Induztr
Engineering Digest Document Viewer Related Models

TwisTorr 304 FS Turbomolecular Pump Instruction Manual

Contents

  1. Warning pp. 16-18
    Safety warnings for turbomolecular pump operation and handling
  2. Procedure pp. 19-21
    Storage conditions and procedures for the pump
  3. Procedure pp. 22-24
    Mechanical installation and pump mounting instructions
  4. Procedure pp. 25-27
    Use and operation of the TwisTorr 304 FS
  5. Procedure pp. 28-30
    Disposal instructions for the pump
  6. Overview pp. 31-33
    General product information and introduction
  7. Procedure pp. 34-36
    Preparation steps before installing the pump
  8. Overview pp. 241-243
    Description of the TwisTorr 304 FS pump
  9. Spec pp. 244-279
    Technical specifications, dimensions, and connection details
  10. Config pp. 283-285
    Compatible rack controller and vent configuration
  11. Procedure pp. 286-288
    Installation procedure for the purge valve
  12. Procedure pp. 289-291
    Side mounting installation instructions
  13. Procedure pp. 292-294
    Installation of ConFlat flange connections
  14. Procedure pp. 295-297
    Guidelines for using the pump with corrosive gases
  15. Ordering pp. 298-303
    Ordering information for accessories and spare parts
  16. p. 304
    Customer care contact information
  17. p. 248 table, 18 rows
  18. p. 250 table, 5 rows
  19. p. 233 table, 5 rows
  20. p. 249 table, 25 rows
  21. p. 298 table, 28 rows
  22. p. 234 table, 2 rows
  23. p. 274 table, 2 rows

Tab. 3 Technical Specification

CharacteristicISO 100 / CF 6”ISO 160 / CF 8”
Pumping speed N2250 l/s250 l/s
Pumping speed He255 l/s255 l/s
Pumping speed H2220 l/s220 l/s
Pumping speed Ar250 l/s250 l/s
Max gas throughput at full rotational speed (with recommended forepump) N2 — Air cooling170 sccm170 sccm
Max gas throughput at full rotational speed (with recommended forepump) Ar — Air cooling110 sccm110 sccm
Max gas throughput at full rotational speed (with recommended forepump) N2 — Water cooling170 sccm170 sccm
Max gas throughput at full rotational speed (with recommended forepump) Ar — Water cooling110 sccm110 sccm
Compression ratio N2>1 × 1011>1 × 1011
Compression ratio He>1 × 108>1 × 108
Compression ratio H21.5 × 1061.5 × 106
Compression ratio Ar> 1 × 1011> 1 × 1011
Base pressure with recommended forepump< 1 x 10-10 mbar (< 1 x 10-10 Torr)< 1 x 10-10 mbar (< 1 x 10-10 Torr)
Inlet flangeCFF 6” O.D. ISO 100CFF 8" O.D. ISO 160
Foreline flangeKF16 NW (KF25 – optional)KF16 NW (KF25 – optional)
Rotational speed60000 rpm (1010 Hz driving frequency)60000 rpm (1010 Hz driving frequency)
Start-up time< 3 minutes< 3 minutes
Recommended forepumpmechanical: Agilent DS 102; mechanical: Agilent DS 302; dry pump: Agilent SH 110mechanical: Agilent DS 102; mechanical: Agilent DS 302; dry pump: Agilent SH 110

According to standard DIN 28 428, the base pressure is that measured in a leak-free test dome, 48 hours after the completion of test dome bake-out, with a Turbopump fitted with a ConFlat flange and using the recommended pre-vacuum pump.

Tab. 4 Split Flow (X3500-64010) Technical Specification

N2HeH2Ar
Pumping speed * Main Flange (ISO 100)220 l/s215 l/s215 l/s210 l/s
Pumping speed * Side Port (KF40)5 l/s6.5 l/s7 l/s4 l/s
Compression ratio Total>1 × 10111 x 1071.5 x 105>1 × 1011
Compression ratio Foreline/Side Port>1 x 1062.5 x 1041 x 103>1 x 106
Max gas throughput at full rotational speed (with recommended forepump) Air cooling/Water cooling170 sccm110 sccm

* Pumping speed measured with fluximeter.

