Technical Data Sheet — G-BH1 2BH1430 IE3 side channel blower (EN)
Technical Reference Summary
Covered Models & Document Scope
Hoja de datos 2BH1 430: soplador de canal lateral con convertidor de frecuencia (VFD) integrado, tipo 2BH1 430. Variantes: 2BH1430-1A326 (VFD tipo B, 380 V, 87 Hz) y 2BH1430-1AK26 (VFD tipo A, 400 V, 87 Hz); boca de aspiración en la tapa del soplador número de pedido 2BH1430-7E□□□. VFD integrado 3~ 400 V -15% … 480 V +10%, 50/60 Hz ±6%, IP55, UL 1450.
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Rated motor voltage | 380 V p.2 ↗ | 2BH1430-1A326, 87 Hz |
| Rated motor current | 5,1 A p.2 ↗ | 2BH1430-1A326, 87 Hz |
| Rated motor power | 2,30 kW p.2 ↗ | 2BH1430-1A326, 87 Hz |
| Max. differential pressure, vacuum | -120 mbar p.2 ↗ | 2BH1430-1A326, 87 Hz |
| Max. differential pressure, pressure | 100 mbar p.2 ↗ | 2BH1430-1A326, 87 Hz |
| Sound pressure level | 74 dB(A) p.2 ↗ | 2BH1430-1A326, 87 Hz |
| Weight | 29 kg p.2 ↗ | 2BH1430-1A326, 87 Hz |
| Rated motor voltage | 400 V p.2 ↗ | 2BH1430-1AK26, 87 Hz |
| Rated motor current | 3,45 A p.2 ↗ | 2BH1430-1AK26, 87 Hz |
| Rated motor power | 1,60 kW p.2 ↗ | 2BH1430-1AK26, 87 Hz |
| Max. differential pressure, vacuum | -10 mbar p.2 ↗ | 2BH1430-1AK26, 87 Hz |
| Max. differential pressure, pressure | 10 mbar p.2 ↗ | 2BH1430-1AK26, 87 Hz |
| Sound pressure level | 74 dB(A) p.2 ↗ | 2BH1430-1AK26, 87 Hz |
| Weight | 22 kg p.2 ↗ | 2BH1430-1AK26, 87 Hz |
| Rated motor voltage | 400 V p.2 ↗ | 2BH1430-1AK26, 87 Hz, VFD type A |
| Rated motor current | 4,6 A p.2 ↗ | 2BH1430-1AK26, 87 Hz, VFD type B |
| Rated motor power | 2,30 kW p.2 ↗ | 2BH1430-1AK26, 87 Hz, VFD type B |
| Max. differential pressure, vacuum | -120 mbar p.2 ↗ | 2BH1430-1AK26, 87 Hz, VFD type B |
| Max. differential pressure, pressure | 100 mbar p.2 ↗ | 2BH1430-1AK26, 87 Hz, VFD type B |
| Sound pressure level | 74 dB(A) p.2 ↗ | 2BH1430-1AK26, 87 Hz, VFD type B |
| Weight | 24 kg p.2 ↗ | 2BH1430-1AK26, 87 Hz, VFD type B |
| Rated mains voltage (integrated VFD) | 400 -15% … 480 +10% V p.2 ↗ | Integrated VFD, 50/60 Hz ±6% |
| Protection class | IP55 p.2 ↗ | Integrated VFD and motor |
| Insulation material class | F p.2 ↗ | Motor |
Operating Limits
- Max. ambient / suction temperature for stated pressure differences: 25 °C p.1 ↗
- Performance curve tolerance: ± 10 % p.1 ↗
- Minimum pulse frequency for frequency converter operation: 4 kHz p.1 ↗
- Rated voltage/frequency set point: 345 V / 87 Hz p.1 ↗
- Minimum mains voltage for frequency converters: 380 V p.1 ↗
- Integrated VFD mains voltage range: 400 V -15% … 480 V +10% p.2 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-6 p.2 ↗ | 2BH1430 | Type / size designation (side channel blower 2BH1 430) |
| 7-8 p.2 ↗ | -1 | Version / design index |
Ordering Data
| Ordering Code | Part No. | Variant / Code | S'applique à | Note |
|---|---|---|---|---|
| 2BH1430-1A326 p.2 ↗ | 2BH1430-1A326 | B | 87 Hz, 380 V, VFD type B | Rated current 5,1 A, power 2,30 kW, weight 29 kg |
| 2BH1430-1AK26 p.2 ↗ | 2BH1430-1AK26 | A | 87 Hz, 400 V, VFD type A | Rated current 3,45 A, power 1,60 kW, weight 22 kg |
| 2BH1430-1AK26 p.2 ↗ | 2BH1430-1AK26 | B | 87 Hz, 400 V, VFD type B | Rated current 4,6 A, power 2,30 kW, weight 24 kg |
Modèles liés
Elmo Rietschle 2BH1009
Elmo Rietschle 2BH1014
Elmo Rietschle 2BH1015
Elmo Rietschle 2BH1023
Elmo Rietschle 2BH1035
Elmo Rietschle 2BH1100
Elmo Rietschle 2BH1200
Elmo Rietschle 2BH1300
Elmo Rietschle 2BH1310
Elmo Rietschle 2BH1330
Elmo Rietschle 2BH1400
Elmo Rietschle 2BH1410
Elmo Rietschle 2BH1430
Elmo Rietschle 2BH1490
Elmo Rietschle 2BH1500
Elmo Rietschle 2BH1510
Elmo Rietschle 2BH1530
Elmo Rietschle 2BH1590
Elmo Rietschle 2BH1600
Elmo Rietschle 2BH1610
Elmo Rietschle 2BH1630
Elmo Rietschle 2BH1640
Elmo Rietschle 2BH1690
Elmo Rietschle 2BH1800
Elmo Rietschle 2BH1810
Elmo Rietschle 2BH1830
Elmo Rietschle 2BH1900
Elmo Rietschle 2BH1910
Elmo Rietschle 2BH1930
Elmo Rietschle 2BH1940
Elmo Rietschle 2BH1943