Elmo Rietschle L-2BV 3151
Elmo Rietschle L-2BV 3151 — Liquid Ring Vacuum Pumps with Max inlet pressure 110 kPa, Pumping speed 39 m³/h.
The L-2BV 3151 is a liquid-ring vacuum pump/compressor in the L-2BV series, factory-rated for vacuum operation to 110 kPa abs. and compressor duty to 300 kPa abs. Its 0.65 l/min nominal operating-liquid flow and 0.200 l standstill fill distinguish this modification from larger siblings such as the L-2BV 7060. It serves as a compact, self-priming vacuum source for processes tolerating a 5 kPa abs. lower limit without cavitation protection.
Elmo Rietschle L-2BV Series — Model Comparison & Selection
| Model | Max inlet pressure, kPa | Operating principle | Weight, kg | Noise level, dB | Operating temperature, °C | Pumping speed, m³/h |
|---|---|---|---|---|---|---|
| L-2BV 3151 Current | 3.3 | — | 9 | 70 | 110 | 39 |
| 2BV3151 | — | Liquid ring vacuum pump | 9 | 70 | — | — |
| L-2BV 7060 | 130 | liquid-ring | 25 | 70 | 80 | — |
Full specifications
| Max inlet pressure | 3.3 kPa vacuum operation without cavitation protection: 5 kPa · vacuum operation: 110 kPa · compressor operation, p1=101.3 kPa abs: 60 kPa · compressor operation: 300 kPa |
| Pumping speed | 0.039 m³/h (dry air extraction, water at 15 °C) |
| Water vapor tolerance | 3.9 l/min |
| Min. inlet pressure p1 min (without cavitation protection) (alt vacuum operation without cavitation protection) mfr | 0.725 psi (vacuum operation without cavitation protection) |
| Max. discharge pressure p2 max (vacuum operation) (alt vacuum operation) mfr | 16.0 psi (vacuum operation) |
| Max. discharge pressure (differential) p2 max (compressor operation) (alt compressor operation, p1=101.3 kPa abs) mfr | 8.70 psi (compressor operation, p1=101.3 kPa abs) |
| Weight | 9 kg |
| Weight (alt var) mfr | 19.8 lb |
| Oil capacity | 0.200 l |
| Max. pre-pressure of operating liquid (alt var) mfr | 300 kPa |
| Noise level | 70 dB (50 Hz) 60 Hz: 70 dB |
| Operating temperature | 110 °C |
| Ambient temperature limit | 40 °C |
Description
Construction and series positioning
- Liquid-ring operating principle with a single rotating impeller in an elliptical casing; the operating liquid forms the sealing ring.
- This model is the smallest in the L-2BV family: 9 kg (19.8 lb) approximate weight, G3/8 inlet and discharge ports, and a 0.200 l maximum standstill operating-liquid charge.
- Sibling 2BV3151 shares the same ultimate pressure (33 mbar abs.) but is listed separately; the L-2BV 7060 is a larger frame with 1.3 bar max inlet pressure. Choose the 3151 when port size and liquid volume must stay minimal.
Behavior under load and media
- Vacuum duty: maximum inlet pressure 110 kPa abs.; without cavitation protection, operation below 5 kPa abs. is not permitted. With cavitation protection, the maximum achievable vacuum applies.
- Compressor duty: maximum internal pressure 300 kPa abs.; maximum differential pressure 60 kPa at p1 = 101.3 kPa abs.
- Pumped gas/vapor temperature up to +110 °C (+230 °F); operating liquid +5 to +40 °C (nominal +15 °C); ambient +5 to +40 °C.
- Water vapor tolerance via inlet: 3.9 l/min; nominal operating-liquid flow 0.65 l/min (0.039 m³/h).
- Noise: 70 dB(A) at 1 m, both 50 and 60 Hz.
Installation, connection and control
- Two operating modes: self-priming and operating-liquid feed (non-automatic via manual stop valve, or automatic via solenoid valve linked to the motor).
- Self-priming requires inlet pre-throttled to at least 80 kPa abs. at switch-on; reservoir level at switch-on must equal shaft center and may not drop below ~1 m below shaft center during operation.
