Induztr
Engineering Digest Document Viewer Related Models

HiPace 300 M with TM 700 — product leaflet

Technical Reference Summary

Covered Models & Document Scope

Covers the Pfeiffer Vacuum HiPace 300 M turbomolecular vacuum pump with magnetic (electromagnetic) suspension. The document is a 3-page brochure/datasheet; accessories and optional communication interfaces (Profibus, Ethercat, Semi E74) are listed but no ordering codes are given.

Section-by-Section Technical Breakdown

pp. 1
Product Features

Highlights the magnetic-levitation rotor of the HiPace 300 M: maintenance-free operation, wear protection and continuous rotor imbalance compensation. It is described as quiet (low noise/vibration) and hydrocarbon-free, with automatic sensor calibration during operation.

  • Maintenance-free electromagnetic rotor suspension
  • Continuous rotor imbalance compensation
  • Low noise and vibration levels
  • Hydrocarbon-free operation
  • Automatic sensor calibration during operation
pp. 2
Pumping Speed, Compression Ratio and Gas Throughput

Performance data for N2, H2, He and Ar including pumping speeds, compression ratios and gas throughput at final rotational speed and at 0.1 hPa. Also gives maximum forevacuum pressure for N2, run-up time and sound pressure level.

  • Pumping speed: N2 255 l/s, H2 170 l/s, He 215 l/s, Ar 250 l/s
  • Compression ratio: N2 1·10¹¹, H2 5·10⁵, He 1·10⁸, Ar 1·10¹¹
  • Gas throughput at final rotational speed: N2 28 hPa·l/s, Ar 13 hPa·l/s
  • Gas throughput at 0.1 hPa: He 8 hPa·l/s, H2 5 hPa·l/s, N2 10 hPa·l/s
  • Max. forevacuum pressure (N2): 20 hPa
  • Run-up time: 2 min
  • Sound pressure level (EN ISO 2151): 45 dBA
pp. 1, 3
Technical Data, Interfaces and Accessories

Mechanical data (weight, flange connections, mounting orientation) and communication interfaces. Standard interfaces are RS-485 and remote; Profibus, Ethercat and Semi E74 are optional. A list of available accessories, spare parts and options is given.

  • Weight approx. 13.1 kg
  • Gas inlet DN 100 ISO-K/ISO-F/CF-F; outlet DN 16 ISO-KF
  • Mounting orientation: arbitrary
  • Standard interfaces: RS-485, remote
  • Optional interfaces: Profibus, Ethercat, Semi E74
  • Accessories/options: electrical adapter, mains cable, connecting cable, fieldbus systems, power supply kit and display unit, pressure sensor, mounting kit, safety valve, venting accessories, power failure venting unit

Key Integration, Operating & Safety Requirements

Specification / Condition Engineering Implication Applies To
Pumping speed for N2 is 255 l/s (H2 170 l/s, He 215 l/s, Ar 250 l/s) p.2 ↗ Size backing pumps and process budgets against ~255 l/s effective N2 speed at the inlet HiPace 300 M
Compression ratio is 1·10¹¹ for N2 but only 5·10⁵ for H2 p.2 ↗ Ultimate H2 partial pressure strongly depends on forevacuum quality; a good backing pump is needed for hydrogen-sensitive processes HiPace 300 M
Maximum forevacuum pressure for N2 is 20 hPa p.2 ↗ Backing pump and purge design must keep foreline pressure below 20 hPa to avoid rotor overload HiPace 300 M
Gas throughput at final rotational speed is 28 hPa·l/s for N2 and 13 hPa·l/s for Ar p.2 ↗ Limits allowable continuous gas load without the pump slowing down; relevant for process gas dosing HiPace 300 M
Gas throughput at 0.1 hPa high-vacuum pressure is 10 (N2), 8 (He) and 5 (H2) hPa·l/s p.2 ↗ Defines throughput capacity when operating near 0.1 hPa, e.g. during crossover or soft-start processes HiPace 300 M
Run-up time to final speed is 2 minutes p.2 ↗ Interlock process gas/inlets until ~2 min after start; crossover control must account for this delay HiPace 300 M
Sound pressure level is 45 dBA per EN ISO 2151 p.2 ↗ Suitable for lab/quiet environments; no special acoustic enclosure typically required HiPace 300 M
Weight is approx. 13.1 kg p.3 ↗ Mounting flanges and brackets must be rated accordingly; one-person handling feasible HiPace 300 M
Gas inlet is DN 100 ISO-K/ISO-F/CF-F; outlet is DN 16 ISO-KF p.3 ↗ Select matching vacuum fittings and adapters; CF option enables UHV-tight inlet flanging HiPace 300 M
Mounting orientation is arbitrary p.3 ↗ Pump can be installed horizontally or vertically, simplifying integration into existing chambers HiPace 300 M
Rotor uses electromagnetic (magnetic) suspension — maintenance-free with continuous imbalance compensation p.1 ↗ No bearing lubrication or periodic bearing service; oil-free, hydrocarbon-free vacuum suitable for contamination-sensitive processes HiPace 300 M
Standard communication interfaces are RS-485 and remote; Profibus, Ethercat and Semi E74 are optional p.3 ↗ Plan control-system integration: use RS-485 by default, order the corresponding fieldbus option for Profibus/Ethercat/Semi E74 environments HiPace 300 M
Available options include power supply kit with display unit, pressure sensor, safety valve, venting accessories and power failure venting unit p.1 ↗ For venting control on power loss, order the power failure venting unit; safety valve protects against overpressure at the foreline HiPace 300 M
The pump is hydrocarbon-free in operation p.1 ↗ Eliminates oil backstreaming concerns; no trap or foreline oil filter needed for cleanliness-critical applications HiPace 300 M