 U | IP55 |
Full specifications
| Max. differential pressure | -90 mbar (50 Hz) 60 Hz: -120 mbar |
| Motor power | 0.20 kW (50 Hz) 60 Hz: 0.23 kW |
| Noise level | 50 dB(A) (50 Hz) 60 Hz: 53 dB(A) |
| Pumping speed | 70 m³/hour (50 Hz) |
| Max. differential pressure vacuum mfr | -120 mbar (60 Hz) |
| Order No. mfr | 2BH1100-7AV05 |
| Certification mfr | UL and CSA approved |
| Rated pressure (vacuum) mfr | -90 mbar (50 Hz) |
| Rated pressure (vacuum) mfr | -120 mbar (60 Hz) |
| Max. differential pressure (pressure level) mfr | 100 mbar (50 Hz) |
| Max. differential pressure (pressure level) mfr | 120 mbar (60 Hz) |
| Performance curve tolerance mfr | ±10 % |
| Max. differential pressure (alt 50 Hz) mfr | 100 mbar (50 Hz) |
| Max. differential pressure (alt 60 Hz) mfr | 120 mbar (60 Hz) |
| Weight | 10 kg |
| Weight approx. mfr | 11 kg |
| Current | 1.39 Δ / 0.80 Y A (50 Hz) 60 Hz: 1.55 Δ / 0.90 Y A |
| Frequency | 50 Hz (50 Hz) 60 Hz: 60 Hz |
| Voltage | 200-240 Δ / 345-415 Y V (50 Hz) 60 Hz: 220-275 Δ / 380-480 Y V |
| Frequency tolerance mfr | ±2 % |
| Voltage tolerance three-phase fixed voltage mfr | ±10 % |
| Voltage tolerance three-phase voltage range mfr | ±5 % |
| Voltage tolerance single phase mfr | ±5 % |
| Protection rating | IP 55 |
| Operating temperature | 25 degC |
| Sound pressure level mfr | 50 dB(A) (50 Hz) |
| Sound pressure level mfr | 53 dB(A) (60 Hz) |
Description
Construction and series positioning
- Single-stage side-channel (regenerative) blower with integrated motor; no external drive or coupling.
- Offered in two motor variants: 3~ 220–275 Δ / 380–480 Y V and 1~ 115/230 V, both 50/60 Hz.
- Weighs 10 kg; IP55 protection and class F insulation.
- Within the G-BH1 series, the 2BH1100 is a low-power model (0.76 kW at 3~, 0.23 kW at 1~), while siblings 2BH1009, 2BH1014, 2BH1015, and 2BH1023 cover higher capacities.
Performance behavior
- Maximum differential pressure at 50 Hz: 110 mbar vacuum, 120 mbar pressure.
- At 60 Hz, maximum differential pressure is 90 mbar vacuum and 100 mbar pressure.
- Sound pressure level: 53 dB(A) at 50 Hz, 60 dB(A) at 60 Hz.
- No digitized curve points are available; performance curves must be requested from the manufacturer for precise flow-pressure mapping.
Installation and operation
- The technical data sheet covers specific model codes (2BH1100-1AH06, -1AC03, -7AV05) and voltage variants; verify the exact code when ordering.
- Motor connection must match the available supply: 3~ delta or star, or 1~ 115/230 V.
- The blower is air-cooled; ensure unobstructed ventilation and adequate clearance.
- No additional installation, control, or maintenance details are provided in the available document digest.
Integration & Operating Notes
The 2BH1100 is available with either a 3~ motor (220–275 V Δ / 380–480 V Y) or a 1~ motor (115/230 V). Connecting a 3~ unit to a single-phase supply, or applying the wrong voltage, will damage the motor. Confirm the model code suffix (e.g., -1AH06, -1AC03, -7AV05) against the nameplate and the technical data sheet before wiring.
The blower relies on ambient air for cooling. Install in a location with sufficient clearance and avoid enclosing the unit in a sealed cabinet without ventilation. Ambient temperature and altitude may further derate performance; consult the manufacturer if operating above standard conditions.
Selection & Integration Q&A
Choose the 2BH1100 when your required differential pressure is up to 120 mbar and flow demand is low, and you need a compact 10 kg unit. For higher flow or pressure, step up to siblings 2BH1009, 2BH1014, 2BH1015, or 2BH1023, which offer larger capacities.
The available data sheet does not specify ambient temperature limits or duty cycle. The only temperature-related value in the data sheet is an operating temperature of 25 °C, which is not an ambient limit. Do not assume a generic 40 °C rating; confirm the permissible ambient temperature and duty cycle with Elmo Rietschle for this model. Ensure adequate ventilation to prevent overheating.
The base delivery includes only the blower; no filters, silencers, or connection fittings are included. No maintenance schedule is provided in the data sheet. Request the full instruction manual for bearing inspection intervals and available accessories such as inlet filters or flexible connectors.