Elmo Rietschle 2BH7220
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle 2BH7220

Elmo Rietschle 2BH7220 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -370 mbar, Motor power 0.94 kW, Noise level 58 dB.

The 2BH7220 is a side-channel (regenerative) blower in Elmo Rietschle's G-BH7 series, built as a single-stage, directly driven unit with a 1.75 kW motor and IP55 protection. It delivers up to 490 mbar gauge pressure or -370 mbar vacuum, positioning it as the mid-range 220 frame size between the smaller 2BH7210 and larger 2BH7310 siblings. Its primary role is to provide oil-free, pulsation-free air for vacuum holding, aeration, or low-pressure transport in industrial systems.

Max. differential pressure
-370 mbar
Motor power
0.94 kW
Noise level
58 dB
Pumping speed
480 m³/h
Weight
24 kg

Elmo Rietschle G-BH7 Series — Model Comparison & Selection

Model Motor power, kWNoise level, dBMax. differential pressure, mbarWeight, kgCurrent, AVoltage, V
2BH7220 Current 0.8158-440244220-275 / 380-480 Y
2BH721 159-300214.2190–210
2BH7210 0.6363-270163.0 △ / 1.7 Y220-275 △ / 380-480 Y
2BH722 1.158480284.8 UU / 2.4 U190-210 UU / 380-420 U
2BH731 1.163-340242.8–5.5190-210 / 380-420
2BH7310 0.6358250—2.8200-240 / 345-415 Y
2BH732 1.364440333.2190-210 / 380-420
2BH7320 3.577-510486.5—
2BH741 1.363—266.3190–210
2BH7410 2.673-230335.2400
2BH742 1.864460383.9–7.8190-210 / 380-420
2BH7420 2.977-270456.5380
2BH751 1.868-340337.8 UU190-210 UU / 380-420 U
2BH7510 6.6784304312.7400
2BH752 2.564-5205012190-210 / 380-420
2BH7520 4.377-520578.7400 V (-15%) … 480 V (+1
2BH753 5.3699507217.1190–210
2BH7530 7.570-6108016.2400
2BH7610 5.880-4105512.7380
2BH7620 8.879-5307716.2400
2BH7630 1680-50012129400

Full specifications

Core Performance & Functional Specifications
Max. differential pressure -370 mbar (50 Hz)
60 Hz: -440 mbar
Motor power 0.81 kW (50 Hz)
60 Hz: 0.94 kW
Noise level 58 dB (50 Hz)
60 Hz: 63 dB
Pumping speed 490 m³/hour (50 Hz)
60 Hz: 480 m³/hour
Protection category mfr IP55
Rated pressure (vacuum) mfr -370 mbar (50 Hz)
Rated pressure (vacuum) mfr -440 mbar (60 Hz)
Max. differential pressure (vacuum) mfr 490 mbar (50 Hz)
Max. differential pressure (vacuum) mfr 480 mbar (60 Hz)
Order No. mfr 2BH7220-0AH26-1
Dimensions, Weight & Mechanical Design
Weight 24 kg
Electrical, Power & Drive Specifications
Current 4.0 A (50 Hz)
60 Hz: 4.0 / 2.3 Y A
Voltage 200-240 V (50 Hz)
60 Hz: 220-275 / 380-480 Y V
Rated voltage mfr 220-275 Δ / 380-480 Y V (60 Hz)
Rated power mfr 1.75 kW (50 Hz)
Rated power mfr 1.75 kW (60 Hz)
Frequency mfr 60 Hz
Operating Conditions, Environment & Protection
Sound pressure level mfr 58 dB(A) (50 Hz)
Sound pressure level mfr 63 dB(A) (60 Hz)

Description

Construction and series positioning

Performance behaviour

Electrical and control specifics

Integration & Operating Notes

Electrical
Dual-voltage winding requires correct link configuration

The motor terminal box must be wired for either delta (200–240 V at 50 Hz) or star (345–415 V at 50 Hz) according to the supply voltage. Incorrect link placement will apply wrong voltage per winding and can destroy the motor. Verify the connection diagram on the motor nameplate before energising.

Technical Data Sheet — G-BH7 2BH7220 vacuum pump (EN), Edition 07/2021
Maintenance
Periodic bearing and filter inspection required

Although the blower is oil-free, the motor bearings are grease-lubricated for life under normal conditions. Inspect and replace intake filters (if fitted) regularly to prevent clogging, which reduces flow and increases motor load. Check for unusual noise or vibration indicating bearing wear.

Technical Data Sheet — G-BH7 2BH7220 vacuum pump (EN), Edition 07/2021

Selection & Integration Q&A

When should I choose the 2BH7220 instead of a smaller or larger model in the G-BH7 series?

Choose the 2BH7220 when your process needs up to 490 mbar pressure or -370 mbar vacuum at flows within its mid-range capacity. For lower pressure/vacuum or smaller flows, the 2BH7210 is more compact; for higher flows at similar pressures, the 2BH7310 offers greater capacity.

What are the requirements for the electrical supply and protection when connecting this blower?

The motor must be wired for the available supply: delta for 200–240 V (50 Hz) or 220–275 V (60 Hz), star for 345–415 V (50 Hz) or 380–480 V (60 Hz). Use a motor protection switch set to 4.0 A (delta) or 2.3 A (star) and ensure the supply can handle the starting current of a 1.75 kW induction motor.

What maintenance items and accessories are not included in the base delivery?

The base blower includes the motor and impeller but excludes intake filters, silencers, pressure relief valves, flexible connectors, and mounting feet. These must be ordered separately. Regular maintenance includes checking/replacing filters and verifying bearing condition; no oil changes are needed.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — G-BH7 2BH7220 vacuum pump (EN)
Datasheet ·337,1 КБ ·2 pp.
View PDF