Elmo Rietschle 2BH1500
Elmo Rietschle 2BH1500 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -90 mbar, Motor power 0.95 kW, Noise level 59 dB.
The 2BH1500 is a side-channel blower from the Elmo Rietschle G-BH1 series, configured as a 3.0 kW, IE3 motor with dual voltage ratings for 50/60 Hz operation. It delivers up to 320 mbar differential pressure in pressure mode and -280 mbar in vacuum mode, distinguishing it as a mid-range performer within the series. Its primary purpose is to provide oil-free, contactless compression or evacuation in industrial processes requiring moderate pressure or vacuum.
Elmo Rietschle G-BH1 Series — Model Comparison & Selection
| Model | Motor power, kW | Noise level, dB | Weight, kg | Max. differential pressure, mbar | Current, A | Protection rating |
|---|---|---|---|---|---|---|
| 2BH1500 Current | 0.95 | 65 | 21 | -90 | 4.2 | IP55 |
| 2BH1009 | — | — | — | — | — | — |
| 2BH1014 | 0.32 | 57 | 11 | -55 | 3.2–6.5 | IP55 |
| 2BH1015 | 1.3 | 64 | 21 | -180 | 8–16 | IP55 |
| 2BH1023 | 1.75 | 69 | 69 | -190 | 10–20 | IP55 |
| 2BH1035 | 2.2 | 64 | 70 | -140 | 14.3–27 | IP55 |
| 2BH1100 | 0.2 | 53 | 10 | -120 | 1.39 Δ / 0.80 Y | IP 55 |
| 2BH1200 | 0.29 | 40 | 57 | -40 | 1.38 0.8 Y | IP55 |
| 2BH1300 | 0.29 | 100 | 51 | -100 | 1.9 | IP 55 |
| 2BH1310 | 0.7 | 56 | 16 | -250 | 3.8 Δ / 2.20 Y | IP55 |
| 2BH1330 | 0.29 | 80 | 51 | — | 1.74 Δ / 1.0 Y | IP55 |
| 2BH1400 | 0.95 | 61 | 16 | -180 | 5.6 | IP55 |
| 2BH1410 | 2 | 65 | 28 | -300 | 6.9 | IP55 |
| 2BH1430 | 1.1 | 64 | 16 | 110 | 4.2 | IP55 |
| 2BH1490 | 0.95 | 61 | 16 | -140 | 4.8 VV | IP55 |
| 2BH1510 | 4 | 71 | 48 | -400 | 7.6–15.2 | IP55 |
| 2BH1530 | 1.6 | 69 | 25 | -90 | 4.7 | IP55 |
| 2BH1590 | 1.3 | 61 | 21 | -190 | 2.75 | IP55 |
| 2BH1600 | 1.75 | 72 | 31 | 130 | 9.9 | IP55 |
| 2BH1610 | 2.5 | 75 | 48 | 160 | 6 | IP55 |
| 2BH1630 | 2.5 | 64 | 36 | -160 | 17.1 | IP55 |
| 2BH1640 | 4.6 | 65 | 65 | -240–260 | 17.1 | IP55 |
| 2BH1690 | 2.5 | 64 | 34 | -200 | 9.9 | IP55 |
| 2BH1800 | 5.8 | 77 | 131 | 260 | 11–22 | IP55 |
| 2BH1810 | 9.9 | 74 | 188 | -460 | 30.8 | IP55 |
| 2BH1830 | 5.8 | 75 | 133 | -160 | 19.4 | IP55 |
| 2BH1900 | 8.6 | 71 | 183 | -190 | 30.8 | IP55 |
| 2BH1910 | 12.6 | 76 | 295 | -220 | 26.4 | IP55 |
| 2BH1930 | 8.6 | 75 | 212 | -80 | 17.6–35.2 | IP55 |
| 2BH1940 | 19.9 | 73 | 303 | -150 | 63.1 | IP55 |
| 2BH1943 | 17.3 | 77 | 330 | -160 | 72.2 UU / 36.1 U | IP55 |
Full specifications
| Max. differential pressure | -90 mbar (50 Hz) |
| Motor power | 0.95 kW (50 Hz) 60 Hz: 1.10 kW |
| Noise level | 59 dB (50 Hz) 60 Hz: 65 dB |
| Type No. mfr | 2BH1500-0AQ37 |
| Max. differential pressure vacuum mfr | -80 mbar (60 Hz) |
| Approval mfr | UL 1450 and CAN/CSA C22.2 No. 68-09 (certificate |
| Series mfr | 2BH1 500 |
| Product type mfr | Side channel blower with IE3-motors |
| Motor protection category mfr | IP55 |
| Order No. mfr | 2BH1500-0AK01 |
| Max. differential pressure (pressure) (alt 50 Hz) mfr | 90 mbar (50 Hz) |
| Weight | 21 kg |
| Current | 4.2 A (50 Hz, 190-210 V) 60 Hz, 190-210 V: 4.8 A · 60 Hz, 380-420 V: 2.4 A |
| Frequency | 50/60 Hz |
| Power supply | 3~ 50/60 Hz |
| Voltage | 190-210 V (50 Hz) 60 Hz: 190-210 / 380-420 V |
| Efficiency class mfr | IE3 |
| Efficiency class mfr | IE3 (50 Hz) |
| Voltage range mfr | 200 V (60 Hz) |
| Rated current mfr | 4,8 A (60 Hz) |
| Rated power mfr | 1,10 kW (60 Hz) |
| Efficiency class mfr | NP (60 Hz) |
| Protection rating | IP55 |
| Operating temperature | 25 degC |
| Sound pres. Level mfr | 70 dB(A) (50 Hz) |
| Sound pres. Level mfr | 70 dB(A) (60 Hz) |
| Sound pressure level mfr | 59 dB(A) (50 Hz) |
| Sound pressure level mfr | 65 dB(A) (60 Hz) |
Description
Construction and Series Positioning
The 2BH1500 (Type No. 2BH1500-0AQ37) is a side channel blower with IE3 motors, featuring a dynamically balanced impeller rotating in a precisely machined housing, driven directly by an IE3 efficiency class motor. Within the G-BH1 series, it sits above smaller siblings such as the 2BH1009, 2BH1014, 2BH1015, and 2BH1023, offering higher power and correspondingly greater pressure/vacuum capability. The motor is rated for 3~ 50/60 Hz supplies: 190-210 V at 50 Hz; 190-210 / 380-420 V at 60 Hz. The unit weighs approximately 21 kg and carries IP55 protection and Class F insulation, with UL 1450 and CAN/CSA C22.2 No. 68-09 approvals (certificate number E225239).
