Induztr
Résumé technique Visionneuse de documents Modèles associés

Technical Data Sheet — G-BH1 2BH1310 IE3 side channel blower (EN)

Technical Reference Summary

Covered Models & Document Scope

Fiche technique 2BH1 310 : ventilateur à canal latéral avec convertisseur de fréquence intégré (VFD, IP55) pour montage mural ; point de consigne tension/fréquence nominale 345 V / 87 Hz, couplage triangle ; variantes VFD A–K (2FC4xxx-1□□00) et accessoires.

Technical Data

Parameter Value Condition
Rated frequency 87 Hz p.2 ↗ 2BH1310
Rated motor voltage 345 V p.2 ↗ 2BH1310, delta connection
Rated motor current 2,70 A p.2 ↗ 2BH1310
Motor power 0,95 kW p.2 ↗ 2BH1310
Max. differential pressure (vacuum) -130 mbar p.2 ↗ 2BH1310
Max. differential pressure (pressure) 120 mbar p.2 ↗ 2BH1310
Sound level 66 dB(A) p.2 ↗ 2BH1310
Weight 20 kg p.2 ↗ 2BH1310
Protection class IP55 p.2 ↗ integrated frequency converter motor
Rated mains voltage (VFD A) 4,0 V p.2 ↗ 2FC4152-1□□00
Max. motor current (VFD A) 1,5 A p.2 ↗ 2FC4152-1□□00
Typical motor power (VFD A) 3,3 kW p.2 ↗ 2FC4152-1□□00
Rated mains current (VFD A) 10 A p.2 ↗ 2FC4152-1□□00
Fuse (VFD A) 3,9 A p.2 ↗ 2FC4152-1□□00
Weight (VFD A) 2FX16190ER00 kg p.2 ↗ 2FC4152-1□□00, adaptor for wall mounting

Operating Limits

  • Max. suction and ambient temperature for stated total pressure differences: 25 °C p.1 ↗
  • Min. mains voltage for frequency converters: 380 V p.1 ↗
  • Min. pulse frequency for performance curves: 4 kHz p.1 ↗
  • Performance curve tolerance: ± 10 % p.1 ↗
  • Reference air temperature for performance curves: 15 °C p.1 ↗
  • Reference atmospheric pressure for performance curves: 1013 mbar p.1 ↗

Type Code Decoder

Position Token Meaning
1-6 p.2 ↗ 2BH131 Side channel blower type/size designation (2BH1 310)
7-10 p.2 ↗ -1H2 Motor/connection variant field of blower order number
1-6 p.2 ↗ 2FC4xx Frequency converter (VFD) type designation
7-8 p.2 ↗ -1 VFD generation/variant prefix
9-10 p.2 ↗ □□ Placeholder fields in VFD order number (2FC4xxx-1□□00)
11-12 p.2 ↗ 00 Fixed suffix of VFD order number
VFD row letter p.2 ↗ A-K VFD size/power variant (A=2FC4152 … K=2FC4223)

Ordering Data

Ordering Code Part No. Variant / Code S'applique à Note
2BH1310-1H221 p.2 ↗ 2BH1310-1H221 87 Hz, 345 V, delta connection Side channel blower with frequency converter