Pfeiffer Vacuum HiPace 700 M turbopump with active 5-axis magnetic bearing, driven by the TM 700 electronic drive unit (48 V DC). Covers three variants: DN 160 ISO-K (aluminium flange, PM P04 ...), DN 160 ISO-F (aluminium), DN 160 CF-F (stainless steel). Related drive-unit manuals: TM 700 standard (PT 0329 BN), TM 700 PB Profibus (PT 0354 BN), TM 700 E74 (PT 0355 BN), TM 700 DN DeviceNet (PT 0356 BN), TM 700 EC EtherCAT (PT 0503 BN).

Section-by-Section Technical Breakdown

pp. 10-17
Safety, Limits of Use and Personnel Qualification

Risk assessment per Machinery Directive 2006/42/EC and EN ISO 12100; hazards cover falling objects, electric shock, cuts at open HV flange, rotor-jam torques (ISO 27892), toxic media and overpressure. Defines permissible ambient conditions and improper-use cases. Work restricted to qualified specialists and trained personnel (maintenance levels 1-3).

  • Turbopump and drive unit have no mains disconnection device: an external mains disconnection device per SEMI-S2 and a circuit breaker with ≥ 10,000 A interruption rating are required
  • Power supply pack must provide double isolation between mains input and output per IEC 61010-1, IEC 60950-1 and IEC 62368-1
  • Never exceed 1500 hPa (absolute) inlet pressure on suction side, venting or sealing gas connection
  • Indoor use; air pressure 530-1060 hPa; altitude max. 5000 m; protection degree IP54 / Type 12; pollution degree 2; overvoltage category II; protection class III
  • Ambient temperature: 5-30 °C convection cooling without gas throughput, 5-35 °C air cooling, 5-40 °C water cooling; rel. humidity max 80% at T<31 °C, 50% at T<40 °C
  • Max. surrounding magnetic field 5.0 mT; max. irradiated thermal output 2.4 W; max rotor temperature 110 °C; max bakeout temperature at HV flange 120 °C
  • Proper use: vacuum generation only with suitable backing pump, indoors, dry and inert gases only; improper use includes explosive/corrosive media, condensing vapors, fluids, dust, ionizing radiation, Ex areas
  • Before any service work: switch off, wait for rotor standstill (f = 0), remove mains plug, secure against restart; breaking the warranty seal voids warranty
pp. 18-19
Product Description and Identification

HiPace M series uses active 5-axis magnetic bearings, making the pump maintenance-free and lubrication-free (no hydrocarbon contamination risk on failure). The pump forms a compact unit with the TM 700 electronic drive unit (48 V DC). Cooling options are convection, water, or optional air cooling; a pre-assembled venting valve provides automatic venting after shutdown or power failure.

  • Active 5-axis magnetic bearing, maintenance-free for the entire service life
  • Cooling: convection, water cooling, air cooling (optional); drive power auto-reduced at excessive temperature
  • Rating plate: 49200 1/min (820 Hz), mass 16 kg, IP54 / Type 12, Made in Germany
  • Product designation: HiPace family + size (10-2800) + feature letter; 'M' = active magnetic bearing
  • HV flange variants: DN 160 ISO-K and ISO-F (aluminium), DN 160 CF-F (stainless steel)
  • Scope of delivery: turbopump with electronic drive unit, venting valve, HV and fore-vacuum protective caps, operating instructions
pp. 21-34
Installation (High Vacuum, Fore-Vacuum, Cooling, Venting, Electrical)

Mechanical installation must always precede electrical connection. The counter flange design must meet defined torque, load, flatness and material-strength requirements per ISO 27892 crash/burst safety. Detailed flange-connection procedures (ISO-K, ISO-F, CF-F) with defined tightening torques, plus cooling water, venting, grounding and power supply connections.

  • Counter flange requirements (HiPace 700 M): max burst torque 6500 Nm, max axial load 500 N (50 kg, one-sided load not permitted), flatness ±0.05 mm, flange material tensile strength ≥170 N/mm² at 2.5×d or ≥270 N/mm² at 1.5×d screw engagement depth
  • Splinter shield DN 160 reduces pumping speed: H2 -6%, He -9%, N2 -20%, Ar -23%; protective screen DN 160: H2 -1%, He -2%, N2 -6%, Ar -7%
  • ISO flange fastening: torque wrench (factor ≤ 1.6), WAF 15; tighten cross-wise in 3 steps 5, 15, 25 ± 2 Nm
  • With oil-sealed backing pumps, align fore-vacuum connection downwards vertically with ±25° permissible deviation; all orientations permitted with dry compressing backing pumps
  • Vibration compensator only after consulting Pfeiffer Vacuum; additional securing of pump to HV flange required; on-site torque compensation per ISO 27892
  • Keep lines and cables away from hot surfaces (> 70 °C)
  • Cooling water composition and connection requirements specified in Tbl. 7 and Tbl. 8 (p. 30)
pp. 35-40
Operation, Monitoring and Shutdown/Venting

Operation without an operating unit, via the 26-pole D-Sub 'remote' socket, via E74, via Pfeiffer control unit, or via field bus; drive unit has factory settings on delivery (Tbl. 10). Operating monitoring covers LED mode display, temperature monitoring, safety-bearing wear and balance. Shutdown includes electric brake, emergency power supply option and (delayed) venting with factory settings (Tbl. 12).