Tab. 1

CONTROLLER PART NUMBERPRODUCT NAME
Controller AG Rack baseX3506-64001TwisTorr 304 FS AG Rack
Controller AG Rack with RS232/485X3506-64002TwisTorr 304 FS AG Rack RS232/485
Controller AG Rack with RS232/485 & ProfibusX3506-64003TwisTorr 304 FS AG Rack Profibus
Controller V304 onboard 24VdcX3507-64002TwisTorr 304 FS onboard 24V
Controller V304 onboard 100-240VacX3507-64003TwisTorr 304 FS onboard 110/220V

Technical Specification

ParameterValue
Operating positionAny
Operating ambient temperature+5 °C to +35 °C
Relative humidity of air0 – 90 % (not condensing)
Bakeout temperature80 °C at inlet flange max.
LubricantPermanent lubrication
Cooling requirementsNatural convection (only with no gas load)
Forced air (5- 35 °C ambient temperature)
Water (mandatory if ambient temperature > 35 °C)
Coolant waterMinimum flow: 50 l/h (0.89 GPM)
Temperature: +15 °C to +30 °C
Pressure: 3 to 5 bar (45 to 75 psi)
Noise Pressure level< 50 dB(A) at 1 meter
Pwr supply (mains):
Max input pwr:300 VA
Stand-by pwr:10 W
Max oper. power:150 W with water or air cooling
Installation categoryII
Pollution degree2
Storage temperature-40° C to +70° C
Max altitude3000 m
Weight kg (lbs):
Pump ISO 1005.5 kg (12.3)
Pump CFF 6’’7.5 kg (16.5)
Pump ISO 1605.7 kg (12.6)
Pump CFF 8’’9.7 kg (20.9)

Tab. 5 Accessories and spare parts

DESCRIPTIONPART NUMBER
Mains cable NEMA Plug, 3m long9699958
Mains cable European Plug, 3m long9699957
Serial cable and Navigator Software9699883
Inlet screen, ISO 100X3500-68000
Inlet screen CFF 6’’9699302
Inlet screen, ISO 160X3500-68001
Inlet screen CFF 8’’9699304
Water cooling kit9699337
Plastic water cooling kit9699347
Air cooling kit for On-board ControllerX3500-68010
Air cooling kit for Rack AG ControllerX3500-68011
Fan extension cable9699949
Bracket for On-Board Controller side mountingX3500-68012
Vibration isolator, ISO 1009699344
Vibration isolator, CF 6"9699334
Vibration isolator, ISO 1609699345
Vibration isolator, CF 8"9699335
Vent flange, NW 10 KF / M89699108
Vent valve for AG Rack Controller9699844
Vent valve for on-board Controller9699834
Purge valve 10 SCCM NW16KF – M129699239
Purge valve 10 SCCM ¼ Swagelok – M129699240
Purge valve 20 SCCM NW16KF – M129699241
Purge valve 20 SCCM ¼ Swagelok – M129699242
Purge valve 10 SCCM ¼ Swagelok – ¼ Swagelok9699232
Purge valve 20 SCCM ¼ Swagelok – ¼ Swagelok9699236
TwisTorr 304FS foreline flange KF25X3500-68002
Active GaugesAsk Agilent for details

Tab. 2

FLANGEFIXING DEVICEN.FIXING TORQUE
ISO 100 KM10 clamps422 Nm
ISO 160 KM10 clamps422 Nm

Reduction in pumping speed (%)

ArN2HeH2
X3500-6800020%18%7%5%
X3500-68001

Engineering Facts

14 facts · every claim linked to a page
Installation

The pump must be connected to a suitable Agilent controller and to a primary pump; it cannot be run standalone.

Determines controller selection and requires a backing pump in the system design.

Source
“Die Turbomolekularpumpen TwisTorr 304 FS dürfen nur mit einem der passenden Agilent-Controller verwendet werden und müssen an eine Primärpumpe angeschlossen werden”
Compliance

The pump is installation category II (overvoltage) per EN 61010-1, so the mains supply must meet that category.

Affects electrical supply design and compliance of the installation.

