Elmo Rietschle 2BH721
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle 2BH721

Elmo Rietschle 2BH721 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -230 mbar, Motor power 1 kW, Noise level 63 dB.

The 2BH721 is a three-phase side-channel blower in the G-BH7 series, fitted with an IE3 efficiency motor and rated 1.0 kW at 50 Hz / 1.1 kW at 60 Hz. It delivers up to 290 mbar pressure and -230 mbar vacuum at 50 Hz (420 mbar / -300 mbar at 60 Hz), distinguishing it from lower-output siblings such as the 2BH722. It serves as a compact pressure/vacuum source for pneumatic conveying, aeration, or holding duties where a small, high-efficiency ring blower is required.

Max. differential pressure
-230 mbar
Motor power
1 kW
Noise level
63 dB
Ultimate pressure
290 mbar
Weight
21 kg

Elmo Rietschle G-BH7 Series — Model Comparison & Selection

Model Motor power, kWNoise level, dBMax. differential pressure, mbarWeight, kgCurrent, AVoltage, V
2BH721 Current 159-300214.2190–210
2BH7210 0.6363-270163.0 △ / 1.7 Y220-275 △ / 380-480 Y
2BH722 1.158480284.8 UU / 2.4 U190-210 UU / 380-420 U
2BH7220 0.8158-440244220-275 / 380-480 Y
2BH731 1.163-340242.8–5.5190-210 / 380-420
2BH7310 0.6358250—2.8200-240 / 345-415 Y
2BH732 1.364440333.2190-210 / 380-420
2BH7320 3.577-510486.5—
2BH741 1.363—266.3190–210
2BH7410 2.673-230335.2400
2BH742 1.864460383.9–7.8190-210 / 380-420
2BH7420 2.977-270456.5380
2BH751 1.868-340337.8 UU190-210 UU / 380-420 U
2BH7510 6.6784304312.7400
2BH752 2.564-5205012190-210 / 380-420
2BH7520 4.377-520578.7400 V (-15%) … 480 V (+1
2BH753 5.3699507217.1190–210
2BH7530 7.570-6108016.2400
2BH7610 5.880-4105512.7380
2BH7620 8.879-5307716.2400
2BH7630 1680-50012129400

Full specifications

Core Performance & Functional Specifications
Max. differential pressure -230 mbar (50 Hz)
60 Hz: -300 mbar
Motor power 1.0 kW (50 Hz)
60 Hz: 1.1 kW
Noise level 59 dB(A) (50 Hz)
60 Hz: 63 dB(A)
Ultimate pressure 290 mbar (50 Hz)
60 Hz: 420 mbar
Max. differential pressure vacuum mfr -300 mbar (60 Hz)
Efficiency mfr IE3 (60 Hz)
Approval mfr UL 1450 and CAN/CSA C22.2 No. 68-09 (certificate
Vacuum mfr -230 mbar (50 Hz)
Efficiency mfr IE3 (50 Hz)
Vacuum mfr -300 mbar (60 Hz)
Efficiency mfr NP (60 Hz, 200 V YY)
Order No. mfr 2BH7210-0AK31-1
Certification mfr UL 1450 and CAN/CSA C22.2 No. 68-09 (certificate
Dimensions, Weight & Mechanical Design
Weight 21 kg (50 Hz)
Electrical, Power & Drive Specifications
Current 4.2 A (50 Hz)
60 Hz: 4.8 A
Frequency 50 Hz (50 Hz)
60 Hz: 60 Hz
Power supply 3~ 50/60 Hz
Voltage 190-210 V (50 Hz)
60 Hz: 190-210 V
Voltage connection mfr 460 Δ V (60 Hz)
Phase mfr 3~
Voltage tolerance mfr ±10 %
Frequency tolerance mfr ±2 %
Rated frequency mfr 60 Hz (60 Hz)
Voltage (alt 60 Hz) mfr 380-420 V (60 Hz)
Current (alt 60 Hz) mfr 2.4 A (60 Hz)
Operating Conditions, Environment & Protection
Protection rating IP55
Sound pressure level mfr 63 dB(A) (60 Hz)
Sound pressure level mfr 59 dB(A) (50 Hz)

Description

Construction and series positioning

Performance behaviour

Electrical and compliance

Integration & Operating Notes

Electrical
Supply must stay within ±10 % voltage and ±2 % frequency

The IE3 motor is wound for 380–420 V Δ / 660–725 Y at 50 Hz and 460 V Δ at 60 Hz. Operating outside the stated tolerances risks overheating, loss of efficiency and reduced bearing life; verify the actual site voltage and frequency before connecting, especially on 60 Hz grids where only the 460 V delta connection is specified.

Factory Specification Sheet, extra_specs Voltage/Frequency tolerance
Electrical
Provide motor protection and correct rotation before startup

Because the blower is a three-phase machine with no integrated starter, the panel must include overload protection sized to the 2.1 A delta current and a phase-sequence check. Running the blower backwards reverses the air flow direction and can overload the motor; confirm rotation at first start before coupling to the process.

Technical Data Sheet — 2BH721 IE3 vacuum pump (EN
Mounting
IP55 enclosure permits outdoor and washdown-adjacent installation

The IP55 motor and class F insulation allow installation in dusty or damp industrial environments, but the blower still needs a firm, level base and unobstructed intake/exhaust. Ensure sufficient clearance around the motor fan cowl for cooling air, since the 63 dB(A) sound level and 1.1 kW losses are dissipated convectively.

Factory Specification Sheet, extra_specs Protection category
Maintenance
No consumables or cables are included in base delivery

The base unit is supplied without power cable, starter or process connections; these must be ordered separately. Scheduled maintenance is limited to bearing inspection and cleaning of the impeller/side channel; the manual digest provides no fixed interval, so follow the series service schedule and check bearings at each shutdown.

Technical Data Sheet — 2BH721 IE3 vacuum pump (EN

Selection & Integration Q&A

When should I choose the 2BH721 rather than the 2BH722 or 2BH731?

Pick the 2BH721 when you need roughly 1.0–1.1 kW and up to 290/420 mbar with IE3 efficiency. The 2BH722 is a lower-output sibling; the 2BH731 is larger. Choose the 2BH7210 if IE3 is not required.

What supply and protection does the 2BH721 need from the control panel?

A three-phase 50/60 Hz supply within ±10 % voltage and ±2 % frequency, a contactor and overload set to 2.1 A (delta), and a phase-sequence check. No starter or cable is included, so these are panel-side scope.

What mounting and duty-cycle limits apply to this blower?

Mount on a firm level base with cooling-air clearance around the IP55 motor. Continuous duty is limited by the 290 mbar (50 Hz) / 420 mbar (60 Hz) differential-pressure ceiling; blocked flow raises current above 2.1 A and must be avoided.

What maintenance and accessories are needed beyond the base unit?

Order power cable, starter and process flanges separately. Maintenance is bearing inspection and impeller/side-channel cleaning; no fixed interval is given in the digest, so follow the G-BH7 series schedule and check at each shutdown.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — 2BH721 IE3 vacuum pump (EN)
Datasheet ·359,7 КБ ·2 pp.
View PDF