Operating Instructions — (EN)

Technical Reference Summary

Covered Models & Document Scope

L-BV3 series liquid-ring vacuum pumps/compressors, model 2BV3151. Covers transport, installation, electrical connection, pipe/hose connection, commissioning, operation (self-priming and operating-liquid feed, non-automatic and automatic), shut-down, servicing and troubleshooting. Electrical data per drive motor rating plate; special models may have higher weights.

Section-by-Section Technical Breakdown

pp. 7-8
Technical Data

Mechanical data, tightening torques, electrical data reference and operating conditions for the 2BV3151. Includes weight, minimum heat-dissipation distance, noise level, temperature and pressure limits, and liquid quantities.

  • Weight approx. 9 kg (19.8 lbs); higher weights possible with special models.
  • Minimum distance from fan guard to adjacent surface: 20 mm (0.787 in).
  • 1-m measuring-surface sound pressure level: 70 dB(A) at 50 Hz and 70 dB(A) at 60 Hz.
  • Operating speed: see rating plate; exceeding it increases noise, vibration and reduces bearing/grease life.
  • Tightening torques: G1/8 pipe connections 4.5 Nm ±10%; G3/8 pipe connections 16 Nm ±10%; M4 terminal board 1.0 Nm; M5 terminal board 2.2 Nm; M3 modular terminal blocks 0.6 Nm.
  • Pumped gas/vapor temperature max. +110 °C (+230 °F); operating-liquid temperature +5 to +40 °C (nominal +15 °C); ambient temperature +5 to +40 °C.
  • Min. inlet pressure during vacuum operation without cavitation protection: 5 kPa (0.725 psi); with cavitation protection: max. achievable vacuum.
  • Max. discharge pressure during vacuum operation: 110 kPa abs. (16.0 psia); max. differential pressure during compressor operation: 60 kPa (8.70 psi); max. permissible internal pressure during compressor operation: 300 kPa abs. (43.5 psia).
  • Nominal operating-liquid flow rate: 0.65 l/min (0.039 m³/h); max. filling quantity at standstill: 0.200 l; max. water entrained via inlet: 3.9 l/min.
pp. 9
Operating Modes

Describes the two main operating modes: self-priming operation and operation with operating-liquid feed, the latter subdivided into non-automatic (manual stop valve) and automatic (solenoid valve linked to motor) operation.

  • Self-priming operation: pump automatically sucks in operating liquid; flow rate self-adjusts.
  • Operation with operating-liquid feed: operating liquid is not self-primed; a nominal flow rate or pre-pressure must be set.
  • Non-automatic operation: operating-liquid feed switched manually with a stop valve.
  • Automatic operation: solenoid valve opens when motor is switched on and closes when motor is switched off.
pp. 11-15
Installation

Covers mechanical installation, electrical connection of the motor, and connection of pipes/hoses for inlet, discharge and operating liquid. Includes minimum distances, vibration limits, electrical clearances and tightening torques.

  • Install on flat, level, stationary surfaces at max. 1000 m (3280 ft) above sea level.
  • Maintain minimum distance of 20 mm from fan guard to adjacent surface; do not re-suck discharge air of other units.
  • Maximum permissible vibration velocity veff = 4.5 mm/s (0.177 in/s).
  • Secure all feet with screws through all mounting holes.
  • Electrical supply tolerances: ±5% voltage deviation, ±2% frequency deviation.
  • Clearance between bare live parts and to ground: ≥5.5 mm at UN ≤690 V.
  • Use motor circuit breakers set to the nominal current on the rating plate.
  • Pipe connections: inlet G3/8 (12 mm deep), discharge G3/8 (12 mm deep), operating-liquid port G1/8 (10 mm deep), cavitation protection G1/8 (10 mm deep), drain hole G1/8 (10 mm deep).
  • Tightening torque for G3/8 intake and discharge connections must not exceed 16 Nm ±10%.
  • Install a check valve when connecting to a vacuum accumulator.
  • Install a start-up screen in the inlet pipe for the first 100 operating hours.
pp. 16-19
Commissioning

Preparation and start-up procedures for self-priming operation and operation with operating-liquid feed. Includes filling with operating liquid, checking direction of rotation, and setting operating-liquid flow rate.

  • Do not switch on unless the unit is filled with operating liquid; dry running destroys the mechanical seal in seconds.
  • For self-priming operation, fill operating liquid during installation before connecting pipes/hoses.
  • For operation with operating-liquid feed, fill after completing installation via the cavitation protection hole.
  • Check direction of rotation by briefly switching on and comparing external fan rotation with the arrow on the housing.
  • Self-priming operation: inlet must be pre-throttled to at least 80 kPa abs. (11.6 psia) at switch-on; liquid level at switch-on must equal shaft center; during operation reservoir level may not drop below approx. 1 m (3.28 ft) below shaft center.
  • Operation with operating-liquid feed: set pre-pressure pA ≈ pB + 100 kPa (14.5 psi) above inlet pressure, or measure and set flow rate via flow meter or graduated vessel.
  • Nominal operating-liquid flow rate: 0.65 l/min.
pp. 24-26
Servicing and Troubleshooting

Maintenance and repair/troubleshooting content. Includes a fault table with symptoms, causes, remedies and who may carry out the work.

  • Fault table covers motor not starting, humming noises, jammed impeller, defective impeller and defective motor bearings.
  • Electrical faults must be remedied by an electrician; mechanical faults by operator or service as indicated.
  • Decalcification and cleaning procedures are referenced to Chapter 10.1, Maintenance, Pg. 24.

