Technical Reference Summary
Covered Models & Document Scope
Data sheet 2BH7 220 side channel blower (G-BH7 series), Edition 07/2021. Covers 2BH7220 variants: 2BH7220-0AH26-1, 2BH7220-0AH56-1, 2BH7220-0AC23-1, 2BH7220-0AC53-1, 2BH7220-0AV74-7, 2BH7220-0AV75-7, plus ordering code 2BH7220-0.□.□ with motor variants H1, H6, H7, C3, C5, P1, P3, P5, P6, P7 for 50/60 Hz and VFD 87 Hz operation.
Technical Data
| Parameter |
Value |
Condition |
| Rated pressure (vacuum) |
-370 mbar
p.2 ↗ |
2BH7220-0AH26-1, 50 Hz |
| Max. differential pressure |
490 mbar
p.2 ↗ |
2BH7220-0AH26-1, 50 Hz |
| Sound pressure level |
58 dB(A)
p.2 ↗ |
2BH7220-0AH26-1, 50 Hz |
| Weight |
24 kg
p.2 ↗ |
2BH7220-0AH26-1, 50 Hz |
| Voltage |
200-240 / 345-415 Y V
p.2 ↗ |
2BH7220-0AH26-1, 50 Hz |
| Current |
4.0 / 2.3 Y A
p.2 ↗ |
2BH7220-0AH26-1, 50 Hz |
| Power |
0.81 kW
p.2 ↗ |
2BH7220-0AH26-1, 50 Hz |
| Rated pressure (vacuum) |
-440 mbar
p.2 ↗ |
2BH7220-0AH26-1, 60 Hz |
| Max. differential pressure |
480 mbar
p.2 ↗ |
2BH7220-0AH26-1, 60 Hz |
| Sound pressure level |
63 dB(A)
p.2 ↗ |
2BH7220-0AH26-1, 60 Hz |
| Weight |
24 kg
p.2 ↗ |
2BH7220-0AH26-1, 60 Hz |
| Voltage |
220-275 / 380-480 Y V
p.2 ↗ |
2BH7220-0AH26-1, 60 Hz |
| Current |
4.0 / 2.3 Y A
p.2 ↗ |
2BH7220-0AH26-1, 60 Hz |
| Power |
0.94 kW
p.2 ↗ |
2BH7220-0AH26-1, 60 Hz |
| Rated pressure (vacuum) |
-370 mbar
p.2 ↗ |
2BH7220-0AH56-1, 50 Hz |
| Max. differential pressure |
650 mbar
p.2 ↗ |
2BH7220-0AH56-1, 50 Hz |
| Sound pressure level |
58 dB(A)
p.2 ↗ |
2BH7220-0AH56-1, 50 Hz |
| Weight |
29 kg
p.2 ↗ |
2BH7220-0AH56-1, 50 Hz |
| Power |
1.50 kW
p.2 ↗ |
2BH7220-0AH56-1, 50 Hz |
| Rated pressure (vacuum) |
-500 mbar
p.2 ↗ |
2BH7220-0AH56-1, 60 Hz |
| Max. differential pressure |
740 mbar
p.2 ↗ |
2BH7220-0AH56-1, 60 Hz |
| Sound pressure level |
63 dB(A)
p.2 ↗ |
2BH7220-0AH56-1, 60 Hz |
| Weight |
29 kg
p.2 ↗ |
2BH7220-0AH56-1, 60 Hz |
| Power |
1.75 kW
p.2 ↗ |
2BH7220-0AH56-1, 60 Hz |
| Protection category |
IP 55
p.1 ↗ |
standard motors |
Operating Limits
- Max. ambient/suction temperature for stated total pressure differences: 25 °C
p.1 ↗
- Performance curve tolerance: ± 10 %
p.1 ↗
- Frequency tolerance: +/- 2 % maximum
p.2 ↗
- Protection category: IP 55
p.1 ↗
- Insulation class: F
p.1 ↗
- Converter input voltage (standard motor insulation): up to 460 V
p.2 ↗
Type Code Decoder
| Position |
Token |
Meaning |
| 1-7
p.2 ↗ |
2BH7220 |
Type/size designation (side channel blower, series 2BH7, size 220) |
| 8-9
p.2 ↗ |
-0 |
Fixed separator/version field |
| 13-14
p.2 ↗ |
-1 / -7 |
Suffix: -1 for 50/60 Hz standard, -7 for alternate-voltage motor |
Ordering Data
| Ordering Code |
Part No. |
Variant / Code |
Applies To |
Note |
| 2BH7220-0AH26-1
p.2 ↗ |
2BH7220-0AH26-1 |
H6 |
50/60 Hz, 200-240/345-415 V (50 Hz), 220-275/380-480 V (60 Hz) |
Standard motor, 0.81 kW at 50 Hz |
| 2BH7220-0AH56-1
p.2 ↗ |
2BH7220-0AH56-1 |
H5 |
50/60 Hz, 200-240/345-415 V (50 Hz), 220-275/380-480 V (60 Hz) |
Standard motor, 1.50 kW at 50 Hz |
| 2BH7220-0AC23-1
p.2 ↗ |
2BH7220-0AC23-1 |
C3 |
50/60 Hz, 500 Y (50 Hz), 575 Y (60 Hz) |
Fixed-voltage motor |
| 2BH7220-0AC53-1
p.2 ↗ |
2BH7220-0AC53-1 |
C5 |
50/60 Hz, 500 Y (50 Hz), 575 Y (60 Hz) |
Fixed-voltage motor |
| 2BH7220-0AV74-7
p.2 ↗ |
2BH7220-0AV74-7 |
P7 |
50/60 Hz, 350-450 D / 610-725 Y (50 Hz), 400-500 D / 690-725 Y (60 Hz) |
Alternate-voltage motor |
| 2BH7220-0AV75-7
p.2 ↗ |
2BH7220-0AV75-7 |
P5 |
50/60 Hz, 450-550 D (50 Hz), 520-600 D (60 Hz) |
Alternate-voltage motor |