Operating Instructions — (EN)
Technical Reference Summary
Covered Models & Document Scope
L-BV3 series liquid-ring vacuum pumps/compressors, model 2BV3151. Covers transport, installation, electrical connection, pipe/hose connection, commissioning, operation (self-priming and operating-liquid feed, non-automatic and automatic), shut-down, servicing and troubleshooting. Electrical data per drive motor rating plate; special models may have higher weights.
Section-by-Section Technical Breakdown
Mechanical data, tightening torques, electrical data reference and operating conditions for the 2BV3151. Includes weight, minimum heat-dissipation distance, noise level, temperature and pressure limits, and liquid quantities.
- Weight approx. 9 kg (19.8 lbs); higher weights possible with special models.
- Minimum distance from fan guard to adjacent surface: 20 mm (0.787 in).
- 1-m measuring-surface sound pressure level: 70 dB(A) at 50 Hz and 70 dB(A) at 60 Hz.
- Operating speed: see rating plate; exceeding it increases noise, vibration and reduces bearing/grease life.
- Tightening torques: G1/8 pipe connections 4.5 Nm ±10%; G3/8 pipe connections 16 Nm ±10%; M4 terminal board 1.0 Nm; M5 terminal board 2.2 Nm; M3 modular terminal blocks 0.6 Nm.
- Pumped gas/vapor temperature max. +110 °C (+230 °F); operating-liquid temperature +5 to +40 °C (nominal +15 °C); ambient temperature +5 to +40 °C.
- Min. inlet pressure during vacuum operation without cavitation protection: 5 kPa (0.725 psi); with cavitation protection: max. achievable vacuum.
- Max. discharge pressure during vacuum operation: 110 kPa abs. (16.0 psia); max. differential pressure during compressor operation: 60 kPa (8.70 psi); max. permissible internal pressure during compressor operation: 300 kPa abs. (43.5 psia).
- Nominal operating-liquid flow rate: 0.65 l/min (0.039 m³/h); max. filling quantity at standstill: 0.200 l; max. water entrained via inlet: 3.9 l/min.
Describes the two main operating modes: self-priming operation and operation with operating-liquid feed, the latter subdivided into non-automatic (manual stop valve) and automatic (solenoid valve linked to motor) operation.
- Self-priming operation: pump automatically sucks in operating liquid; flow rate self-adjusts.
- Operation with operating-liquid feed: operating liquid is not self-primed; a nominal flow rate or pre-pressure must be set.
- Non-automatic operation: operating-liquid feed switched manually with a stop valve.
- Automatic operation: solenoid valve opens when motor is switched on and closes when motor is switched off.
Covers mechanical installation, electrical connection of the motor, and connection of pipes/hoses for inlet, discharge and operating liquid. Includes minimum distances, vibration limits, electrical clearances and tightening torques.
- Install on flat, level, stationary surfaces at max. 1000 m (3280 ft) above sea level.
- Maintain minimum distance of 20 mm from fan guard to adjacent surface; do not re-suck discharge air of other units.
- Maximum permissible vibration velocity veff = 4.5 mm/s (0.177 in/s).
- Secure all feet with screws through all mounting holes.
- Electrical supply tolerances: ±5% voltage deviation, ±2% frequency deviation.
- Clearance between bare live parts and to ground: ≥5.5 mm at UN ≤690 V.
- Use motor circuit breakers set to the nominal current on the rating plate.
- Pipe connections: inlet G3/8 (12 mm deep), discharge G3/8 (12 mm deep), operating-liquid port G1/8 (10 mm deep), cavitation protection G1/8 (10 mm deep), drain hole G1/8 (10 mm deep).
- Tightening torque for G3/8 intake and discharge connections must not exceed 16 Nm ±10%.
- Install a check valve when connecting to a vacuum accumulator.
- Install a start-up screen in the inlet pipe for the first 100 operating hours.
Preparation and start-up procedures for self-priming operation and operation with operating-liquid feed. Includes filling with operating liquid, checking direction of rotation, and setting operating-liquid flow rate.
- Do not switch on unless the unit is filled with operating liquid; dry running destroys the mechanical seal in seconds.
- For self-priming operation, fill operating liquid during installation before connecting pipes/hoses.
- For operation with operating-liquid feed, fill after completing installation via the cavitation protection hole.
- Check direction of rotation by briefly switching on and comparing external fan rotation with the arrow on the housing.
- Self-priming operation: inlet must be pre-throttled to at least 80 kPa abs. (11.6 psia) at switch-on; liquid level at switch-on must equal shaft center; during operation reservoir level may not drop below approx. 1 m (3.28 ft) below shaft center.
- Operation with operating-liquid feed: set pre-pressure pA ≈ pB + 100 kPa (14.5 psi) above inlet pressure, or measure and set flow rate via flow meter or graduated vessel.
- Nominal operating-liquid flow rate: 0.65 l/min.
Maintenance and repair/troubleshooting content. Includes a fault table with symptoms, causes, remedies and who may carry out the work.
- Fault table covers motor not starting, humming noises, jammed impeller, defective impeller and defective motor bearings.
- Electrical faults must be remedied by an electrician; mechanical faults by operator or service as indicated.
- Decalcification and cleaning procedures are referenced to Chapter 10.1, Maintenance, Pg. 24.
