Hoja de datos 2BH1 430: soplador de canal lateral con convertidor de frecuencia (VFD) integrado, tipo 2BH1 430. Variantes: 2BH1430-1A326 (VFD tipo B, 380 V, 87 Hz) y 2BH1430-1AK26 (VFD tipo A, 400 V, 87 Hz); boca de aspiración en la tapa del soplador número de pedido 2BH1430-7E□□□. VFD integrado 3~ 400 V -15% … 480 V +10%, 50/60 Hz ±6%, IP55, UL 1450.

Technical Data

Parameter Value Condition
Rated motor voltage 380 V p.2 ↗ 2BH1430-1A326, 87 Hz
Rated motor current 5,1 A p.2 ↗ 2BH1430-1A326, 87 Hz
Rated motor power 2,30 kW p.2 ↗ 2BH1430-1A326, 87 Hz
Max. differential pressure, vacuum -120 mbar p.2 ↗ 2BH1430-1A326, 87 Hz
Max. differential pressure, pressure 100 mbar p.2 ↗ 2BH1430-1A326, 87 Hz
Sound pressure level 74 dB(A) p.2 ↗ 2BH1430-1A326, 87 Hz
Weight 29 kg p.2 ↗ 2BH1430-1A326, 87 Hz
Rated motor voltage 400 V p.2 ↗ 2BH1430-1AK26, 87 Hz
Rated motor current 3,45 A p.2 ↗ 2BH1430-1AK26, 87 Hz
Rated motor power 1,60 kW p.2 ↗ 2BH1430-1AK26, 87 Hz
Max. differential pressure, vacuum -10 mbar p.2 ↗ 2BH1430-1AK26, 87 Hz
Max. differential pressure, pressure 10 mbar p.2 ↗ 2BH1430-1AK26, 87 Hz
Sound pressure level 74 dB(A) p.2 ↗ 2BH1430-1AK26, 87 Hz
Weight 22 kg p.2 ↗ 2BH1430-1AK26, 87 Hz
Rated motor voltage 400 V p.2 ↗ 2BH1430-1AK26, 87 Hz, VFD type A
Rated motor current 4,6 A p.2 ↗ 2BH1430-1AK26, 87 Hz, VFD type B
Rated motor power 2,30 kW p.2 ↗ 2BH1430-1AK26, 87 Hz, VFD type B
Max. differential pressure, vacuum -120 mbar p.2 ↗ 2BH1430-1AK26, 87 Hz, VFD type B
Max. differential pressure, pressure 100 mbar p.2 ↗ 2BH1430-1AK26, 87 Hz, VFD type B
Sound pressure level 74 dB(A) p.2 ↗ 2BH1430-1AK26, 87 Hz, VFD type B
Weight 24 kg p.2 ↗ 2BH1430-1AK26, 87 Hz, VFD type B
Rated mains voltage (integrated VFD) 400 -15% … 480 +10% V p.2 ↗ Integrated VFD, 50/60 Hz ±6%
Protection class IP55 p.2 ↗ Integrated VFD and motor
Insulation material class F p.2 ↗ Motor

Operating Limits

  • Max. ambient / suction temperature for stated pressure differences: 25 °C p.1 ↗
  • Performance curve tolerance: ± 10 % p.1 ↗
  • Minimum pulse frequency for frequency converter operation: 4 kHz p.1 ↗
  • Rated voltage/frequency set point: 345 V / 87 Hz p.1 ↗
  • Minimum mains voltage for frequency converters: 380 V p.1 ↗
  • Integrated VFD mains voltage range: 400 V -15% … 480 V +10% p.2 ↗

Type Code Decoder

Position Token Meaning
1-6 p.2 ↗ 2BH1430 Type / size designation (side channel blower 2BH1 430)
7-8 p.2 ↗ -1 Version / design index

Ordering Data

Ordering Code Part No. Variant / Code S'applique à Note
2BH1430-1A326 p.2 ↗ 2BH1430-1A326 B 87 Hz, 380 V, VFD type B Rated current 5,1 A, power 2,30 kW, weight 29 kg
2BH1430-1AK26 p.2 ↗ 2BH1430-1AK26 A 87 Hz, 400 V, VFD type A Rated current 3,45 A, power 1,60 kW, weight 22 kg
2BH1430-1AK26 p.2 ↗ 2BH1430-1AK26 B 87 Hz, 400 V, VFD type B Rated current 4,6 A, power 2,30 kW, weight 24 kg