Technical Data Sheet — C-VLR 301 IE3 vacuum pump DE/EN)
Technical Reference Summary
Covered Models & Document Scope
Bombas de vacío C-VLR 301, 401, 501; variantes de 50 Hz y 60 Hz; variantes de tensión VI, SI, Ux, Tx (y Wx listadas sin valores); conexiones Δ/Y
Technical Data
| Parameter | Value | Condición |
|---|---|---|
| Suction capacity | 290 m³/h p.2 ↗ | C-VLR 301, 50 Hz |
| Suction capacity | 350 m³/h p.2 ↗ | C-VLR 301, 60 Hz |
| Suction capacity | 400 m³/h p.2 ↗ | C-VLR 401, 50 Hz |
| Suction capacity | 480 m³/h p.2 ↗ | C-VLR 401, 60 Hz |
| Suction capacity | 500 m³/h p.2 ↗ | C-VLR 501, 50 Hz |
| Suction capacity | 600 m³/h p.2 ↗ | C-VLR 501, 60 Hz |
| Ultimate vacuum at continuous operation | 150 mbar (abs.) p.2 ↗ | C-VLR 301 |
| Ultimate vacuum at continuous operation | 200 mbar (abs.) p.2 ↗ | C-VLR 401 |
| Ultimate vacuum at continuous operation | 200 mbar (abs.) p.2 ↗ | C-VLR 501 |
| Rated voltage | 400 / 690 V ± 10 % p.2 ↗ | 50 Hz |
| Rated voltage | 220 / 380 V ± 10 % p.2 ↗ | 60 Hz |
| Motor rating | 5,5 kW p.2 ↗ | C-VLR 301, 50 Hz |
| Motor rating | 6,5 kW p.2 ↗ | C-VLR 301, 60 Hz |
| Motor rating | 7,5 kW p.2 ↗ | C-VLR 401, 50 Hz |
| Motor rating | 9,0 kW p.2 ↗ | C-VLR 401, 60 Hz |
| Motor rating | 11,0 kW p.2 ↗ | C-VLR 501, 50 Hz |
| Motor rating | 12,6 kW p.2 ↗ | C-VLR 501, 60 Hz |
| Current drawn | 10,1 / 5,85 A p.2 ↗ | C-VLR 301, 50 Hz |
| Current drawn | 13,9 / 8,06 A p.2 ↗ | C-VLR 401, 50 Hz |
| Current drawn | 20,9 / 12,1 A p.2 ↗ | C-VLR 501, 50 Hz |
| Motor efficiency | 89,2 η p.2 ↗ | C-VLR 301, 50 Hz |
| Rotational speed | 2900 rpm p.2 ↗ | C-VLR 301, 50 Hz |
| Rotational speed | 2950 rpm p.2 ↗ | C-VLR 401/501, 50 Hz |
| Average noise level | 74 dB(A) p.2 ↗ | C-VLR 301, 50 Hz, EN ISO 3744 |
| Weight | 285 kg p.2 ↗ | C-VLR 301 |
Operating Limits
- Voltage tolerance: ±10 % p.2 ↗
- Curves/tables tolerance: ±10 % p.2 ↗
- Noise measurement tolerance: ±3 dB(A) p.2 ↗
- Motor thermal class: F p.2 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-5 p.2 ↗ | C-VLR | Product series |
| 6-8 p.2 ↗ | 301 / 401 / 501 | Size |
| field 1 p.2 ↗ | xx | Voltage variant code (VI, SI, Ux, Tx, Wx) |
| field 2 p.2 ↗ | Δ / Y | Motor connection (delta / star) |