Elmo Rietschle SVT
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle SVT

Elmo Rietschle SVT — Screw Vacuum Pumps with Motor power 15 kW, Pumping speed 892 m³/h, Ultimate pressure 0.1 mbar.

The SVT is an oil-injected twin-screw vacuum pump with integrated variable-frequency control, delivering 892 m³/h pumping speed and 0.1 mbar ultimate pressure from a 15 kW motor. Its 1400–6780 rpm speed range distinguishes it within the SVT series, enabling demand-based throughput. It serves continuous vacuum generation in industrial processes requiring stable low-pressure performance.

Motor power
15 kW
Pumping speed
892 m³/h
Ultimate pressure
0.1 mbar

Full specifications

Core Performance & Functional Specifications
Lubrication type oil-lubricated
Motor power 15 kW
Operating principle Twin-screw, oil-injected, variable-frequency controlled
Pumping speed 892 m³/h
Ultimate pressure 0.1 mbar
Rotational speed 1400 - 6780 rpm
Dimensions, Weight & Mechanical Design
Weight 765 kg
Weight (alt var) mfr 198 kg
Electrical, Power & Drive Specifications
Power supply 3 AC 400 V ±10 %
Materials, Media & Process Compatibility
Oil capacity 22 l
Operating Conditions, Environment & Protection
Noise level 78 ± 3 dB
Ambient temperature limit 5 to 40 (max 46 for continuous operation) °C

Description

Construction and positioning

Behavior under load and media

Installation, control and operation

Integration & Operating Notes

Mounting
Suction port torque must not exceed 100 Nm

Over-tightening the suction connection can crack the pump housing or distort the inlet flange. Use a torque wrench and tighten the discharge port by hand only to avoid damage.

Operating Instructions, Section 6.5.1 / p.17
Control & I/O
START devices must be adjacent to STOP devices with priority

Control stations must comply with EN 418 or IEC 417; each START must be located close to a STOP that takes priority. After a STOP or fault, restart only via a deliberately carried out procedure to prevent unexpected start-up.

Operating Instructions, Section 6.6 / p.18
Environment
Ambient above 40 °C limits continuous operation to 46 °C maximum

Standard ambient range is 5–40 °C; continuous operation is permitted up to 46 °C. Above these limits, motor and converter overheating may occur. For outdoor installation, provide protection against rain, sunlight, snow and icing.

Factory Specification Sheet; Operating Instructions, Section 6.3 / p.15

Selection & Integration Q&A

When should I choose the SVT 1000 over other SVT series models?

Choose SVT 1000 for 892 m³/h at 0.1 mbar with 15 kW. Larger siblings (SVT1500+) suit higher flow; smaller (SVT600/800) suit lower flow. The integrated VFC enables demand-based speed control from 1400–6780 rpm, avoiding external drives.

What are the requirements for the electrical supply and motor protection?

Supply 3 AC 400 V ±10 %, 50/60 Hz. Use a motor protection switch set to the nameplate rated current and follow IEC 60204-1.

Can the SVT be installed outdoors and what are the duty-cycle limits?

Yes, indoors or outdoors with protection against rain, sunlight, snow and icing. Install horizontally on a level, rigid surface; floor-level needs no fastening but secure against falling. Ambient 5–40 °C; continuous operation permitted up to 46 °C maximum. Not for ATEX areas.

What maintenance items and accessories are not included in the base delivery?

Base unit excludes check valve, level sensor LS-7, pressure switch, solenoid valve, thermostatic mixer (not for stainless steel), and cavitation protection. Plan bearing service every 2.5 years/20,000 h.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Operating Instructions — (DE)
Manual ·1,9 МБ ·38 pp.
View PDF
PDF
Operating Instructions — (EN)
Manual ·1,8 МБ ·38 pp.
View PDF
PDF
Technical Data Sheet — SVT 1000 vacuum pump (DE)
Datasheet ·205,0 КБ ·3 pp.
View PDF
PDF
IR ER SVT Series Brochure 12pp LR
Datasheet ·3,2 МБ ·7 pp.
View PDF