Technical Data Sheet — G-BH7 2BH7610 side channel blower (EN)
Technical Reference Summary
Covered Models & Document Scope
Data sheet 2BH7 610-0A: side channel blower with integrated frequency converter (IP55), G-BH7 e series. Covers 50 Hz and 87 Hz (VFD) operation, 400 V Δ connection, and VFD accessory items.
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Rated mains voltage | 400 V p.2 ↗ | 2BH7610-0A, 50 Hz, Δ connection |
| Rated motor current | 12,7 A p.2 ↗ | 2BH7610-0A, 50 Hz, 400 V Δ |
| Rated motor power | 6,6 kW p.2 ↗ | 2BH7610-0A, 50 Hz |
| Max. differential pressure vacuum | -410 mbar p.2 ↗ | 2BH7610-0A, 50 Hz |
| Max. differential pressure pressure | 350 mbar p.2 ↗ | 2BH7610-0A, 50 Hz |
| Sound level | 75/76 dB(A) p.2 ↗ | 2BH7610-0A, 50 Hz |
| Weight | 53 kg p.2 ↗ | 2BH7610-0A, 50 Hz |
| Rated mains voltage | 400 V p.2 ↗ | 2BH7610-0A, 87 Hz, Δ connection |
| Rated motor current | 14,4 A p.2 ↗ | 2BH7610-0A, 87 Hz, 400 V Δ |
| Rated motor power | 7,5 kW p.2 ↗ | 2BH7610-0A, 87 Hz |
| Max. differential pressure vacuum | -440 mbar p.2 ↗ | 2BH7610-0A, 87 Hz |
| Max. differential pressure pressure | 630 mbar p.2 ↗ | 2BH7610-0A, 87 Hz |
| Sound level | 79 dB(A) p.2 ↗ | 2BH7610-0A, 87 Hz |
| Weight | 54 kg p.2 ↗ | 2BH7610-0A, 87 Hz |
| Frequency converter rated mains voltage | 400 V p.2 ↗ | VFD type E, 2FC4552-1□□00 |
| Frequency converter max. motor current | 13,0 A p.2 ↗ | VFD type E, 2FC4552-1□□00 |
| Frequency converter typical motor power | 5,5 kW p.2 ↗ | VFD type E, 2FC4552-1□□00 |
| Frequency converter rated mains current | 10,8 A p.2 ↗ | VFD type E, 2FC4552-1□□00 |
| Frequency converter fuse protection | 20 A p.2 ↗ | VFD type E, 2FC4552-1□□00 |
| Frequency converter weight | 3,9 kg p.2 ↗ | VFD type E, 2FC4552-1□□00 |
Operating Limits
- Max. suction and ambient temperature for stated pressure differences: 25 °C p.1 ↗
- Performance curve tolerance: ± 10 % p.1 ↗
- Minimum frequency converter pulse frequency: 4 kHz p.1 ↗
- Minimum mains voltage for frequency converter: 380 V p.1 ↗
- Rated voltage/frequency set point: 345 V / 87 Hz p.1 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-7 p.2 ↗ | 2BH7610 | Blower type/size designation (2BH7 series, size 610) |
| 8-9 p.2 ↗ | -0A | Version/variant field |
| 10-12 p.2 ↗ | 321 / 326 / K16 / K26 / K46 | Motor/voltage/frequency variant code (e.g. 321 = 400 V Δ 50 Hz; 326 = 380 V 50 Hz; K16/K26/K46 = VFD 87 Hz variants) |
| 13-14 p.2 ↗ | -2 | Suffix / revision |
| VFD field p.2 ↗ | A / B / C / D / E / F / G / H / J / K | Frequency converter size code (2FC4xxx-1□□00) |
Ordering Data
| Ordering Code | Part No. | Variant / Code | Applies To | Note |
|---|---|---|---|---|
| 2BH7610-0A321-2 p.2 ↗ | 2BH7610-0A321-2 | 50 Hz, 400 V Δ | Blower with VFD type E | |
| 2BH7610-0A326-2 p.2 ↗ | 2BH7610-0A326-2 | 50 Hz, 380 V | ||
| 2BH7610-0AK16-2 p.2 ↗ | 2BH7610-0AK16-2 | 87 Hz VFD, 400 V Δ | VFD variant | |
| 2BH7610-0AK26-2 p.2 ↗ | 2BH7610-0AK26-2 | 87 Hz VFD, 400 V Δ | VFD variant | |
| 2BH7610-0AK46-2 p.2 ↗ | 2BH7610-0AK46-2 | 87 Hz VFD, 400 V Δ | VFD variant | |
| 2FX4521-0ER00 p.2 ↗ | 2FX4521-0ER00 | USB adaptor cable | ||
| 2FX6022-0BD00 p.2 ↗ | 2FX6022-0BD00 | Vacuum -1000 … 0 mbar | Differential pressure transmitter |