- Operating-liquid feed: set pre-pressure pA ≈ pB + 100 kPa above inlet pressure, or measure flow via flow meter or graduated vessel.
- Electrical: motor circuit breaker set to rating-plate nominal current; supply tolerance ±5% voltage and ±2% frequency; minimum live-part clearance 5.5 mm at UN ≤690 V.
- Piping: G3/8 inlet/discharge (12 mm deep), G1/8 operating-liquid, cavitation-protection and drain ports (10 mm deep); G3/8 torque ≤16 Nm ±10%, G1/8 torque 4.5 Nm ±10%.
Integration & Operating Notes
Operating below 5 kPa absolute during vacuum duty without cavitation protection risks cavitation damage to the liquid ring and impeller. If the process requires deeper vacuum, a cavitation-protection connection (G1/8 port) must be installed and the maximum achievable vacuum per the factory curve applies.
During vacuum operation the maximum discharge pressure is 110 kPa abs. (16.0 psia). In compressor operation the maximum permissible internal pressure is 300 kPa abs. and the maximum differential pressure is 60 kPa at p1 = 101.3 kPa abs. Provide pressure-relief or interlock devices if the system can exceed these values.
The nominal operating-liquid flow is 0.65 l/min (0.039 m³/h). In feed operation, set pre-pressure pA ≈ pB + 100 kPa above inlet pressure, or measure and adjust flow with a flow meter or graduated vessel. Insufficient flow degrades vacuum; excess flow raises power and liquid carry-over.
The pump tolerates up to 3.9 l/min of water entrained through the inlet. If the process can carry more liquid, install an upstream separator to prevent flooding of the liquid ring and loss of vacuum performance.
A minimum distance of 20 mm (0.787 in) between the fan guard and any adjacent surface is required for adequate cooling. Also ensure installation vibration velocity does not exceed 4.5 mm/s (0.177 in/s) to avoid bearing and seal damage.
For self-priming operation, the inlet must be pre-throttled to at least 80 kPa abs. (11.6 psia) at switch-on. The liquid level at switch-on must equal shaft center, and during operation the reservoir level may not drop below approximately 1 m (3.28 ft) below shaft center. Design the feed pipe and reservoir accordingly.
The motor circuit breaker must be set to the nominal current specified on the drive motor rating plate. Supply tolerances of ±5% voltage and ±2% frequency are permissible without performance reduction; larger deviations require consultation with the Service Department.
Clearance between bare live parts, and between bare live parts and ground, must be at least 5.5 mm at nominal voltage UN ≤690 V. Observe terminal-board tightening torques: M4 1.0 Nm, M5 2.2 Nm, M3 modular terminal blocks 0.6 Nm.
Tightening torque for G3/8 intake and discharge connections must not exceed 16 Nm ±10% (11.8 ft·lb ±10%). G1/8 connections (operating liquid, cavitation protection, drain) require 4.5 Nm ±10%.
Selection & Integration Q&A
Choose the 3151 when you need a compact 9 kg pump with G3/8 ports and a 0.200 l liquid charge for vacuum duty to 5 kPa abs. (without cavitation protection) or compressor duty to 300 kPa abs. The 7060 offers higher inlet pressure (1.3 bar) for larger flows; the 2BV3151 shares the same ultimate pressure but is listed separately—verify port and liquid-volume differences before substituting.
Use a motor circuit breaker set to the nominal current on the rating plate. Supply tolerance is ±5% voltage and ±2% frequency. Maintain ≥5.5 mm clearance between live parts and ground at UN ≤690 V. Terminal-board torques: M4 1.0 Nm, M5 2.2 Nm, M3 0.6 Nm.
A start-up screen must be fitted in the inlet pipe for the first 100 operating hours. A check valve is required when connecting to a vacuum accumulator. For automatic operating-liquid feed, a solenoid valve linked to the motor is needed. Cavitation protection requires an external connection to the G1/8 port. Operating liquid (0.200 l max fill) and mating G3/8 fittings are not supplied.