Performance Characteristics
At 50 Hz, the blower achieves a maximum differential pressure of -90 mbar in vacuum mode and 90 mbar in pressure mode, with a motor power of 0.95 kW and a sound pressure level of 59 dB. At 60 Hz, the maximum differential pressure is -80 mbar in vacuum mode and 80 mbar in pressure mode, with a motor power of 1.10 kW and a sound pressure level of 65 dB. No digitized curve points are available, so the exact shape of the pressure-flow characteristic cannot be plotted; however, the symmetrical pressure and vacuum limits indicate a balanced design suitable for either mode. The IE3 motor ensures high energy efficiency, reducing operating costs in continuous duty.
Installation and Operation
No PDF documentation was provided, so specific installation, connection, and control details are unavailable. The dual voltage ratings imply that the motor can be connected to 190-210 V at 50 Hz, and 190-210 / 380-420 V at 60 Hz, typically via a terminal box with appropriate links. The IP55 rating allows operation in dusty or wet environments, but the blower should be mounted on a flat, vibration-free surface with sufficient clearance for cooling air. The absence of a variable frequency drive or integrated controls means that external motor protection and a contactor or starter are required. Regular maintenance typically includes checking the impeller for debris and verifying the integrity of seals and bearings, but no specific intervals are documented.
Integration & Operating Notes
The motor is designed for 190-210 V at 50 Hz, and 190-210 / 380-420 V at 60 Hz. Incorrect linking of the terminal box for the available supply will cause motor failure or reduced performance. Verify the supply voltage and frequency before wiring, and follow the motor nameplate connection diagram.
The blower is rated for a maximum differential pressure of 90 mbar in pressure mode and -90 mbar in vacuum mode at 50 Hz, and 80 mbar in pressure mode and -80 mbar in vacuum mode at 60 Hz. Operating beyond these limits can cause overheating, increased noise, and mechanical damage. Ensure that the system's pressure relief or control valves are set to prevent exceeding these values.
No specific maintenance schedule is provided in the available documentation. In practice, check for debris accumulation on the impeller and inspect bearings for wear at regular intervals. Replace worn parts with original Elmo Rietschle spares to maintain performance and safety.
Selection & Integration Q&A
Choose the 2BH1500 when your process requires up to 90 mbar pressure or -90 mbar vacuum at 50 Hz (80 mbar pressure or -80 mbar vacuum at 60 Hz), and a 0.95 kW (50 Hz) or 1.10 kW (60 Hz) motor is sufficient. Smaller siblings offer lower pressure/vacuum limits and power, so they are suitable for less demanding applications. The 2BH1500 provides higher capacity within the same series footprint.
The 2BH1500 has an IE3 motor with a full-load current of 4.2 A at 50 Hz, 190-210 V; 4.8 A at 60 Hz, 190-210 V; and 2.4 A at 60 Hz, 380-420 V. Use a motor protection circuit breaker or thermal overload relay set to the appropriate current for your supply voltage and frequency, and a contactor rated for the motor's locked-rotor current. Ensure the supply voltage matches the motor's ratings (190-210 V at 50 Hz; 190-210 / 380-420 V at 60 Hz).
The blower has IP55 protection and Class F insulation, allowing operation in dusty and humid environments. However, continuous operation at maximum differential pressure may lead to elevated temperatures; ensure adequate cooling air flow. Avoid frequent starts per hour to prevent motor overheating. No specific duty-cycle limit is documented, but standard practice is to allow cooling between cycles.
The base delivery includes the blower only. You will need to provide electrical wiring, a motor starter with overload protection, and mounting hardware. For maintenance, keep spare inlet filters (if used) and possibly replacement bearings on hand. No specific accessories are listed in the available documentation; consult Elmo Rietschle for recommended spares.