Technical Data Sheet — G-BH1 2BH1600 ATEX vacuum pump (EN)
Technical Reference Summary
Covered Models & Document Scope
Hoja de datos 2BH1 600: soplador de canal lateral en configuración ATEX (G-BH1 N), tamaños 2BH1600, categorías ATEX 3GD, 3/2D y 3/2G, máquinas de tensión fija para 50 Hz y 60 Hz; código de pedido 2BH1…-1.□.□-Z con Z=M34/M74/M71 y sustituciones en el campo de tensión/ATEX.
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Rated voltage | 400 / 690 V p.2 ↗ | 2BH1600, 50 Hz, Δ/Y |
| Rated voltage | 460 V p.2 ↗ | 2BH1600, 60 Hz, Δ |
| Current | 4.20 / 2.40 A p.2 ↗ | 2BH1600, 50 Hz, Δ/Y |
| Current | 4.20 A p.2 ↗ | 2BH1600, 60 Hz, Δ |
| Power | 3.0 hp p.2 ↗ | 2BH1600, 50 Hz |
| Power | 3.4 hp p.2 ↗ | 2BH1600, 60 Hz |
| Max. vacuum | -68.25 inch H2O p.2 ↗ | 2BH1600, 50 Hz |
| Max. vacuum | -56.2 inch H2O p.2 ↗ | 2BH1600, 60 Hz |
| Max. differential pressure | 60.2 inch H2O p.2 ↗ | 2BH1600, 50 Hz |
| Max. differential pressure | 52.1 inch H2O p.2 ↗ | 2BH1600, 60 Hz |
| Sound pressure level | 69 dB(A) p.2 ↗ | 2BH1600, 50 Hz |
| Sound pressure level | 69 dB(A) p.2 ↗ | 2BH1600, 60 Hz |
| Weight | 168 lbs p.2 ↗ | 2BH1600, 50 Hz |
| Weight | 187 lbs p.2 ↗ | 2BH1600, 60 Hz |
| Degree of protection | IP55 p.2 ↗ | 2BH1600 |
| ATEX category | 3/2G p.2 ↗ | 2BH1600, 50 Hz |
| ATEX category | 3/2D, 3GD p.2 ↗ | 2BH1600, 50 Hz |
| ATEX category | 3/2G p.2 ↗ | 2BH1600, 60 Hz |
| ATEX category | 3/2D, 3GD p.2 ↗ | 2BH1600, 60 Hz |
Operating Limits
- Performance curve reference air temperature: 59 °F p.1 ↗
- Performance curve reference atmospheric pressure: 29.92 inch Hg p.1 ↗
- Performance curve tolerance: ± 10 % p.1 ↗
- Degree of protection: IP55 p.2 ↗
- ATEX category 3GD marking: II 3G IIB T3 Gc and II 3D T125°C Dc p.2 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-4 p.2 ↗ | 2BH1 | Series G-BH1 side channel blower |
| 5-7 p.2 ↗ | 600 | Size 600 |
| field 1 p.2 ↗ | 1 | Version field (fixed as 1 in printed code) |
| field 2 p.2 ↗ | D | Voltage/connection variant: D = 230 Δ/400 Y or 400 Δ/690 Y or 500 Δ (50 Hz), 460 Δ or 575 Δ (60 Hz) |
| field 2 p.2 ↗ | G | Voltage/connection variant: G = 460 Y or 460 Δ or 575 Δ (60 Hz only) |
| field 3 p.2 ↗ | 1 | Voltage code: 230 Δ/400 Y (50 Hz) or 460 Y (60 Hz) |
| field 3 p.2 ↗ | 6 | Voltage code: 400 Δ/690 Y (50 Hz) or 460 Δ (60 Hz) |
| field 3 p.2 ↗ | 5 | Voltage code: 500 Δ (50 Hz) or 575 Δ (60 Hz) |
Modèles liés
Elmo Rietschle 2BH1009
Elmo Rietschle 2BH1014
Elmo Rietschle 2BH1015
Elmo Rietschle 2BH1023
Elmo Rietschle 2BH1035
Elmo Rietschle 2BH1100
Elmo Rietschle 2BH1200
Elmo Rietschle 2BH1300
Elmo Rietschle 2BH1310
Elmo Rietschle 2BH1330
Elmo Rietschle 2BH1400
Elmo Rietschle 2BH1410
Elmo Rietschle 2BH1430
Elmo Rietschle 2BH1490
Elmo Rietschle 2BH1500
Elmo Rietschle 2BH1510
Elmo Rietschle 2BH1530
Elmo Rietschle 2BH1590
Elmo Rietschle 2BH1600
Elmo Rietschle 2BH1610
Elmo Rietschle 2BH1630
Elmo Rietschle 2BH1640
Elmo Rietschle 2BH1690
Elmo Rietschle 2BH1800
Elmo Rietschle 2BH1810
Elmo Rietschle 2BH1830
Elmo Rietschle 2BH1900
Elmo Rietschle 2BH1910
Elmo Rietschle 2BH1930
Elmo Rietschle 2BH1940
Elmo Rietschle 2BH1943