Shimadzu Nexera Lite Inert
Shimadzu Nexera Lite Inert — Chromatographs with Flow rate 0.5 milliliter/minute.
The Shimadzu Nexera Lite Inert is an inert high-performance liquid chromatograph (HPLC) configured for bio-inert separations, with a maximum operating pressure of 20 MPa. As a member of the Nexera Lite series, it prioritizes inert sample pathways for sensitive analytes while maintaining standard HPLC performance. It serves as the core separation module in analytical workflows requiring metal-sensitive compound compatibility.
Full specifications
| Flow rate | 0.5 mL/min (analytical conditions, gel filtration) |
| Column temperature | 25 °C (analytical conditions) |
| Detection wavelength | 280 nm (UV detection) UV detector, deuterium lamp: 190 to 700 nm · UV detector, deuterium and tungsten lamps: 190 to 1000 nm · fluorescence detector, xenon lamp: 200 to 650 nm |
| Number of degassed solvents | 3 (SCL-40) CBM-40: 5 |
| Retention time repeatability mfr | 0.08 % RSD (n=5 injections) |
| Analog board channels mfr | Up to 2 channels (option) (SCL-40) |
| Analog board channels mfr | Up to 1 channel (CBM-40) |
| Injection volume accuracy mfr | ≤ ±1 % (μL injection) |
| Containable column size and number mfr | Up to 250 mm L. column × 6 or 300 mm L. column × (standard equipment) |
| Containable column size and number mfr | Up to 100 mm L. column × 6 or 300 mm L. column × (without sample cooler) |
| Dimensions mfr | W 260 × D 500 × H 415 mm (autosampler, standard equipment) |
| Dimensions mfr | W 260 × D 509 × H 415 mm (autosampler without sample cooler) |
| Weight | 27 kg (autosampler, standard equipment) autosampler without sample cooler: 30 kg |
| Cell temperature setting range mfr | 4 to 40 in 1 °C steps °C (fluorescence detector, low-pressure mercury lamp) |
Description
Construction and Positioning
- The Nexera Lite Inert is an HPLC system distinguished by its inert flow path, intended for analyses where metal interaction would compromise results. - The system supports a pH Monitor pHM-40 as a detector option, indicating integration with pH monitoring for method development or quality control. ### Performance and Operating Range
- Maximum pressure is 20 MPa, defining the upper limit for column backpressure and flow rate combinations. - No digitized curve points or additional performance data are available; operation should be planned within the stated pressure ceiling. ### Installation and Control
- No PDF digests or manual excerpts were provided, so installation, connection, and control specifics cannot be detailed beyond the detector compatibility noted.
Integration & Operating Notes
Operating above the rated maximum pressure risks damage to the inert flow path components and invalidates results. Ensure method parameters, including flow rate and column selection, keep backpressure below this limit under all expected conditions.
The system lists the pH Monitor pHM-40 as a detector type, so integration with this module is anticipated. Verify compatibility of the monitor's flow cell and connections with the inert flow path to maintain inertness throughout the system.
Selection & Integration Q&A
The pH Monitor pHM-40 is explicitly listed as a detector type. Ensure the detector's flow path materials match the inertness requirements of the system to avoid introducing metal contact.