c190-e292
Technical Reference Summary
Covered Models & Document Scope
Nexera lite inert HPLC system; document also describes system modules LC-40i pump, SCL-40, CBM-40, CBM-40lite, pHM-40, and flow line switching valves
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Flow rate | 0.5 mL/min p.3 ↗ | analytical conditions, gel filtration |
| Column temperature | 25 °C p.3 ↗ | analytical conditions |
| Detection wavelength | 280 nm p.3 ↗ | UV detection |
| Retention time repeatability | 0.08 % RSD p.3 ↗ | n=5 injections |
| Number of degassed solvents | 3 p.8 ↗ | SCL-40 |
| Number of degassed solvents | 5 p.8 ↗ | CBM-40 |
| Analog board channels | Up to 2 channels (option) p.8 ↗ | SCL-40 |
| Analog board channels | Up to 1 channel p.8 ↗ | CBM-40 |
| Injection volume accuracy | ≤ ±1 % p.9 ↗ | µL injection |
| Temperature control range | Room temperature −10 to 100 °C p.9 ↗ | autosampler, standard equipment |
| Temperature control range | Room temperature −10 to 85 °C p.9 ↗ | autosampler without sample cooler |
| Temperature accuracy | ± 0.5 °C p.9 ↗ | standard equipment |
| Temperature accuracy | ± 0.8 °C p.9 ↗ | without sample cooler |
| Temperature precision | ± 0.05 °C p.9 ↗ | standard equipment |
| Temperature precision | ± 0.1 °C p.9 ↗ | without sample cooler |
| Containable column size and number | Up to 250 mm L. column × 6 or 300 mm L. column × 3 mm p.9 ↗ | standard equipment |
| Containable column size and number | Up to 100 mm L. column × 6 or 300 mm L. column × 3 mm p.9 ↗ | without sample cooler |
| Dimensions | W 260 × D 500 × H 415 mm p.9 ↗ | autosampler, standard equipment |
| Weight | 27 kg p.9 ↗ | autosampler, standard equipment |
| Dimensions | W 260 × D 509 × H 415 mm p.9 ↗ | autosampler without sample cooler |
| Weight | 30 kg p.9 ↗ | autosampler without sample cooler |
| Wavelength range | 190 to 700 nm p.9 ↗ | UV detector, deuterium lamp |
| Wavelength range | 190 to 1000 nm p.9 ↗ | UV detector, deuterium and tungsten lamps |
| Wavelength range | 200 to 650 nm p.10 ↗ | fluorescence detector, xenon lamp |
| Cell temperature setting range | 4 to 40 in 1 °C steps °C p.10 ↗ | fluorescence detector, low-pressure mercury lamp |
Operating Limits
- Temperature control range (autosampler, standard equipment): Room temperature −10 °C to 100 °C p.9 ↗
- Temperature control range (autosampler, without sample cooler): Room temperature −10 °C to 85 °C p.9 ↗
- Cell temperature setting range (fluorescence detector): 4 to 40 °C in 1 °C steps p.10 ↗
- Cell temperature control range (fluorescence detector): 10 °C below R.T. to 40 °C p.10 ↗