Unichiller P007 OLÉ Technical Data

Contents

  1. Overview p. 1
    Product name and cover page for Unichiller P007 OLÉ
  2. Spec p. 2
    Technical data per DIN 12876 with specification table
  3. p. 2 table, 2 rows

Technical data according to DIN 12876

ParameterValue
max. ambient temperature40 °C
from Serial-No.:S458249

Engineering Facts

14 facts · every claim linked to a page
Selection

The unit is rated for an operating temperature range of -20 to 40 °C, so it cannot be used outside this window.

Defines the process temperature envelope for which the chiller can be selected.

Source
“Operating temperature range -20...40 °C”
Performance

Cooling capacity drops from 0.7 kW at 15 °C to 0.2 kW at -20 °C, so low-temperature duty requires derating.

Needed to size the chiller against the actual heat load at the required set point.

Source
“at 15°C 0,7 kW at 0°C 0,55 kW at -10°C 0,4 kW at -20°C 0,2 kW”
Installation

The pump delivers 21 l/min at 0.5 bar but only 6 l/min at 2.0 bar, so system pressure drop must be checked against the pump curve.

Prevents selecting a unit whose flow collapses in a high-pressure-drop loop.

Source
“at 0,5 bar 21 l/min at 1,0 bar 17 l/min at 1,5 bar 11 l/min at 2,0 bar 6 l/min”
Installation

The electrical supply must be 208-240 V single or two-phase at 50/60 Hz with a fuse between 10 A and 16 A.

Determines site power wiring and upstream protection sizing.

Source
“Power supply requirement 208-240V 1~/2~ 50/60Hz max. current 6,5 A min. Fuse 10A max. Fuse 16A”
Installation

Voltage and frequency tolerances must be applied simultaneously, and a -5% voltage with +2% frequency combination is not allowed.

Avoids installing the chiller on a supply that violates the EN60034-1 tolerance combination.

Source
“-5% voltage and +2% frequency -> not allowed!”
Safety

The refrigerant R-449A is classified A1 with GHS H280, and the charge is 0.3 kg corresponding to 0.4 t CO2 equivalent.

Required for refrigerant handling, leak reporting and F-gas compliance assessment.

Source
“R-449A (A1, H280) Global Warming Potential (GWP) 1397 Refrigerant quantity 0,3 kg CO2 equivalent 0,4 t”
Operation

The plastic pump is not resistant to acetone or polyglycols, so these fluids must not be used as the heat transfer medium.

Prevents chemical attack and premature pump failure when choosing the coolant.

Source
“The plastic pump is not resistant against acetone and polyglycols (depending on the manufacturer).”
Operation

For freeze protection, water should be mixed with glysantine or ethylene glycol rather than relying on pure water.

Guides correct heat transfer fluid preparation for sub-zero operation.

Source
“It is recommended that water is mixed with either glysantine or ethylene glycol for freeze protection.”
Installation

The unit has IP20 protection, so it must be installed in a dry indoor location protected from water and dust ingress.

Restricts the installation environment and enclosure requirements.

Source
“Degree of Protection IP20”
Installation

The minimum ambient temperature is 5 °C and the maximum is 40 °C, defining the allowable room conditions.

Ensures the installation room stays within the permitted ambient window.

Source
“min. ambient temperature 5 °C”
Performance

Cooling capacity figures are valid at 20 °C room temperature and may drop if ambient temperature rises.

Requires derating of published capacity when the installation room is warmer than 20 °C.

Source
“Output data valid for: Room temperature 20°C. If the ambient temperature rises, the cooling capacity may drop.”
Installation

Single and two-phase devices are supplied with a power cable and country-specific plug that must be specified at ordering.

Avoids delivery of the wrong plug type and rework at commissioning.

Source
“Single / two-phase devices (100V to 240V) --> with power cable and country-specific plug (please specify when ordering)”
Compliance

The equipment is classified as Class A, Group 1 for electromagnetic disturbance to EN55011.

Class A equipment is intended for industrial environments and may require EMC measures in residential areas.

Source
“Classification (disturbance) to EN55011: Class A, Group 1”
Maintenance

The minimum filling capacity is 3.8 l and the expansion tank is 1.7 l, setting the required loop volume and expansion allowance.

Needed to size the external loop volume and verify expansion capacity.

Source
“min. filling capacity 3,8 l expansion tank 1,7 l”