  • Operating modes: no operating unit, multi-function 'remote' (26-pole D-Sub), 'E74' connection, Pfeiffer Vacuum control unit, field bus
  • LED behavior and meanings defined in Tbl. 11 (p. 38); redundant temperature monitoring makes the pump intrinsically safe — on overtemperature the drive first reduces output then switches off
  • Temperature, safety bearing wear and balance are monitored during operation
  • Delayed venting factory settings in Tbl. 12 (p. 40); pre-assembled venting valve vents automatically after switch-off or power failure
  • Electric brake and emergency power supply options for shutdown
pp. 41-44
Maintenance and Electronic Drive Unit Replacement

Magnetic bearings make the pump itself maintenance-free; maintenance intervals and responsibilities are tabulated (p. 41). The electronic drive unit TM 700 is replaceable by the customer (remove/install, Fig. 20-21), after which the speed specification must be confirmed using the characteristic nominal rotation speeds of Tbl. 13.

  • Maintenance levels: 1 = trained customer specialist, 2 = customer with technical education / PF service technician, 3 = customer with PF service training / PF service technician
  • Procedure documented for removal and installation of the TM 700 electronic drive unit (p. 42-44)
  • After drive unit replacement, confirm speed specification per Tbl. 13 (characteristic nominal rotation speeds, p. 44)
pp. 45-48
Decommissioning, Recycling/Disposal and Malfunctions

Shut-down and recommissioning procedures for longer standstill periods; general and pump-specific disposal guidance. Malfunctions and troubleshooting are covered in Tbl. 14 (p. 48). Contaminated (toxic process media) parts must be decontaminated before service or disposal.

  • Shutting down for longer periods and recommissioning procedures (p. 45)
  • Troubleshooting table Tbl. 14 (p. 47-48)
  • Decontamination required before maintenance/disposal if toxic media were pumped
pp. 49-54
Spare Parts and Accessories / Ordering Data

Spare parts available for HiPace 700 M are listed in Tbl. 15 with figure reference; accessories (e.g. splinter shields, protective screens, venting valves, power supply packs, flange kits) are listed in Tbl. 16 with ordering information. Only original Pfeiffer accessories/mounting kits may be used.

  • Spare parts overview: Tbl. 15, p. 51 (Fig. 22)
  • Accessory overview and ordering: Tbl. 16, p. 52-54
  • Accessories must be ordered per Tbl. 16; use only Pfeiffer-approved mounting kits
pp. 55-58
Technical Data and Dimensions

Technical data for HiPace 700 M with TM 700 (Tbl. 19, p. 57), materials in contact with process media (Tbl. 20), pressure and gas-throughput unit conversion tables, and dimension drawings for the ISO-K (PM902229), ISO-F (PM902286) and CF-F (PM902287) variants.

  • Technical data table Tbl. 19 (HiPace 700 M | TM 700, p. 57)
  • Materials in contact with media: Tbl. 20 (p. 57); housing aluminum and stainless steel; seals FKM
  • Dimension drawings: ISO-K PM902229, ISO-F PM902286, CF-F PM902287 (p. 57-58)

