Technical Data Sheet — 2BH1500 IE3 vacuum pump (EN)

Technical Reference Summary

Covered Models & Document Scope

Data sheet 2BH1 500, side channel blower with IE3-motors, 3~ 50/60 Hz, IP55, insulation class F, UL 1450 and CAN/CSA C22.2 No. 68-09 (certificate E225239). Covers sizes 1-4 and voltage variants K (190-210 V Δ / 380-420 V Y), Q (475-525 V Y / 550-600 V Y, 220-240 V Δ / 380-420 V Y, 400 V Δ / 690 V Y), with IE3 or NP motor efficiency class.

Technical Data

Parameter Value Condition
Rated voltage 190-210 V p.2 ↗ 2BH1500-0AK01, 50 Hz, Δ
Rated current 4,2 A p.2 ↗ 2BH1500-0AK01, 50 Hz, Δ
Motor power 0,95 kW p.2 ↗ 2BH1500-0AK01, 50 Hz
Max. differential pressure -90 mbar p.2 ↗ 2BH1500-0AK01, 50 Hz
Max. differential pressure 90 mbar p.2 ↗ 2BH1500-0AK01, 50 Hz
Sound pressure level 59 dB(A) p.2 ↗ 2BH1500-0AK01, 50 Hz
Weight 21 kg p.2 ↗ 2BH1500-0AK01, 50 Hz
Rated voltage 190-210 / 380-420 V p.2 ↗ 2BH1500-0AK01, 60 Hz, Δ/Y
Rated current 4,8 / 2,4 A p.2 ↗ 2BH1500-0AK01, 60 Hz, Δ/Y
Motor power 1,10 kW p.2 ↗ 2BH1500-0AK01, 60 Hz
Max. differential pressure -80 mbar p.2 ↗ 2BH1500-0AK01, 60 Hz
Max. differential pressure 80 mbar p.2 ↗ 2BH1500-0AK01, 60 Hz
Sound pressure level 65 dB(A) p.2 ↗ 2BH1500-0AK01, 60 Hz
Rated voltage 220-240 / 380-420 V p.2 ↗ 2BH1500-0AK06, 50 Hz, Δ/Y
Rated current 3,7 / 2,1 A p.2 ↗ 2BH1500-0AK06, 50 Hz, Δ/Y
Motor power 0,95 kW p.2 ↗ 2BH1500-0AK06, 50 Hz
Max. differential pressure -90 mbar p.2 ↗ 2BH1500-0AK06, 50 Hz
Max. differential pressure 90 mbar p.2 ↗ 2BH1500-0AK06, 50 Hz
Sound pressure level 59 dB(A) p.2 ↗ 2BH1500-0AK06, 50 Hz
Weight 21 kg p.2 ↗ 2BH1500-0AK06, 50 Hz
Rated voltage 475-525 V p.2 ↗ 2BH1500-0AQ03, 50 Hz, Y
Rated current 1,7 A p.2 ↗ 2BH1500-0AQ03, 50 Hz, Y
Motor power 0,95 kW p.2 ↗ 2BH1500-0AQ03, 50 Hz
Max. differential pressure -90 mbar p.2 ↗ 2BH1500-0AQ03, 50 Hz
Sound pressure level 59 dB(A) p.2 ↗ 2BH1500-0AQ03, 50 Hz

Operating Limits

  • Protection category: IP55 p.2 ↗
  • Insulation class: F p.2 ↗
  • Max. ambient temperature for pressure data: 25 °C p.1 ↗
  • Performance tolerance: ± 10 % p.1 ↗
  • Reference air temperature: 15 °C p.1 ↗
  • Reference atmospheric pressure: 1013 mbar p.1 ↗

Type Code Decoder

Position Token Meaning
1-5 p.2 ↗ 2BH1 Series: side channel blower
6-8 p.2 ↗ 500 Size 500

Ordering Data

Ordering Code Part No. Variant / Code Applies To Note
2BH1500-0AK01 p.2 ↗ 2BH1500-0AK01 IE3, 50/60 Hz, 190-210 V Δ / 380-420 V Y Size 1
2BH1500-0AK11 p.2 ↗ 2BH1500-0AK11 IE3, 50/60 Hz, 190-210 V Δ / 380-420 V Y Size 2
2BH1500-0AK21 p.2 ↗ 2BH1500-0AK21 IE3, 50/60 Hz, 190-210 V Δ / 380-420 V Y Size 3
2BH1500-0AK31 p.2 ↗ 2BH1500-0AK31 IE3, 50/60 Hz, 190-210 V Δ / 380-420 V Y Size 4
2BH1500-0AK06 p.2 ↗ 2BH1500-0AK06 IE3, 50/60 Hz, 220-240 V Δ / 380-420 V Y Size 1
2BH1500-0AK16 p.2 ↗ 2BH1500-0AK16 IE3, 50/60 Hz, 220-240 V Δ / 380-420 V Y Size 2
2BH1500-0AK26 p.2 ↗ 2BH1500-0AK26 IE3, 50/60 Hz, 220-240 V Δ / 380-420 V Y Size 3
2BH1500-0AK36 p.2 ↗ 2BH1500-0AK36 IE3, 50/60 Hz, 220-240 V Δ / 380-420 V Y Size 4
2BH1500-0AQ03 p.2 ↗ 2BH1500-0AQ03 IE3, 50/60 Hz, 475-525 V Y / 550-600 V Y Size 1
2BH1500-0AQ13 p.2 ↗ 2BH1500-0AQ13 IE3, 50/60 Hz, 475-525 V Y / 550-600 V Y Size 2

Related models