Technical Data Sheet — SVT 1000 vacuum pump (DE)
Technical Reference Summary
Covered Models & Document Scope
SVT 1000 / S-SVT 1000 oil-flooded twin-screw variable-frequency-controlled screw vacuum pump; compact drive version SVT 1000 IE3 15 with 3 AC 400 V ±10 % motor and frequency converter (15–120 Hz)
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Nominal suction capacity | 892 m³/h p.1 ↗ | S-SVT 1000 |
| Ultimate vacuum (standard) | 0.1 mbar (abs.) p.1 ↗ | S-SVT 1000 |
| Average noise level | 78 ± 3 dB(A) p.1 ↗ | EN ISO 3744 |
| Max. weight without motor | 765 kg p.1 ↗ | incl. oil filling |
| Oil capacity | 22 l p.1 ↗ | |
| Motor power | 15 kW p.1 ↗ | SVT 1000 IE3 |
| Mains voltage | 3 AC 400 V ±10 % V p.1 ↗ | SVT 1000 IE3 |
| Mains frequency | 20 – 115 Hz p.1 ↗ | SVT 1000 IE3 |
| Rotational speed | 1400 - 6780 min⁻¹ p.1 ↗ | SVT 1000 IE3 |
| Mains current | Imax 34.5 A p.1 ↗ | SVT 1000 IE3 |
| Weight | 198 kg p.1 ↗ | SVT 1000 IE3 motor |
| Ambient temperature | 5 to 40 (max. 46 for continuous operation) °C p.1 ↗ | |
| Length | 1583 mm p.2 ↗ | |
| Width | 780 mm p.2 ↗ | |
| Height | 1057 mm p.2 ↗ | |
| Inlet connection | G1/4 p.2 ↗ |
Operating Limits
- Ambient temperature: 5 °C to 40 °C p.1 ↗
- Max ambient temperature for continuous operation: 46 °C p.1 ↗
- Ultimate vacuum: 0.1 mbar (abs.) p.1 ↗
- Mains frequency range: 20 – 115 Hz p.1 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-3 p.1 ↗ | SVT | Screw vacuum pump series |
| 4-7 p.1 ↗ | 1000 | Size / model designation |
| power field p.1 ↗ | 15 | Motor power 15 kW |
| voltage field p.1 ↗ | 3 AC 400 V ±10 % | Mains voltage |
| frequency field p.1 ↗ | 20 – 115 Hz | Mains frequency range |