Top Supplies for Agilent 708-DS Dissolution Systems

Contents

  1. Overview pp. 1-2
    Introduction to recommended supplies for 708-DS systems
  2. Config pp. 2-3
    Rotating paddle and basket recommendations with ordering details
  3. Ordering p. 4
    Reference to further supplies catalog for 6-position apparatus
  4. p. 3 table, 16 rows
  5. p. 4 table, 3 rows

Recommended Spare Parts and Consumables for 708-DS

Part NumberDescriptionApparatusReason to UseRecommended Quantity on Lab Safety Stock
14-3613Upper receptor shaft, 21 in. (total length when assembled)708-DS App 1 and 2Easy to corrode1
14-3631Basket shaft, lower interchangeable, 3-clip, USP708-DS App 1Easy to corrode1
12-2100VBasket, USP, 40-mesh (Top Recommendation)708-DS App 1Easy to corrode or bend1
12-2100VBasket, USP, 40-mesh, includes CoA (Top Recommendation)708-DS App 1Easy to corrode or bend, CoA
14-3603Lower interchangeable paddle, electropolished stainless steel, 1 L (Top Recommendation)708-DS App 2Easy to corrode or bend1
14-3609Lower interchangeable paddle, DLC-coated, 1L (Top Recommendation)708-DS App 2The superior Diamond Like Carbon (DLC)-coating can withstand typical Dissolution test and cleaning procedures without getting damaged over time like we see for PTFE-coated paddles1
12-5149VTruAlign vessel, 1 L, clear (Top Recommendation)708-DS App 1 and 2Easy to break or scratch1
12-5149VTruAlign vessel, 1 L, clear, includes CoA (Top Recommendation)708-DS App 1 and 2Easy to break or scratch, CoA1
12-1450TruAlign vessel, 250 mL conversion kit, for Chinese Pharmacopeia (includes vessel, adapter, two-piece mini paddle, evaporation cover and manifold adapter), set of 6708-DS App 2Conversion kit to use small vessels for Chinese Pharmacopeia1
12-3222Bent cannula with adjustable gauge 7.75 in. 708-DS708-DS App 1 and 2Easy to bend, lose, or corrode1
17-4000Full Flow Filter UHMWPE, blue, 10 μm, 100/pk (Top Recommendation)708-DS App 1 and 2One-time use consumables, one per Dissolution test1
17-4005Full Flow Filter UHMWPE, blue, 10 μm, 1000/pk (Top Recommendation)708-DS App 1 and 2One-time use consumables, one per Dissolution test, convenience pack1
12-3000Capsule weight wire, 316 stainless steel, 0.032 in. dia., 50 ft.708-DS App 2Easy to corrode or lose1
12-3050Capsule weight, 3-prong708-DS App 2Easy to break or lose1
12-3070Sinker basket, Japanese Pharmacopoeia (JP)708-DS App 2Easy to bend, lose, or corrode1
G7910-87002Thermal printer paper for use with 708-DS, 10 rolls/pk708-DS App 1and 2Consumable to print report with printer option for 708-DS1

Table

Part NumberDescriptionApparatusReason to UseRecommended Quantity on Lab Safety Stock
5191-5923Syringe filter, PES, 25 mm, 0.45 μm, 1000/pk—The dissolution test requires secondary filtration to avoid secondary dissolution and prevent contamination of the column and system1
5185-5824Cap, screw, blue, bonded pre-slit PTFE/silicone septa, 100/pk. Cap size: 12 mm—Pre-slit septa can prevent the septum from coring when the needle is sampling1
5190-9589A-Line screw top vial, 2 mL, clear, write-on spot, 100/pk. Vial size: 12 x 32 mm (12 mm cap)—The highest purity glass to reduce the interference of metal ions on glass surface with sample1

For more Supplies, please refer to 5994-0388EN: Agilent 708-DS Dissolution Apparatus (6-position/G7910A and 8-position/G7911A) Supplies Quick Reference Guide.

