Induztr
Engineering Digest Document Viewer Related Models

Agilent IDP Dry Scroll Vacuum Pumps

Contents

  1. Overview pp. 1-2
    Introduces quiet, oil-free, worry-free operation and environmental benefits
  2. Overview p. 3
    Explains clean, quiet operation and lower cost of ownership
  3. Overview p. 4
    Describes innovative hermetic design of the pump
  4. Spec p. 5
    Covers quiet, reliable, oil-free engineering details
  5. Spec p. 6
    Lists smart features available on the pumps
  6. Config p. 7
    Guides selection of the appropriate IDP dry scroll pump
  7. Ordering pp. 8-9
    Provides ordering codes and part numbers for pumps and accessories
  8. Services p. 10
    Highlights service, support, and partnership with Agilent
  9. p. 8 table, 39 rows
  10. p. 9 table, 23 rows
  11. p. 7 table, 6 rows

Ordering information — Agilent IDP Dry Scroll Pumps

DescriptionPart number
IDP-3, 1φ, 220 V, 50/60 HzIDP3A01
IDP-3, 1φ, 115 V, 60 HzIDP3B01
IDP-3, 1φ, 100 V, 50/60 HzIDP3C01
IDP-3, 24 VDCIDP3D01
With inlet isolation valve
IDP-3, 1φ, 220 V, 50/60 HzIDP3A21
IDP-3, 1φ, 115 V, 60 HzIDP3B21
IDP-3, 1φ, 100 V, 50/60 HzIDP3C21
IDP-3, 24 VDCIDP3D21
Service part numbers
IDP-3 tip seal replacement kitIDP3TS
Accessory part numbers
Exhaust silencer kitEXSLRIDP3
Inlet trapSCRINTRPNW16
Vibration isolation kitIDP3VIBISOKIT
IDP-7
DescriptionPart number
IDP-7X3807-64000
IDP-7 with inlet isolation valveX3807-64010
Service part numbers
IDP-7/10 tip seal replacement kitX3807-67000
Accesory part numbers
Exhaust silencer kitX3807-68003
Purge kitX3807-68004
Gas ballast kitX3807-68008
Inlet trapSCRINTRPNW25
Vibration isolation kitSH110VIBISOKIT
IDP-10
DescriptionPart number
IDP-10X3810-64000
IDP-10 with inlet isolation valveX3810-64010
Service part numbers
IDP-7/10 tip seal replacement kitX3807-67000
Accesory part numbers
Exhaust silencer kitX3807-68003
Purge kitX3807-68004
Gas ballast kitX3807-68008
Inlet trapSCRINTRPNW25
Vibration isolation kitSH110VIBISOKIT

Таблица приведена как напечатана: три отдельные секции (IDP-3, IDP-7, IDP-10), каждая со своими заголовками Description / Part number; строки-заголовки секций (Service part numbers, Accessory part numbers) оставлены с пустым Part number.

Ordering information — Agilent IDP Dry Scroll Pumps

DescriptionPart number
IDP-15X3815-64000
IDP-15 with inlet isolation valveX3815-64010
Service part numbers
IDP-15 tip seal replacement kitX3815-67000
Accesory part numbers
Exhaust silencer kitEXSLRSH110
Purge kitX3807-68004
Gas ballast kitX3807-68008
Inlet trapSCRINTRPNW25
IDP-35X3835-64011
IDP-35 with GaugeX3835-64010
IDP-35 with Inlet ValveX3835-64001
IDP-35 with Inlet Valve and GaugeX3835-64000
Accesory part numbers
Inlet HEPA filter, NW40SCRINTRPNW40
HEPA filter, NW25SCRINTRPNW25
IDP-45X3845-64011
IDP-45 with GaugeX3845-64010
IDP-45 with Inlet ValveX3845-64001
IDP-45 with Inlet Valve and GaugeX3845-64000
Accesory part numbers
Inlet HEPA filter, NW40SCRINTRPNW40
HEPA filter, NW25SCRINTRPNW25

How to select your Agilent IDP dry scroll vacuum pump — Agilent IDP Dry Scroll Pumps

