Technical Data Sheet — 2BH721 IE3 vacuum pump (EN)
Technical Reference Summary
Covered Models & Document Scope
Data sheet 2BH7 210, G-BH 7 N side channel blower with IE3 motors; covers 50 Hz and 60 Hz variants with various voltage codes (K1, K6, Q3, Q5, Q6, Q7) and order numbers 2BH7210-0AK31-1, 2BH7210-0AK36-1, 2BH7210-0AQ33-1, 2BH7210-0AQ36-1, 2BH7210-0AQ37-1
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Rated pressure (vacuum) | -230 mbar p.2 ↗ | 2BH7210, 50 Hz |
| Rated pressure (vacuum) | -300 mbar p.2 ↗ | 2BH7210, 60 Hz |
| Rated pressure (compressor) | 290 mbar p.2 ↗ | 2BH7210, 50 Hz |
| Rated pressure (compressor) | 420 mbar p.2 ↗ | 2BH7210, 60 Hz |
| Voltage | 190-210 V p.2 ↗ | 2BH7210-0AK31-1, 50 Hz, delta |
| Voltage | 190-210 / 380-420 V p.2 ↗ | 2BH7210-0AK31-1, 60 Hz, delta/Y |
| Voltage | 220-240 / 380-420 V p.2 ↗ | 2BH7210-0AK36-1, 50 Hz, delta/Y |
| Voltage | 220-240 / 440-480 V p.2 ↗ | 2BH7210-0AK36-1, 60 Hz, delta/Y |
| Voltage | 500 V p.2 ↗ | 2BH7210-0AQ33-1, 50 Hz, Y |
| Voltage | 575 V p.2 ↗ | 2BH7210-0AQ33-1, 60 Hz, Y |
| Voltage | 380-420 / 660-725 V p.2 ↗ | 2BH7210-0AQ37-1, 50 Hz, delta/Y |
| Voltage | 440-480 V p.2 ↗ | 2BH7210-0AQ37-1, 60 Hz, delta |
| Current | 4,2 A p.2 ↗ | 2BH7210-0AK31-1, 50 Hz |
| Current | 4,8 A p.2 ↗ | 2BH7210-0AK31-1, 60 Hz |
| Current | 3,7 / 2,1 A p.2 ↗ | 2BH7210-0AK36-1, 50 Hz, delta/Y |
| Current | 4,2 / 2,1 A p.2 ↗ | 2BH7210-0AK36-1, 60 Hz, delta/Y |
| Current | 1,7 A p.2 ↗ | 2BH7210-0AQ33-1, 50 Hz |
| Current | 2,1 / 1,2 A p.2 ↗ | 2BH7210-0AQ37-1, 50 Hz, delta/Y |
| Power | 1,0 kW p.2 ↗ | 2BH7210, 50 Hz |
| Power | 1,1 kW p.2 ↗ | 2BH7210, 60 Hz |
| Sound pressure level | 59 dB(A) p.2 ↗ | 2BH7210, 50 Hz |
| Sound pressure level | 63 dB(A) p.2 ↗ | 2BH7210, 60 Hz |
| Weight | 21 kg p.2 ↗ | 2BH7210 |
| Protection category | IP 55 p.1 ↗ | |
| Insulation class | F p.1 ↗ |
Operating Limits
- Max suction and ambient temperature for stated total pressure differences: 25 °C p.1 ↗
- Performance curve tolerance: ± 10 % p.1 ↗
- Protection category: IP 55 p.1 ↗
- Insulation class: F p.1 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-5 p.2 ↗ | 2BH7… | Series / type designation (side channel blower, G-BH 7 N) |
| field 1 p.2 ↗ | K / Q | Voltage variant group (K = 190-240 V range, Q = 380-725 V range) |
| field 2 p.2 ↗ | 1 / 6 / 3 / 5 / 7 | Specific voltage/frequency code within the group |
| field 3 p.2 ↗ | □ | Placeholder for voltage code (K1, K6, Q3, Q5, Q6, Q7) |
| field 4 p.2 ↗ | □ | Placeholder for additional option (not further specified in document) |
| suffix p.2 ↗ | -1 | Design variant / revision |
Ordering Data
| Ordering Code | Part No. | Variant / Code | Applies To | Note |
|---|---|---|---|---|
| 2BH7210-0AK31-1 p.2 ↗ | 2BH7210-0AK31-1 | K1 | 50/60 Hz, 190-210 V Δ / 190-210 V YY / 220-240 V Δ / 380-420 V Y | IE3 motor |
| 2BH7210-0AK36-1 p.2 ↗ | 2BH7210-0AK36-1 | K6 | 50/60 Hz, 220-240 V Δ / 380-420 V Y; 60 Hz: 220-240 V YY / 440-480 V Y | IE3 motor |
| 2BH7210-0AQ33-1 p.2 ↗ | 2BH7210-0AQ33-1 | Q3 | 50/60 Hz, 500 V Y; 60 Hz: 575 V Y | IE3 motor |
| 2BH7210-0AQ36-1 p.2 ↗ | 2BH7210-0AQ36-1 | Q6 | 50/60 Hz, 220-240 V Δ / 380-420 V Y; 60 Hz: 440-480 V Y | IE3 motor |
| 2BH7210-0AQ37-1 p.2 ↗ | 2BH7210-0AQ37-1 | Q7 | 50/60 Hz, 380-420 V Δ / 660-725 V Y; 60 Hz: 440-480 V Δ / 460 V Δ | IE3 motor |