Key Integration, Operating & Safety Requirements

Specification / Condition Engineering Implication Applies To
Maximum permissible inlet pressure on the suction side, venting and sealing gas connections is 1500 hPa absolute. p.12 ↗ Process-side overpressure must be prevented upstream; exceeding it destroys the pump and ejects parts. whole series
Maximum burst torque at rotor blockage is 6500 Nm (calculated per ISO 27892; not reached in any experimental test). p.22 ↗ Customer-side counter flange and safety connections must be dimensioned to absorb this torque; basis for seismic/earthquake securing design. whole series
Maximum permissible axial load on the high vacuum flange is 500 N (50 kg), one-sided load not permitted. p.22 ↗ Limits weight of chambers, heaters or screens mounted on the pump inlet. HiPace 700 M
Counter flange flatness tolerance is ± 0.05 mm; flange material minimum tensile strength 170 N/mm² at 2.5×d screw engagement depth or 270 N/mm² at 1.5×d. p.22 ↗ Customer-supplied counter flanges must meet these shape/strength tolerances or housing stress, leaks and degraded running behavior result. whole series
ISO flange screw connections are tightened cross-wise in 3 steps at 5, 15, 25 ± 2 Nm with a calibrated torque wrench (factor ≤ 1.6), WAF 15. p.24 ↗ Installers must use this exact torque sequence for ISO-K/ISO-F bracket, hex-head and stud-screw connections. DN 160 ISO-K and ISO-F variants
A DN 160 splinter shield reduces pumping speed by up to 23% (Ar) and a DN 160 protective screen by up to 7% (Ar); for N2: 20% and 6%. p.23 ↗ Effective pumping speed must be derated in system sizing when foreign-particle protection is fitted. DN 160 variants
Rated speed is 49,200 1/min (820 Hz) and pump mass is 16 kg (rating plate data). p.8 ↗ Use for handling planning and for confirming speed specification after drive-unit replacement (Tbl. 13). HiPace 700 M
Ambient temperature limits: 5-30 °C (convection cooling, no gas throughput), 5-35 °C (air cooling), 5-40 °C (water cooling); reduction of backing pressure/gas throughput allows higher ambient temperatures. p.15 ↗ Cooling selection must be matched to the installation environment or drive output is reduced/shut off. whole series
Maximum bakeout temperature at the high vacuum flange is 120 °C; maximum permissible rotor temperature 110 °C; max irradiated thermal output 2.4 W; max surrounding magnetic field 5.0 mT. p.15 ↗ Bakeout procedures and nearby heat/radiation sources must stay within these values or shielding is required. whole series
Protection degree IP54 (Type 12 per UL 50E), protection class III, overvoltage category II, pollution degree 2; installation altitude up to 5000 m with sufficient cooling. p.15 ↗ Defines acceptable indoor installation environments and electrical supply conditions. whole series
Operating voltage of the TM 700 electronic drive unit is 48 V DC; power supply pack must provide double isolation per IEC 61010-1/IEC 60950-1/IEC 62368-1. p.18 ↗ Only compliant or original Pfeiffer power supply packs may be used; non-compliant packs risk fatal electric shock. whole series
Pump and drive unit have no mains switch; a mains disconnection device per SEMI-S2 and a circuit breaker with ≥ 10,000 A interruption rating must be installed externally. p.11 ↗ System integrator must add the disconnection device in the supply line. whole series
Rotor bearing is an active 5-axis magnetic bearing — maintenance-free and lubrication-free for the pump's entire service life (no hydrocarbon contamination risk on failure). p.18 ↗ No oil changes/relubrication scheduled; suitable for hydrocarbon-free UHV applications. HiPace M series
High vacuum flange variants: DN 160 ISO-K and DN 160 ISO-F (aluminium flange) and DN 160 CF-F (stainless steel); fore-vacuum connection DN 25 ISO-KF. p.19 ↗ Determines ordering variant selection and mating flange/hardware procurement. HiPace 700 M variants
With oil-sealed backing pumps, mount with fore-vacuum connection pointing vertically downwards, permissible deviation ± 25°; with dry compressing backing pumps all mounting orientations are allowed. p.23 ↗ Prevents oil backflow into the turbopump; mounting design can be optimized with dry pumps. whole series
Pump is vented automatically after switch-off or power failure via the pre-assembled venting valve; delayed venting has defined factory settings (Tbl. 12); do not fully unscrew the venting screw during manual venting. p.18 ↗ Ensures controlled spin-down; venting-rate limits must be respected (over-fast venting is improper use). whole series
A vibration compensator may shear off the pump in a rotor-jam event; it may only be installed vertically and after consulting Pfeiffer Vacuum, with additional securing of the pump to the HV flange. p.23 ↗ Vibration-sensitive installations need explicit on-site torque compensation measures per ISO 27892. whole series
The electronic drive unit TM 700 is replaceable by the customer; after installation the speed specification must be confirmed against the characteristic nominal rotation speeds in Tbl. 13. p.42 ↗ Reduces downtime; drive-unit swap is a level-1/2 maintenance task with a mandatory verification step. HiPace 700 M with TM 700
Operation interfaces: without operating unit, via 26-pole D-Sub 'remote' socket, via E74, via Pfeiffer control unit, or via field bus (Profibus, DeviceNet, EtherCAT variants of TM 700 with dedicated manuals PT 0354/0356/0503 BN). p.7 ↗ Select the TM 700 variant matching the plant control architecture; parameter settings via [P:xxx] codes. whole series
Proper use is limited to vacuum generation of dry and inert gases indoors with a suitable backing pump; pumping explosive, corrosive media, condensing vapors, fluids, dust, or use in Ex areas / ionizing radiation is improper use and voids warranty/liability. p.15 ↗ Corrosive applications require the separate 'C' corrosive-gas variant, not the standard HiPace 700 M. whole series