Agilent Technologies 26.48 CFM
Agilent Technologies 26.48 CFM — Vacuum technologies with Motor power 0.119 kW, Pumping speed 3.6 m³/h, Ultimate pressure 3.3 mbar.
The Agilent IDP 26.48 CFM is a dry scroll vacuum pump with a 60 L/min pumping speed and 3.3 mbar base pressure, powered by a 0.16 HP motor. It is configured for 100–120 VAC operation and serves as an oil-free primary pump for analytical instruments and laboratory vacuum systems.
Agilent Technologies Idp Pumps Series — Model Comparison & Selection
| Model | Motor power, kW | Ultimate pressure, mbar | Pumping speed, m³/h | Base pressure, mbar | Supply frequency, Hz | Operating temperature, °C |
|---|---|---|---|---|---|---|
| 26.48 CFM Current | 0.119 | 3.3 | 3.6 | 3.3 | 50 | — |
| 20.60 CFM | 0.119 | 3.3 | 3.6 | 3.3 | 50 | — |
| 6.0 CFM | — | — | — | — | — | — |
| IDP-4 | 0.119 | 2.4 | 3.6 | 3.3 | — | 5 |
| Scroll Pumps for Helium Recirculation & Cryogenic Applications | 0.119 | — | 3.6 | 3.3 | — | — |
Full specifications
| Motor power | 0.16 HP |
| Pumping speed | 60 L/min |
| Ultimate pressure | 3.3 mbar |
| Base Pressure | 3.3 mbar |
| IDP-3, 1φ, 220 V, 50/60 Hz mfr | 3 |
| IDP-3, 1φ, 115 V, 60 Hz mfr | 3 |
| IDP-3, 1φ, 100 V, 50/60 Hz mfr | 3 |
| IDP-3, 24 VDC mfr | 3 |
| IDP-3 tip seal replacement kit mfr | 3 TS |
| Exhaust silencer kit mfr | 110 |
| Inlet trap mfr | 25 |
| Vibration isolation kit mfr | 110 VIBISOKIT |
| Description mfr | Part number number |
| IDP-7 mfr | Vibration isolation kit kit |
| IDP-7 with inlet isolation valve mfr | 3807 |
| IDP-7/10 tip seal replacement kit mfr | 3807 |
| Purge kit mfr | 3807 |
| Gas ballast kit mfr | 3807 |
| IDP-10 mfr | 3810 |
| IDP-10 with inlet isolation valve mfr | 3810 |
| IDP-15 mfr | 3815 |
| IDP-15 with inlet isolation valve mfr | 3815 |
| IDP-15 tip seal replacement kit mfr | 3815 |
| IDP-35 mfr | 3835 |
| IDP-35 with Gauge mfr | 3835 |
| IDP-35 with Inlet Valve mfr | 3835 |
| IDP-35 with Inlet Valve and Gauge mfr | 3835 |
| Inlet HEPA filter, NW40 mfr | 40 |
| HEPA filter, NW25 mfr | 25 |
| IDP-45 mfr | 3845 |
| IDP-45 with Gauge mfr | 3845 |
| IDP-45 with Inlet Valve mfr | 3845 |
| IDP-45 with Inlet Valve and Gauge mfr | 3845 |
| inlet valve closing time mfr | 20 milliseconds |
| inlet valve opening time mfr | 10 seconds |
| Pirani gauge pressure range mfr | -4...1000 mbar |
| IDP-3 mfr | Vibration isolation kit kit |
| IDP-4 mfr | Replacement filter element element |
| inlet valve opening time after power restore mfr | 10 seconds |
| tip seal replacement duration mfr | half an hour hour |
| IDP-4 maintenance duration mfr | 15...30 minutes |
| integrated Pirani gauge pressure range mfr | -4...1000 mbar |
| VPI valve isolation time mfr | 20 ms |
| Supply frequency | 50 Hz |
| Operating voltage mfr | 100 VAC |
Description
Construction and series positioning
The IDP 26.48 CFM is an oil-free dry scroll pump from Agilent's IDP family. Within the series, it shares the 0.16 HP motor, 60 L/min pumping speed, and 3.3 mbar ultimate pressure with the 20.60 CFM sibling, while other siblings (2.1, 5.4, 6.0 CFM) represent smaller-capacity variants. This model is distinguished by its 100–120 VAC operating voltage, making it suitable for North American low-voltage supplies.
Performance behavior
With a base pressure of 3.3 mbar and a pumping speed of 60 L/min, the pump delivers stable performance for rough vacuum applications. No digitized curve points are available, so behavior under varying load cannot be characterized beyond the stated ultimate pressure and speed.
Installation and operation
Document digests indicate the IDP family supports 50 Hz and 60 Hz operating points and model-dependent voltage variants (100–120/200–240 VAC). The 26.48 CFM is specifically the 100–120 VAC variant. The pump is air-cooled and requires adequate ventilation; no additional control or connection details are provided in the available facts.
Integration & Operating Notes
The pump is configured for 100–120 VAC operation. Connecting it to a 200–240 VAC supply will damage the motor. Confirm the facility voltage and use a properly rated circuit; the 0.16 HP motor draws modest current but requires a stable supply.
The pump's base pressure is 3.3 mbar, so it cannot achieve high-vacuum conditions. It is intended as a primary or backing pump for systems requiring rough vacuum, such as backing a turbomolecular pump or for analytical instrument foreline duty.
The IDP series is air-cooled. Install the pump in a well-ventilated area with sufficient clearance for heat dissipation. Do not block the cooling fan or place the pump in an enclosure without ventilation.
Selection & Integration Q&A
Choose the 26.48 CFM when you need 60 L/min pumping speed and 3.3 mbar ultimate pressure with a 100–120 VAC supply. The 20.60 CFM offers identical performance but may have a different voltage configuration; smaller siblings (2.1, 5.4, 6.0 CFM) are for lower flow requirements.
The pump requires a 100–120 VAC supply, matching North American standard mains. Ensure the circuit can handle the 0.16 HP motor's starting and running current. No additional controller or drive is needed; the motor is integrated.
The pump is air-cooled and must be installed with adequate ventilation. Avoid ambient temperatures that could cause overheating. Continuous duty is typical for scroll pumps, but ensure the ultimate pressure is not exceeded for extended periods to prevent wear.
The IDP series is oil-free, eliminating oil changes. Periodic maintenance includes replacing scroll seals and bearings after extended use. Base delivery does not include inlet filters, exhaust silencers, or connection kits; these must be ordered separately as needed.