Unichiller P100-H Technical Datasheet

Contents

  1. Overview p. 1
    Introduces the Unichiller P100-H chiller unit
  2. Spec pp. 1-2
    Performance, temperature, and dimensional data per DIN 12876
  3. p. 2 table, 12 rows
  4. p. 1 table, 32 rows

Technical data according to DIN 12876

ParameterValue
min. filling capacity18 l
Volume of expansion48 l
Overall dimensions WxDxH **740x1160x1165 mm
Net weight299 kg
Power supply (3 Phase)400V 3~ 50Hz
max. current (3 Phase)15 A
Fuse (3 phase)3x16A
Pressure equipment categoryArt. 4.3 PED
Degree of ProtectionIP20
min. ambient temperature5 °C
max. ambient temperature40 °C
from Serial-No.:S625743

** Please respect space requirements. See operating conditions at www.huber-online.com

Technical data according to DIN 12876

ParameterUnichiller P100-H
Order-No.3059.0004.01
Operating temperature range-20...100 °C
temperature set point / display5,7" colour Touchscreen
Internal temperature sensorPt100
Sensor external connectionPt100
Temperature stability at -10°C0,2 K
Interface digitalEthernet, USB (Host u. Device), RS232
Safety classificationIII / FL
Heating power2 kW
Cooling power at ambient temperature +20°C
at 100°C10 kW
at 20°C10 kW
at 0°C7,5 kW
at -10°C4,7 kW
at -20°C2,4 kW
Refrigeration machineair-cooled, CFC- and HCFC-free
Refrigerant (ASHRAE, GHS)R-449A (A1, H280)
Global Warming Potential (GWP)1397
Refrigerant quantity1,1 kg
CO2 equivalent1,5 t
Circulation pump:E2
max. delivery130 l/min
max. delivery pressure5,7 bar
Delivery at 2,4 bar116 l/min
Delivery at 2,5 bar115 l/min
Delivery at 3,0 bar108 l/min
Delivery at 3,5 bar100 l/min
Delivery at 4,0 bar92 l/min
Delivery at 4,5 bar80 l/min
Delivery at 5,0 bar59 l/min
Delivery at 5,5 bar20 l/min
Pump connectionG1 1/4 male

Engineering Facts

14 facts · every claim linked to a page
Selection

The chiller is intended only for externally closed applications, so an open-loop or vented external circuit is not acceptable.

Determines whether the unit can be applied to the customer's process circuit at all.

Source
“For externally closed applications.”
Selection

The P-series pumps are specified for high pressure-drop applications, so they suit restrictive external circuits better than standard pumps.

Guides pump/model choice when the external loop has significant pressure loss.

Source
“Unichiller „P“ Models: Circulating pumps with a high discharge pressure for applications with high pressure drops.”
Performance

Cooling capacity is only valid at 20 °C room temperature and drops as ambient temperature rises, so capacity must be derated for warmer rooms.

Prevents overestimating available cooling at elevated ambient conditions.

Source
“Output data valid for: Room temperature 20°C. If the ambient temperature rises, the cooling capacity may drop.”
Installation

The three-phase unit is supplied with a cable but without a plug, so the installer must provide a suitable 3-phase plug/connection.

Affects electrical installation scope and materials before commissioning.

Source
“Three-phase devices with current consumption less than 63A --> with cable, without plug”
Installation

Voltage and frequency tolerances are linked: ±5 % voltage is allowed only with simultaneous ±2 % frequency, and some combinations are explicitly not allowed.

Needed to verify site power quality before connecting the chiller.

Source
“-5% voltage and +2% frequency -> not allowed!”
Installation

The unit requires 3-phase 400 V 50 Hz supply with max current 15 A and 3x16 A fusing.

Defines the electrical supply and protection rating for installation planning.

Source
“max. current (3 Phase) 15 A”
Installation

The chiller must be installed where ambient temperature stays between 5 °C and 40 °C.

Sets the allowable room/installation environment for reliable operation.

Source
“min. ambient temperature 5 °C”
Safety

The refrigerant R-449A is classified A1 with GHS hazard H280, so refrigerant handling and ventilation precautions apply.

Informs safety assessment and refrigerant handling requirements on site.

Source
“R-449A (A1, H280)”
Compliance

The unit is EMC Class A Group 1, which is industrial-grade emission classification and may not be suitable for residential environments.

Affects EMC compatibility assessment and installation location restrictions.

Source
“Classification (disturbance) to EN55011: Class A, Group 1”
Installation

The unit has IP20 protection, so it must be installed in a dry, protected location and not exposed to water or dust ingress.

Constrains the installation environment and enclosure requirements.

Source
“Degree of Protection IP20”
Selection

The unit contains 1.1 kg of R-449A with GWP 1397, equivalent to 1.5 t CO2, which matters for refrigerant reporting and leak obligations.

Needed for environmental compliance and refrigerant charge documentation.

Source
“CO2 equivalent 1,5 t”
Operation

The controller supports Ethernet, USB host/device and RS232, enabling remote control and data transmission via PC or network.

Determines available integration options for monitoring and remote control.

Source
“Interface digital Ethernet, USB (Host u. Device), RS232”
Maintenance

The expansion tank is atmospheric open and has a digital level indicator, so level monitoring is part of routine operation.

Indicates a maintenance/monitoring point for the heat transfer fluid level.

Source
“With digital level indicator.”
Installation

Space requirements around the unit must be respected per the operating conditions, so clearance planning is mandatory.

Prevents installation in tight spaces that would impair operation or service access.

Source
“** Please respect space requirements. See operating conditions at www.huber-online.com”