HiPace 1200 with TC 1200 — instruction manual hipace 1200 i iu with tc 1200

Technical Reference Summary

Covered Models & Document Scope

Pfeiffer Vacuum operating instructions (original, 146 pages) for HiPace 1200 turbopumps prepared for a temperature management system (TMS): variants HiPace 1200 I (standard, upright) and HiPace 1200 IU (upside-down/overhead version), each with DN 200 ISO-K or DN 200 ISO-F high vacuum flange; integrated electronic drive unit TC 1200 (standard or TC 1200 E74 per SEMI E74), electrical connection 110 V AC or 230 V AC.

Section-by-Section Technical Breakdown

pp. 91-92
Product Description

The turbopump is a compact unit with TC 1200 electronic drive unit and integrated power supply pack, prepared for retrofitting a temperature management system (TMS). Cooling is water-based with automatic drive power reduction at excess temperature. Hybrid rotor bearing: wear-free permanent magnetic bearing on the high vacuum side, ceramic-ball bearing lubricated by the integrated operating fluid pump on the fore-vacuum side.

  • Fore-vacuum connection DN 40 ISO-KF; venting connection 1/8" thread; sealing gas (purge) connection
  • Drive power at 100-120 V AC ±10%: 700-930 W; at 200-240 V AC ±10%: 1200 W
  • Scope of delivery includes 50 ml operating fluid with syringe, HAN 3A mains socket, 26-pin remote mating plug, 2× G 1/4" hose nozzles, eye bolts
  • TMS purpose: prevent condensable process residues via controlled housing heating; sealing gas mandatory with TMS
pp. 96-111
Installation

Mechanical installation must precede electrical connection. High vacuum side is connected via ISO-K/ISO-F flanges with detailed counter-flange dimensioning requirements to resist rotor jam torques per ISO 27892; earthquake protection, splinter shields (with pumping speed loss), and vibration compensators are covered. Covers operating fluid filling, fore-vacuum connection, cooling water connection (hose nozzles or pipe fittings), TMS accessories, grounding and electrical safety measures.

  • Only remove original protective covers immediately before flange connection; never start with open vacuum connections
  • Splinter shield / protective screen reduces pumping speed (Tbl. 8)
  • Cooling water requirements and connection versions given in Tbl. 9/10; cooling water inlet max. 6 bar (90 psi)
  • Terminal layout of power supply connector in Tbl. 12; preset accessory connections for TMS in Tbl. 11
  • Keep cables away from hot surfaces > 70 °C; never fill or operate with cleaning agents or residues
pp. 112-118
Operation

Commissioning, operating modes (standalone without operating unit, via E74 connection, via 26-pin remote, via Pfeiffer control unit), switching on, TMS operation after conversion (control commands, Tbl. 14; process description), operation monitoring via LEDs and temperature monitoring, and switching off/venting with factory-set delayed venting (Tbl. 16). Preconfigured TMS delivery settings in Tbl. 13.

  • LED operating mode display on the electronic drive unit (Tbl. 15)
  • Redundant temperature monitoring makes the pump intrinsically safe: drive power is reduced, then switched off at overtemperature
  • Do not fully unscrew the venting screw during venting; venting with impermissibly high rates counts as improper use
pp. 119-126
Maintenance

Maintenance intervals and responsibilities, draining and refilling the operating fluid (filler screw positions depend on mounting orientation, standard vs U version), replacement of the electronic drive unit including speed specification confirmation (nominal speeds in Tbl. 17), and remounting of cooling water pipe fittings. Before any work: switch off, wait for f = 0, unplug mains, secure against restart; never disconnect pump and drive unit while powered or rotating (monitor e.g. [P:398]).

  • Characteristic nominal rotation speeds listed in Tbl. 17 (rating plate: 37,800 1/min, 630 Hz)
  • Electronic drive unit removal/installation procedure with speed specification confirmation step
  • Decontaminate parts exposed to toxic process media before maintenance
pp. 127-129
Decommissioning, Recycling and Disposal

Shutting down for longer periods and recommissioning procedures, plus general disposal information and turbopump-specific disposal (Germany: 'Stillsetzen für längere Zeit').

  • Sections for long-term shutdown, recommissioning, general disposal rules and disposal of turbopumps
pp. 130-137
Malfunctions, Service, Spare Parts and Accessories

Troubleshooting table (Tbl. 18) for turbopump malfunctions, Pfeiffer Vacuum service solutions, spare parts list (Tbl. 19, Fig. 30) and accessories with ordering information (Tbl. 20).

  • Troubleshooting table for turbopumps (Tbl. 18)
  • Spare parts and accessories identified with ordering data (Tbl. 19, Tbl. 20)
pp. 138-144
Technical Data and Dimensions

Pressure unit and gas throughput conversion tables, technical data for HiPace 1200 IU (Tbl. 23), materials in contact with process media (Tbl. 24), and dimension drawings for HiPace 1200 I and IU with DN 200 ISO-F and ISO-K flanges. EC and UK Declarations of Conformity included.

