Induztr
Résumé technique Visionneuse de documents Modèles associés

Technical Data Sheet — G-BH1 2BH1800 IE3 side channel blower (EN)

Technical Reference Summary

Covered Models & Document Scope

Fiche technique 2BH1 800 : ventilateur à canal latéral avec convertisseur de fréquence intégré (VFD). Couvre les types de VFD G (2BH1800-1A316, 2BH1800-1A326) et F (2BH1800-1AK06, 2BH1800-1AK16, 2BH1800-1AK26), VFD intégré 3~ 400 V, 50/60 Hz, IP55.

Technical Data

Parameter Value Condition
Rated motor voltage 370 V p.2 ↗ 2BH1800-1A316, 85 Hz
Rated motor current 21,5 A p.2 ↗ 2BH1800-1A316, 85 Hz
Rated motor power 10,2 kW p.2 ↗ 2BH1800-1A316, 85 Hz
Max. differential pressure vacuum -220 mbar p.2 ↗ 2BH1800-1A316, 85 Hz
Max. differential pressure pressure 180 mbar p.2 ↗ 2BH1800-1A316, 85 Hz
Sound pressure level 79/80 dB(A) p.2 ↗ 2BH1800-1A316, 85 Hz
Weight 119 kg p.2 ↗ 2BH1800-1A316
Rated motor voltage 380 V p.2 ↗ 2BH1800-1A326, 85 Hz
Rated motor current 27,4 A p.2 ↗ 2BH1800-1A326, 85 Hz
Rated motor power 14,0 kW p.2 ↗ 2BH1800-1A326, 85 Hz
Max. differential pressure vacuum -380 mbar p.2 ↗ 2BH1800-1A326, 85 Hz
Max. differential pressure pressure 320 mbar p.2 ↗ 2BH1800-1A326, 85 Hz
Sound pressure level 79/80 dB(A) p.2 ↗ 2BH1800-1A326, 85 Hz
Weight 158 kg p.2 ↗ 2BH1800-1A326
Rated motor voltage 400 V p.2 ↗ 2BH1800-1AK06, 85 Hz
Rated motor current 14,4 A p.2 ↗ 2BH1800-1AK06, 85 Hz
Rated motor power 7,5 kW p.2 ↗ 2BH1800-1AK06, 85 Hz
Max. differential pressure vacuum -90 mbar p.2 ↗ 2BH1800-1AK06, 85 Hz
Max. differential pressure pressure 80 mbar p.2 ↗ 2BH1800-1AK06, 85 Hz
Sound pressure level 79/80 dB(A) p.2 ↗ 2BH1800-1AK06, 85 Hz
Weight 113 kg p.2 ↗ 2BH1800-1AK06
Rated motor voltage 400 V p.2 ↗ 2BH1800-1AK16, 85 Hz
Rated motor current 20,0 A p.2 ↗ 2BH1800-1AK16, 85 Hz
Rated motor power 10,2 kW p.2 ↗ 2BH1800-1AK16, 85 Hz
Max. differential pressure vacuum -220 mbar p.2 ↗ 2BH1800-1AK16, 85 Hz

Operating Limits

  • Max. ambient/suction temperature for stated pressure differences: 25 °C p.1 ↗
  • Min. mains voltage for frequency converter: 380 V p.1 ↗
  • Rated voltage/frequency set point: 345 V / 87 Hz p.1 ↗
  • Protection class: IP55 p.2 ↗
  • Insulation material class: F p.2 ↗
  • VFD mains voltage range: 3~ 400 V -15% … 480 V +10% p.2 ↗

Type Code Decoder

Position Token Meaning
1-6 p.2 ↗ 2BH1800 Type designation: side channel blower 2BH1, size 800
7-8 p.2 ↗ 1A Motor variant / winding code
9-10 p.2 ↗ 31 / 32 / K0 / K1 / K2 Variant code: 31/32 = VFD type G; K0/K1/K2 = VFD type F

Ordering Data

Ordering Code Part No. Variant / Code S'applique à Note
2BH1800-1A316 p.2 ↗ 2BH1800-1A316 G VFD type G, 85 Hz, 370 V 10.2 kW, -220/180 mbar
2BH1800-1A326 p.2 ↗ 2BH1800-1A326 G VFD type G, 85 Hz, 380 V 14.0 kW, -380/320 mbar
2BH1800-1AK06 p.2 ↗ 2BH1800-1AK06 F VFD type F, 85 Hz, 400 V 7.5 kW, -90/80 mbar
2BH1800-1AK16 p.2 ↗ 2BH1800-1AK16 F VFD type F, 85 Hz, 400 V 10.2 kW, -220/180 mbar
2BH1800-1AK26 p.2 ↗ 2BH1800-1AK26 F VFD type F, 85 Hz, 400 V 14.0 kW, -380/320 mbar