Source
“Der TwisTorr 304 FS gehört zur zweiten Installationsklasse (Überdruck) die von den Normen EN 61010-1 vorgesehen ist.”
Operation

During bakeout the inlet flange must not exceed 120 °C with ConFlat or 80 °C with ISO flanges, and water cooling must always be used.

Sets bakeout limits and mandates water cooling to avoid overheating the pump.

Source
“la temperatura sulla flangia di ingresso non deve essere superiore a 120 °C con flangiatura ConFlat e a 80 °C con flangiatura ISO. Usare sempre il raffreddamento ad acqua durante le operazioni di riscaldamento.”
Safety

Never operate the pump unless the inlet flange is connected to the vacuum chamber or closed with the blank flange.

Prevents rotor damage and hazardous operation during commissioning.

Source
“Non far funzionare mai la pompa se la flangia di ingresso non è collegata alla camera a vuoto o non è chiusa con la flangia di chiusura.”
Operation

Vent pressure at the vent port must be below 2 bar above atmospheric, using dust-free air or inert gas.

Protects bearings and defines venting hardware requirements.

Source
“La pressione di ingresso attraverso l'apposita porta deve essere inferiore a 2 bar (oltre la pressione atmosferica).”
Operation

For gases with particulates or aggressive pollutants, an inert gas purge (N2, He, Ar) must be supplied through the integrated purge/vent port to protect bearings.

Requires purge gas supply and plumbing when pumping dirty or aggressive processes.

Source
“queste pompe sono dotate di una apposita porta (di purge/vent integrato) attraverso la quale è necessario fornire alla pompa un flusso di gas inerte (Azoto, Elio o Argon) per proteggere i cuscinetti della pompa”
Safety

Never use the pump with corrosive gases or vapors that could damage internal materials.

Excludes corrosive processes unless a compatible pump version is selected.

Source
“Non usare mai la pompa in presenza di gas o vapori corrosivi che possano danneggiare i materiali interni alla pompa.”
Installation

The pump can be installed in any position but must be fixed at the inlet flange to a counter-flange able to withstand 1000 Nm torque around its axis.

Defines mounting orientation freedom and the mechanical strength required of the chamber flange.

Source
“Fix the TwisTorr 304 FS in a stable position, mounting the inlet flange of the turbopump to the system counter-flange, with a connection capable of withstanding a torque of 1000 Nm around its axis.”
Installation

ISO-K flanges use 4 M10 high-strength clamps (e.g., Agilent IC63250DCMZ) tightened to 22 Nm.

Specifies clamp count and torque for leak-free, safe mounting.

Source
“ISO 100 K M10 clamps 4 22 Nm”
Installation

The pump cannot be fixed by means of its base; only the inlet flange mounting is allowed.

Prevents an invalid mounting approach that could lead to detachment.

Source
“The TwisTorr 304 FS cannot be fixed by means of its base.”
Operation

The pump must always be cooled before starting; running without cooling can damage internal components.

Requires cooling provision (water or forced air) in the installation design.

Source
“The pump must always be cooled before starting using it. Running the pump without cooling it could damage inside components.”
Operation

A thermistor near the upper bearing stops the pump with Error Code 2 above 60 °C and Error Code 1 below 0 °C.

Explains thermal trip behavior and cooling/ambient requirements.

Source
“If the thermistor reading exceeds 60 °C the pump fails and stops with Error Code = 2. If the thermistor reading is below 0 °C, the pump fails and stops with Error Code = 1”
Maintenance

Before any work, disconnect mains, vent the pump, wait for the rotor to stop and surface temperature below 50 °C.

Defines safe lockout procedure for service and maintenance.

Source
“Alvorens werkzaamheden aan het systeem uit te voeren, de voeding loskoppelen, de pomp met behulp van de hiervoor bestemde klep ontluchten en wachten totdat de rotor volledig stil staat en de oppervlaktetemperatuur van de pomp onder een temperatuur van 50 °C is gezakt.”
Operation

The pump is maintenance-free; any intervention must be performed by authorized personnel.

Sets service strategy: no field maintenance, only authorized repair/exchange.

Source
“De pompen TwisTorr 304 FS zijn onderhoudsvrij. Eventuele werkzaamheden moeten door bevoegd personeel worden uitgevoerd.”