Key Integration, Operating & Safety Requirements
| Specification / Condition | Engineering Implication | Applies To |
|---|---|---|
| Weight of 2BV3151 is approx. 9 kg (19.8 lbs); higher weights possible with special models. | Verify load-bearing capacity of installation surface and select lifting equipment accordingly. | 2BV3151 |
| Minimum distance from fan guard to adjacent surface is 20 mm (0.787 in). | Maintain clearance to ensure sufficient cooling and prevent overheating. | 2BV3151 |
| 1-m measuring-surface sound pressure level is 70 dB(A) at both 50 Hz and 60 Hz. | Use for acoustic planning and hearing protection assessment. | 2BV3151 |
| Tightening torques: G1/8 pipe connections 4.5 Nm ±10%; G3/8 pipe connections 16 Nm ±10%; M4 terminal board 1.0 Nm; M5 terminal board 2.2 Nm; M3 modular terminal blocks 0.6 Nm. | Use correct torque to avoid leakage or damage to connections. | 2BV3151 |
| Pumped gas/vapor temperature max. +110 °C (+230 °F); operating-liquid temperature +5 to +40 °C (nominal +15 °C); ambient temperature +5 to +40 °C. | Ensure process and ambient conditions stay within these limits; at >80 °C consider increased operating-liquid flow or series capacitor. | 2BV3151 |
| Min. inlet pressure during vacuum operation without cavitation protection: 5 kPa (0.725 psi); with cavitation protection: max. achievable vacuum. | Do not operate below 5 kPa abs. without cavitation protection to avoid cavitation damage. | 2BV3151 |
| Max. discharge pressure during vacuum operation: 110 kPa abs. (16.0 psia); max. differential pressure during compressor operation: 60 kPa (8.70 psi); max. permissible internal pressure during compressor operation: 300 kPa abs. (43.5 psia). | Provide protective devices if system pressures can exceed these limits. | 2BV3151 |
| Nominal operating-liquid flow rate: 0.65 l/min (0.039 m³/h); max. filling quantity at standstill: 0.200 l; max. water entrained via inlet: 3.9 l/min. | Set operating-liquid flow to nominal value; install upstream separator if entrained water can exceed 3.9 l/min. | 2BV3151 |
| Maximum permissible vibration velocity veff = 4.5 mm/s (0.177 in/s). | Ensure installation and system vibrations do not exceed this value for proper operation and long service life. | 2BV3151 |
| Electrical supply tolerances: ±5% voltage deviation and ±2% frequency deviation permissible without reduction in performance. | Verify supply quality; larger deviations may require consultation with Service Department. | 2BV3151 |
| Clearance between bare live parts and between bare live parts and ground: ≥5.5 mm at nominal voltage UN ≤690 V. | Maintain minimum electrical clearance during wiring to ensure safety. | 2BV3151 |
| Pipe connections: inlet G3/8 (12 mm deep), discharge G3/8 (12 mm deep), operating-liquid port G1/8 (10 mm deep), cavitation protection G1/8 (10 mm deep), drain hole G1/8 (10 mm deep). | Select mating fittings and pipes accordingly. | 2BV3151 |
| Tightening torque for G3/8 intake and discharge connections must not exceed 16 Nm ±10% (11.8 ft lbs ±10%). | Avoid over-tightening to prevent damage to connections. | 2BV3151 |
| Self-priming operation requires inlet pre-throttled to at least 80 kPa abs. (11.6 psia) at switch-on; liquid level at switch-on must equal shaft center; during operation reservoir level may not drop below approx. 1 m (3.28 ft) below shaft center. | Design feed pipe and reservoir to meet these levels for reliable self-priming. | 2BV3151 |
| Operation with operating-liquid feed: set pre-pressure pA ≈ pB + 100 kPa (14.5 psi) above inlet pressure, or measure and set flow rate via flow meter or graduated vessel. | Use method A or B to establish correct operating-liquid flow. | 2BV3151 |
| Install a check valve when connecting the pump to a vacuum accumulator. | Prevents operating liquid from being sucked into the system. | 2BV3151 |
| Install a start-up screen in the inlet pipe for the first 100 operating hours. | Prevents installation residues from entering the unit. | 2BV3151 |
| Use motor circuit breakers set to the nominal current specified on the rating plate. | Provides correct motor overload protection. | 2BV3151 |
Faults & Troubleshooting
| Code / Symptom | Possible Cause | Remedy | Note |
|---|---|---|---|
| Motor does not start, no running noise. p.26 ↗ | Interruption of the power supply, with single-phase model in one cable, with two-phase model in at least two cables. | Check fuses, terminals and cables for open circuit. Eliminate open circuit. | Carried out by: Electrician |
| Motor does not start, humming noises. p.26 ↗ | One power supply lead interrupted. | Check fuses, terminals and cables for open circuit. Eliminate open circuit. | Carried out by: Electrician |
| Impeller is jammed. p.26 ↗ | Impeller is jammed. | Free shaft by turning. See Chapter 10.1, "Maintenance", Pg. 24. | Carried out by: Operator |
| Impeller is jammed. p.26 ↗ | Impeller is jammed. | Decalcify vacuum pump/compressor. See Chapter 10.1, "Maintenance", Pg. 24. | Carried out by: Operator |
| Impeller is jammed. p.26 ↗ | Impeller is jammed. | Drain and clean vacuum pump/compressor if necessary. See Chapter 10.1, "Maintenance", Pg. 24. | Carried out by: Operator |
| Impeller is jammed. p.26 ↗ | Impeller is jammed. | Check and correct impeller gap setting if necessary. | Carried out by: Service |
| Impeller defective. p.26 ↗ | Impeller defective. | Replace impeller. | Carried out by: Service |
| Motor bearings defective. p.26 ↗ | Motor bearings defective. | Replace motor bearings. | Carried out by: Service |