IDP modelPumping SpeedBase PressureMotor Rating/operating voltageCommon ApplicationsAdvantages
IDP-360 Hz/24 VDC 60 L/min 3.6 m³/h 50 Hz 50 L/min 3.0 m³/h60 Hz/24 VDC 3.3 x 10-¹ mbar 2.5 x 10-¹ Torr 50 Hz 3.3 x 10-¹ mbar 2.5 x 10-¹ Torr0.16 HP (120 W)/ 100-120; 200-240 VAC- Leak detection - GC/MS - Helium recirculation- Lightest, most compact primary pump - Compact size for integrating the pump into your instrument - 24 V drive
IDP-760 Hz 152 L/min 9.1 m³/h 50 Hz 120 L/min 7.2 m³/h60 Hz 2.6 x 10-² mbar 2.0 x 10-² Torr 50 Hz 4.0 x 10-² mbar 3.0 x 10-² Torr0.38 HP (300 W)/ 100-120; 200-240 VAC- Vacuum ovens - Helium recirculation - Backing high vacuum pump - General laboratory vacuum- More pumping speed in a compact, tabletop pump - Handles water vapor
IDP-1050 Hz or 60 Hz at full rotational speed (factory setting) 170 L/min 10.2 m³/h50 Hz or 60 Hz at full rotational speed (factory setting) 2.0 x 10-² mbar 1.5 x 10-² Torr0.5 HP (350 W)/ 100-127; 200-240 VAC- Microscopy instruments - Surface analysis instruments - Mass Spectrometry - Helium recirculation - Thin film deposition- Universal pumping performance at all input frequencies - Remote speed control or on/off capability
IDP-1560 Hz 256 L/min 15.4 m³/h 50 Hz 214 L/min 12.8 m³/h60 Hz 1.3 x 10-² mbar 1.0 x 10-² Torr 50 Hz 1.3 x 10-² mbar 1.0 x 10-² Torr0.75 HP (560 W)/ 100-115; 220-230 VAC- General laboratory vacuum - Thin film deposition - LED, bulb manufacturing With inlet isolation valve - GC/MS - Beam and particle physics - Backing a turbo pump- Quietest pump available - Lowest vibration at inlet available - Good speed to evacuate a large chamber - Safegaurds your system and high vacuum pump in case of power loss - Isolates the pump inlet during turbulent stop and start
IDP-3560 Hz 583 L/min 35 m³/h60 Hz 1.07 × 10-² mbar 8 × 10-³ Torr1.5 HP (1.1 KW)/ 100-127; 200-240 VAC- Cryogenics - Leak detection - LC/MS - Vacuum ovens - Dry roughing for backing turbo pumps - Beam and particle physics- Hermetically sealed (magnetic torque coupling) - Precise vacuum control - Smart features- visibility and control - Communications/Remote access and control (analog and digital) - Inverter for universal voltage, flexible and easy
IDP-4560 Hz 750 L/min 45 m³/h60 Hz 1.07 × 10-² mbar 8 × 10-³ Torr1.5 HP (1.1 KW)/ 100-127; 200-240 VAC

Значения приведены дословно, как напечатано на странице; для IDP-45 колонки Common Applications и Advantages на странице пусты.

Engineering Facts

12 facts · every claim linked to a page
Maintenance

Tip seal or pumping module replacement is a DIY task needed only about every two to three years and takes roughly half an hour.

Sets realistic maintenance intervals and labor expectations for planning service and spare parts.

Source
“This can be performed approximately every two to three years and requires about half an hour.”
Installation

The pumps use standard IEC power cords that are not hard-wired, simplifying electrical integration.

Affects electrical cabinet design and allows easy cord replacement or regional plug changes.

Source
“Agilent IDP dry scroll pumps also use standard IEC power cords that are not hard-wired to the motor.”
Installation

Small footprint, low weight and minimal power requirements allow use inside cabinet enclosures without special voltage.

Confirms the pump can be enclosed and powered from standard utilities, easing system layout.

Source
“They place litte burden on utilities, require no special voltage, and are suitable for use inside cabinet enclosures.”
Safety

The optional integral isolation valve closes the inlet in about 20 ms on power loss to prevent backstreaming and sudden venting.

Critical for protecting the vacuum system and high-vacuum pump during power interruptions.

Source
“Upon power loss, the solenoid valve vents a small chamber beneath the valve, which closes the inlet valve (approximately 20 milliseconds).”
Operation

After power is restored, the inlet valve reopens in about 10–30 seconds once the pump evacuates.

Defines restart timing and sequencing for automated vacuum control logic.

Source
“Once power is restored, the solenoid closes, the pump evacuates, and the inlet valve opens (approximately 10-30 seconds).”
Operation

IDP-35 and IDP-45 have a tool-free adjustable gas ballast with Hi, Low, or No Flow settings for vapor handling.

Allows operators to optimize performance for water vapor or solvent loads without tools.

Source
“The IDP-35 and IDP-45 models come standard with a simple (no tools), user-adjustable gas ballast knob.”
Performance

The VFD provides consistent pumping performance from 105 VAC to 240 VAC at 50 or 60 Hz.

Enables one pump model to be used globally without voltage-specific variants.

Source
“Get consistent performance worldwide from 105 VAC to 240 VAC (50 Hz or 60 Hz).”
Installation

IDP-35 and IDP-45 offer RS-232, RS-485, or analog interfaces for PC or PLC integration.

Determines available communication options for remote monitoring and control.

Source
“The IDP-35 and IDP-45 dry scroll pumps can be used with RS-232 or RS-485 or with an analog interface.”
Operation

Rotational speed can be reduced after reaching vacuum to lower noise, energy consumption, and wear.

Supports energy-saving and noise-reduction operating strategies.

Source
“Decrease once vacuum pressure is reached to make the system even quieter and reduce energy consumption and wear.”
Selection

IDP-35 and IDP-45 can be fitted with an integrated Pirani gauge covering 1x10-4 to 1000 mbar.

Affects selection when in-built pressure monitoring is required without external gauges.

Source
“fitted with an integrated Pirani gauge head to measure pressures in the range of 1x10-4 to 1000 mbar”
Selection

IDP-35 and IDP-45 are hermetically sealed with magnetic torque coupling, suitable for rare gas and helium recirculation.

Important for applications requiring complete isolation of pumped gases from the environment.

Source
“Hermetically sealed (magnetic torque coupling)”
Selection

IDP-15 is described as the quietest pump available with the lowest vibration at inlet.

Guides selection where acoustic noise and vibration are critical constraints.

Source
“Quietest pump available”