  • Technical data table Tbl. 23 for HiPace 1200 IU; media-contact materials in Tbl. 24
  • Dimension figures for all four variants (DN 200 ISO-F / ISO-K, I / IU)
  • EC and UK Declaration of Conformity included

Key Integration, Operating & Safety Requirements

Specification / Condition Engineering Implication Applies To
Rated rotor speed 37,800 1/min (630 Hz), mass 32.0 kg, protection class I, IP20 (Type 1 per UL 50E) per rating plate data. p.79 ↗ Foundation for lift planning, mounting strength calculations and electrical enclosure selection. HiPace 1200 I / IU all variants
No integrated mains disconnection device; a mains disconnect per SEMI-S2 and a circuit breaker with interrupting rating ≥ 10,000 A must be installed on site. p.83 ↗ Electrical design of the supply side must include these components before commissioning. whole series
Maximum permissible pressure at suction side, venting and sealing gas connections: 1500 hPa absolute. p.84 ↗ Process overpressure above this destroys the pump; interlock gas entry accordingly. whole series
Ambient conditions: 5-40 °C with water cooling, air pressure 750-1060 hPa, altitude ≤ 2000 m, rel. humidity ≤ 80% (T<31 °C) / 50% (T<40 °C), surrounding magnetic field ≤ 6 mT, max irradiated thermal output 22.5 W. p.88 ↗ Site selection and shielding against heat radiation/stray magnetic fields must respect these limits; reduced backing pressure/gas throughput permits higher ambient temperatures. whole series
Max permissible rotor temperature 120 °C and max bakeout temperature at the HV flange 120 °C. p.88 ↗ Bakeout procedures must be limited to 120 °C at the flange. whole series
Drive power: 700-930 W at 100-120 V AC ±10%; 1200 W at 200-240 V AC ±10%. p.92 ↗ Size mains supply, breakers and cabling per the actual supply voltage variant. whole series
Bearing concept: permanent magnetic bearing (wear-free) on the high vacuum side, ceramic-ball bearing lubricated by an integrated operating fluid pump on the fore-vacuum side. p.91 ↗ Operating fluid level and condition are maintenance-relevant for the fore-vacuum side bearing. whole series
Cooling water inlet pressure maximum 6 bar (90 psi); cooling water composition requirements in Tbl. 9 with hose-nozzle (G 1/4") or pipe fitting versions (Tbl. 10). p.79 ↗ Cooling circuit pressure and water quality must be limited/treated accordingly; discharge pressure before connecting hot lines to avoid scalding. whole series
Fore-vacuum connection is DN 40 ISO-KF; venting connection is 1/8" thread; exclusive sealing gas (purge) connection marked by sticker. p.91 ↗ Backing pump and lines must match DN 40 ISO-KF; sealing gas is mandatory when operating with TMS. whole series
Rotor jamming produces destructive torques per ISO 27892; counter flange dimensioning must meet Tbl. 7 requirements; vibration compensator use requires prior consultation with Pfeiffer Vacuum. p.87 ↗ High vacuum flange connection and anchoring must be designed for crash/burst safety; do not casually add vibration compensators. whole series
Splinter shield / protective screen use reduces pumping speed (Tbl. 8). p.98 ↗ Account for effective pumping speed loss when dimensioning the vacuum system with such protection. whole series
Transport: vertical transport with two ex-works eye bolts at max 60° sling angle; horizontal transport with a single M8 × 14 mm eye bolt with washer, screwed to the limit stop opposite the fore-vacuum connection. p.94 ↗ Correct rigging prevents operating-fluid contamination of the pump and sheared eye bolts. whole series
Operating fluid must be drained before transport and filled only after mechanical installation; filler screw positions differ between standard (I) and upside-down (IU) versions. p.93 ↗ Wrong orientation with fluid causes pump contamination up to destruction; follow variant-specific fill/drain figures. HiPace 1200 I vs IU separately
Mechanical installation must always be completed before electrical connection; mating plugs enable automatic run-up on power-on and must only be connected after mechanical installation. p.83 ↗ Prevents cut injuries from unexpected rotor start-up with open HV flange. whole series
Pump is only de-energized when the mains plug is removed and f = 0; during run-down the drive unit still delivers electrical energy — monitor rotation e.g. via [P:398] and never disconnect pump/drive unit while powered or spinning. p.86 ↗ Lockout procedure and run-down wait time are mandatory before any maintenance. whole series
Cooling water systems with heaters require an annual overpressure test; on cooling water leak into a heater, replace the heating jacket completely and install an RCCB on site. p.86 ↗ Prevent lethal electric shock from energized heater surfaces after leaks. installations with heated pump (TMS/heating jacket)
Proper use restricted to vacuum generation with a suitable backing pump, dry and inert gases, closed indoor areas, weatherproof locations; explosive/corrosive media, fluids, dust, ionizing radiation and Ex areas are foreseeable improper use. p.88 ↗ Process compatibility screening is required before deployment; deviations void warranty and conformity. whole series
Temperature monitoring is redundant and intrinsic-safe: on overtemperature the electronic drive unit first reduces drive output, then switches off. p.88 ↗ Thermal overload protection is built-in but backing pressure/gas throughput should still be limited per ambient conditions. whole series
Companion drive-unit documentation: TC 1200 standard = PT 0239 BN; TC 1200 E74 (SEMI E74) = PT 0303 BN; remote interface is a 26-pin D-Sub socket; drive parameters referenced as [P:xxx]. p.78 ↗ Control integration (SEMI E74 or remote D-Sub) must follow the respective drive unit manual. TC 1200 / TC 1200 E74 drive units