Key Integration, Operating & Safety Requirements

Specification / Condition Engineering Implication Applies To
Weight of 2BV3151 is approx. 9 kg (19.8 lbs); higher weights possible with special models. Verify load-bearing capacity of installation surface and select lifting equipment accordingly. 2BV3151
Minimum distance from fan guard to adjacent surface is 20 mm (0.787 in). Maintain clearance to ensure sufficient cooling and prevent overheating. 2BV3151
1-m measuring-surface sound pressure level is 70 dB(A) at both 50 Hz and 60 Hz. Use for acoustic planning and hearing protection assessment. 2BV3151
Tightening torques: G1/8 pipe connections 4.5 Nm ±10%; G3/8 pipe connections 16 Nm ±10%; M4 terminal board 1.0 Nm; M5 terminal board 2.2 Nm; M3 modular terminal blocks 0.6 Nm. Use correct torque to avoid leakage or damage to connections. 2BV3151
Pumped gas/vapor temperature max. +110 °C (+230 °F); operating-liquid temperature +5 to +40 °C (nominal +15 °C); ambient temperature +5 to +40 °C. Ensure process and ambient conditions stay within these limits; at >80 °C consider increased operating-liquid flow or series capacitor. 2BV3151
Min. inlet pressure during vacuum operation without cavitation protection: 5 kPa (0.725 psi); with cavitation protection: max. achievable vacuum. Do not operate below 5 kPa abs. without cavitation protection to avoid cavitation damage. 2BV3151
Max. discharge pressure during vacuum operation: 110 kPa abs. (16.0 psia); max. differential pressure during compressor operation: 60 kPa (8.70 psi); max. permissible internal pressure during compressor operation: 300 kPa abs. (43.5 psia). Provide protective devices if system pressures can exceed these limits. 2BV3151
Nominal operating-liquid flow rate: 0.65 l/min (0.039 m³/h); max. filling quantity at standstill: 0.200 l; max. water entrained via inlet: 3.9 l/min. Set operating-liquid flow to nominal value; install upstream separator if entrained water can exceed 3.9 l/min. 2BV3151
Maximum permissible vibration velocity veff = 4.5 mm/s (0.177 in/s). Ensure installation and system vibrations do not exceed this value for proper operation and long service life. 2BV3151
Electrical supply tolerances: ±5% voltage deviation and ±2% frequency deviation permissible without reduction in performance. Verify supply quality; larger deviations may require consultation with Service Department. 2BV3151
Clearance between bare live parts and between bare live parts and ground: ≥5.5 mm at nominal voltage UN ≤690 V. Maintain minimum electrical clearance during wiring to ensure safety. 2BV3151
Pipe connections: inlet G3/8 (12 mm deep), discharge G3/8 (12 mm deep), operating-liquid port G1/8 (10 mm deep), cavitation protection G1/8 (10 mm deep), drain hole G1/8 (10 mm deep). Select mating fittings and pipes accordingly. 2BV3151
Tightening torque for G3/8 intake and discharge connections must not exceed 16 Nm ±10% (11.8 ft lbs ±10%). Avoid over-tightening to prevent damage to connections. 2BV3151
Self-priming operation requires inlet pre-throttled to at least 80 kPa abs. (11.6 psia) at switch-on; liquid level at switch-on must equal shaft center; during operation reservoir level may not drop below approx. 1 m (3.28 ft) below shaft center. Design feed pipe and reservoir to meet these levels for reliable self-priming. 2BV3151
Operation with operating-liquid feed: set pre-pressure pA ≈ pB + 100 kPa (14.5 psi) above inlet pressure, or measure and set flow rate via flow meter or graduated vessel. Use method A or B to establish correct operating-liquid flow. 2BV3151
Install a check valve when connecting the pump to a vacuum accumulator. Prevents operating liquid from being sucked into the system. 2BV3151
Install a start-up screen in the inlet pipe for the first 100 operating hours. Prevents installation residues from entering the unit. 2BV3151
Use motor circuit breakers set to the nominal current specified on the rating plate. Provides correct motor overload protection. 2BV3151

Faults & Troubleshooting

Code / Symptom Possible Cause Remedy Note
Motor does not start, no running noise. p.26 ↗ Interruption of the power supply, with single-phase model in one cable, with two-phase model in at least two cables. Check fuses, terminals and cables for open circuit. Eliminate open circuit. Carried out by: Electrician
Motor does not start, humming noises. p.26 ↗ One power supply lead interrupted. Check fuses, terminals and cables for open circuit. Eliminate open circuit. Carried out by: Electrician
Impeller is jammed. p.26 ↗ Impeller is jammed. Free shaft by turning. See Chapter 10.1, "Maintenance", Pg. 24. Carried out by: Operator
Impeller is jammed. p.26 ↗ Impeller is jammed. Decalcify vacuum pump/compressor. See Chapter 10.1, "Maintenance", Pg. 24. Carried out by: Operator
Impeller is jammed. p.26 ↗ Impeller is jammed. Drain and clean vacuum pump/compressor if necessary. See Chapter 10.1, "Maintenance", Pg. 24. Carried out by: Operator
Impeller is jammed. p.26 ↗ Impeller is jammed. Check and correct impeller gap setting if necessary. Carried out by: Service
Impeller defective. p.26 ↗ Impeller defective. Replace impeller. Carried out by: Service
Motor bearings defective. p.26 ↗ Motor bearings defective. Replace motor bearings. Carried out by: Service