Engineering Facts

12 facts · every claim linked to a page
Selection

The upper receptor shaft is shared by both Apparatus 1 and Apparatus 2 and is prone to corrosion, so one spare should be kept on the lab safety stock.

Knowing the shaft is common to both apparatuses and corrodes easily justifies stocking a spare to avoid test downtime.

Source
“Upper receptor shaft, 21 in. (total length when assembled)”
Selection

The USP 40-mesh basket is used on Apparatus 1 and is prone to corrosion or bending, so a spare basket should be stocked.

Basket corrosion or bending affects dissolution results, so selecting the recommended basket and keeping a spare is critical.

Source
“Basket, USP, 40-mesh (Top Recommendation)”
Selection

The DLC-coated paddle is preferred over PTFE-coated paddles because its coating withstands typical dissolution tests and cleaning without damage over time.

Coating durability directly affects paddle life and result reproducibility, so this guides the paddle selection.

Source
“The superior Diamond Like Carbon (DLC)-coating can withstand typical Dissolution test and cleaning procedures without getting damaged over time like we see for PTFE-coated paddles”
Selection

TruAlign 1 L vessels are used on both Apparatus 1 and 2 and are easy to break or scratch, so a spare vessel should be kept.

Vessel damage compromises dissolution testing, so selecting the recommended vessel and stocking a spare prevents interruptions.

Source
“TruAlign vessel, 1 L, clear (Top Recommendation)”
Selection

A 250 mL TruAlign conversion kit is required to run small vessels for the Chinese Pharmacopeia on Apparatus 2.

This kit is mandatory when the method requires Chinese Pharmacopeia small-volume testing, so it must be selected upfront.

Source
“Conversion kit to use small vessels for Chinese Pharmacopeia”
Selection

The bent cannula with adjustable gauge is used on both apparatuses and is easy to bend, lose, or corrode, so a spare should be stocked.

Cannula damage or loss stops sampling, so selecting the correct part and keeping a spare maintains operation.

Source
“Bent cannula with adjustable gauge 7.75 in. 708-DS”
Operation

Full Flow UHMWPE 10 µm filters are one-time-use consumables, one per dissolution test, so the 1000/pk convenience pack is recommended.

Knowing the filter is single-use and consumed one per test drives the correct pack size selection and stock planning.

Source
“One-time use consumables, one per Dissolution test, convenience pack”
Selection

Capsule weight wire, 3-prong capsule weights, and JP sinker baskets are Apparatus 2 accessories that are easy to corrode, break, bend, or lose, so spares should be stocked.

These small accessories are easily damaged or lost, so selecting them and keeping safety stock avoids test interruptions.

Source
“Sinker basket, Japanese Pharmacopoeia (JP)”
Operation

Thermal printer paper is a consumable needed to print reports when the 708-DS printer option is used.

Without printer paper the report option cannot produce printed records, so it must be stocked for compliant documentation.

Source
“Consumable to print report with printer option for 708-DS”
Operation

A secondary PES syringe filter is required after the dissolution test to avoid secondary dissolution and prevent contamination of the column and system.

Secondary filtration is a method requirement, so the correct syringe filter must be selected to protect the analytical column and system.

Source
“The dissolution test requires secondary filtration to avoid secondary dissolution and prevent contamination of the column and system”
Operation

Pre-slit PTFE/silicone septa caps prevent the septum from coring when the needle samples.

Septum coring causes particles and injection errors, so selecting pre-slit caps protects sampling reliability.

Source
“Pre-slit septa can prevent the septum from coring when the needle is sampling”
Performance

A-Line screw top vials use the highest purity glass to reduce interference of metal ions from the glass surface with the sample.

Glass purity affects trace metal-sensitive assays, so vial selection must consider this to avoid sample contamination.

Source
“The highest purity glass to reduce the interference of metal ions on glass surface with sample”