Induztr
Engineering Digest Document Viewer Related Models

HiPace 2800 IT with TC 1200 — product leaflet

Technical Reference Summary

Covered Models & Document Scope

Pfeiffer Vacuum HiPace 2800 IT and HiPace 3400 IT turbomolecular pumps, IT versions specially designed for ion implantation systems and optimized for light gases (H₂, He). Document is a 3-page datasheet/brochure with technical data, accessories/options list, and marketing highlights; no ordering codes given.

Section-by-Section Technical Breakdown

pp. 1
Product Features

Highlights the pumps' suitability for ion implantation systems with optimized pumping of light gases. Robustness features include an integrated heating system, nickel-coated surfaces for corrosive applications, and hybrid bearing technology for long life.

  • Specially designed for ion implantation systems, optimized for pumping light gases
  • Integrated heating system, suitable for harsh processes, reduced condensation
  • Nickel-coated surfaces for corrosive applications
  • Best-in-class hybrid bearing technology, long life cycle, maximum uptime
pp. 2
Pumping Speed and Compression Data

Detailed performance data for N₂, H₂, He and Ar: pumping speeds, compression ratios, gas throughput at final rotational speed and at 0.1 hPa HV pressure, and maximum forevacuum pressure for N₂. Most values are identical for both models.

  • Pumping speed N₂: 2300 l/s (HiPace 2800 IT) / 3200 l/s (HiPace 3400 IT)
  • Pumping speed H₂: 2600 / 2900 l/s; He: 2900 / 3200 l/s; Ar: 2100 / 2900 l/s
  • Compression ratios (both models): N₂ 1·10⁸, H₂ 4·10³, He 6·10⁴, Ar 1·10⁸
  • Gas throughput at final rotational speed (both): N₂ 18, H₂ 75, He 24, Ar 12 hPa·l/s
  • Gas throughput at 0.1 hPa HV pressure (both): N₂ 50, H₂ 42, He 62 hPa·l/s
  • Max. forevacuum pressure for N₂ (both): 0.8 hPa
pp. 3
General Technical Data

Run-up time, noise level, weight, interfaces, allowed mounting orientations and flange sizes for both models. HiPace 3400 IT uses a larger inlet flange and is heavier.

  • Run-up time: 8.6 min for both models
  • Sound pressure level (EN ISO 2151): 50 dBA for both models
  • Weight: approx. 62 kg (2800 IT) / 65 kg (3400 IT)
  • Standard communication interfaces: RS-485, remote
  • Mounting orientation: 0° (HV flange top) – 90° / 90° – 180° (HV flange bottom)
  • Gas inlet/outlet: DN 250 ISO-F / DN 40 ISO-KF (2800 IT); DN 320 ISO-F / DN 40 ISO-KF (3400 IT)
pp. 1
Accessories, Spare Parts and Options

List of available accessories and options for the HiPace 2800/3400 IT series. No part numbers are given in this document.

  • Electrical adapter
  • Mains cable
  • Connecting cable
  • Display unit
  • Safety and mounting kits
  • Venting accessories
  • Sealing gas accessories

Key Integration, Operating & Safety Requirements

Specification / Condition Engineering Implication Applies To
Pumping speed for N₂ is 2300 l/s (HiPace 2800 IT) and 3200 l/s (HiPace 3400 IT) p.2 ↗ Model selection depends mainly on required N₂ throughput; the 3400 IT gives ~40% more N₂ pumping speed whole series
H₂ pumping speed exceeds N₂ speed: 2600 l/s (2800 IT) and 2900 l/s (3400 IT) p.2 ↗ Confirms optimization for light gases such as hydrogen in ion implantation applications whole series
Compression ratio for H₂ is only 4·10³ vs 1·10⁸ for N₂ and Ar p.2 ↗ Hydrogen requires adequate backing pump performance; foreline H₂ partial pressure will limit ultimate pressure whole series
Maximum forevacuum pressure for N₂ is 0.8 hPa (both models) p.2 ↗ Backing pump must maintain ≤0.8 hPa foreline pressure for safe operation whole series
Gas throughput at final rotational speed for H₂ is 75 hPa·l/s, the highest of all listed gases p.2 ↗ High continuous H₂ throughput capability; size backing line accordingly whole series
Gas throughput at 0.1 hPa HV pressure: He 62, N₂ 50, H₂ 42 hPa·l/s (both models) p.2 ↗ Defines throughput capacity during process operation at moderate HV pressures whole series
Run-up time is 8.6 min for both models p.3 ↗ Full pumping performance available ~9 min after start; relevant for process scheduling whole series
Sound pressure level is 50 dBA per EN ISO 2151 p.3 ↗ Low noise; generally no special acoustic measures needed at typical installation distances whole series
Weight is approx. 62 kg (HiPace 2800 IT) and 65 kg (HiPace 3400 IT) p.3 ↗ Two-person lift or lifting equipment required for mounting whole series
Mounting orientation allowed: 0° (HV flange top) to 90°, and 90° to 180° (HV flange bottom) p.3 ↗ Pump can be installed with inlet up, horizontal, or down; verify support and accessories per orientation whole series
Gas inlet/outlet: DN 250 ISO-F / DN 40 ISO-KF (2800 IT); DN 320 ISO-F / DN 40 ISO-KF (3400 IT) p.3 ↗ 3400 IT needs a DN 320 ISO-F chamber flange and matching adapter; outlet is DN 40 ISO-KF for both HiPace 2800 IT vs HiPace 3400 IT
Standard communication interfaces are RS-485 and remote p.3 ↗ Integrate via RS-485 or hardwired remote control; no other interfaces listed as standard whole series
Integrated heating system reduces condensation, suitable for harsh processes p.1 ↗ Use the heating function in implantation/process environments to protect against condensation whole series
Nickel-coated surfaces for corrosive applications p.1 ↗ Suitable for corrosive process gases without additional external coating whole series (IT variant)
Hybrid bearing technology is used p.1 ↗ Long bearing life cycle and maximum uptime; relevant for maintenance interval planning whole series
Accessories include venting accessories and sealing gas accessories p.1 ↗ Plan for venting and sealing-gas provisions in installation design for corrosive/ionic processes whole series