Technical Data Sheet — 2BH1800 IE3 vacuum pump (EN)
Technical Reference Summary
Covered Models & Document Scope
Ficha técnica 2BH1 800-1: soplador de canal lateral con motores IE3, 3~ 50/60 Hz, IP55, clase de aislamiento F, UL 1450 y CAN/CSA C22.2 No. 68-09 (certificado E225239). Abarca los tamaños de rendimiento 1, 2, 3 y las variantes de tensión/frecuencia (190-210 V Δ, 220-240 V Δ / 380-420 V Y, 380-420 V Δ / 660-725 V Y, 475-525 V Y, 550-600 V Y, 440-480 V Δ, 460 V Δ, 200 V Y, 230 V Y / 460 V Y).
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Rated voltage | 190-210 V p.2 ↗ | 2BH1800-1AK01, size 1, 50 Hz, Δ |
| Rated current | 17,1 A p.2 ↗ | 2BH1800-1AK01, size 1, 50 Hz, Δ |
| Motor power | 4,6 kW p.2 ↗ | 2BH1800-1AK01, size 1, 50 Hz |
| Max. pressure | 210 mbar p.2 ↗ | 2BH1800-1AK01, size 1, 50 Hz |
| Max. vacuum | -220 mbar p.2 ↗ | 2BH1800-1AK01, size 1, 50 Hz |
| Sound pressure level | 71 dB(A) p.2 ↗ | 2BH1800-1AK01, size 1, 50 Hz |
| Efficiency class | IE3 p.2 ↗ | 2BH1800-1AK01, size 1, 50 Hz |
| Weight | 113 kg p.2 ↗ | 2BH1800-1AK01, size 1, 50 Hz |
| Rated voltage | 190-210 / 380-420 V p.2 ↗ | 2BH1800-1AK01, size 1, 60 Hz, Δ/Y |
| Rated current | 19,6 / 9,8 A p.2 ↗ | 2BH1800-1AK01, size 1, 60 Hz, Δ/Y |
| Motor power | 5,3 kW p.2 ↗ | 2BH1800-1AK01, size 1, 60 Hz |
| Max. pressure | 180 mbar p.2 ↗ | 2BH1800-1AK01, size 1, 60 Hz |
| Max. vacuum | -190 mbar p.2 ↗ | 2BH1800-1AK01, size 1, 60 Hz |
| Sound pressure level | 73 dB(A) p.2 ↗ | 2BH1800-1AK01, size 1, 60 Hz |
| Rated voltage | 190-210 V p.2 ↗ | 2BH1800-1AK11, size 2, 50 Hz, Δ |
| Rated current | 23,5 A p.2 ↗ | 2BH1800-1AK11, size 2, 50 Hz, Δ |
| Motor power | 6,3 kW p.2 ↗ | 2BH1800-1AK11, size 2, 50 Hz |
| Max. pressure | 320 mbar p.2 ↗ | 2BH1800-1AK11, size 2, 50 Hz |
| Max. vacuum | -320 mbar p.2 ↗ | 2BH1800-1AK11, size 2, 50 Hz |
| Sound pressure level | 72 dB(A) p.2 ↗ | 2BH1800-1AK11, size 2, 50 Hz |
| Weight | 124 kg p.2 ↗ | 2BH1800-1AK11, size 2, 50 Hz |
| Rated voltage | 190-210 V p.2 ↗ | 2BH1800-1AK21, size 3, 50 Hz, Δ |
| Rated current | 30,8 A p.2 ↗ | 2BH1800-1AK21, size 3, 50 Hz, Δ |
| Motor power | 8,6 kW p.2 ↗ | 2BH1800-1AK21, size 3, 50 Hz |
| Max. pressure | 450 mbar p.2 ↗ | 2BH1800-1AK21, size 3, 50 Hz |
Operating Limits
- Max. ambient / suction temperature for stated total pressure differences: 25 °C p.1 ↗
- Performance curve tolerance: ± 10 % p.1 ↗
- Protection class: IP55 p.2 ↗
- Insulation class: F p.2 ↗
- Max. pressure (size 3, 50 Hz): 450 mbar p.2 ↗
- Max. vacuum (size 3, 50 Hz): -320 mbar p.2 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-4 p.2 ↗ | 2BH1 | Series: side channel blower |
| 5-8 p.2 ↗ | 800-1 | Size / model designation |
| field 1 p.2 ↗ | 1 | Performance size 1, 2 or 3 |
| field 2 p.2 ↗ | A | Voltage/frequency variant group (A = 50/60 Hz dual voltage, Q = 60 Hz / special voltage) |
| field 3 p.2 ↗ | K | Voltage code: K = 190-210 V Δ / 380-420 V Y (50 Hz), 190-210 V Δ / 380-420 V Y (60 Hz); Q = 475-525 V Y (50 Hz), 550-600 V Y (60 Hz) |
| field 4 p.2 ↗ | 0 | Fixed digit |
| field 5 p.2 ↗ | 1 | Fixed digit |
| field 6 p.2 ↗ | □ | Voltage connection / frequency option: 6 = 220-240 V Δ / 380-420 V Y (50 Hz), 440-480 V Y (60 Hz); 7 = 380-420 V Δ / 660-725 V Y (50 Hz), 440-480 V Δ (60 Hz) |
Ordering Data
| Ordering Code | Part No. | Variant / Code | S'applique à | Note |
|---|---|---|---|---|
| 2BH1800-1AK01 p.2 ↗ | 2BH1800-1AK01 | size 1, 50/60 Hz, 190-210 V Δ / 380-420 V Y | IE3, 4,6 kW (50 Hz) / 5,3 kW (60 Hz), 113 kg | |
| 2BH1800-1AK11 p.2 ↗ | 2BH1800-1AK11 | size 2, 50/60 Hz, 190-210 V Δ / 380-420 V Y | IE3, 6,3 kW (50 Hz) / 7,3 kW (60 Hz), 124 kg | |
| 2BH1800-1AK21 p.2 ↗ | 2BH1800-1AK21 | size 3, 50/60 Hz, 190-210 V Δ / 380-420 V Y | IE3, 8,6 kW (50 Hz) / 9,9 kW (60 Hz), 135 kg | |
| 2BH1800-1AK06 p.2 ↗ | 2BH1800-1AK06 | size 1, 50/60 Hz, 220-240 V Δ / 380-420 V Y | IE3, 4,6 kW (50 Hz) / 5,3 kW (60 Hz), 113 kg | |
| 2BH1800-1AK16 p.2 ↗ | 2BH1800-1AK16 | size 2, 50/60 Hz, 220-240 V Δ / 380-420 V Y | IE3, 6,3 kW (50 Hz) / 7,3 kW (60 Hz), 124 kg | |
| 2BH1800-1AK26 p.2 ↗ | 2BH1800-1AK26 | size 3, 50/60 Hz, 220-240 V Δ / 380-420 V Y | IE3, 8,6 kW (50 Hz) / 9,9 kW (60 Hz), 135 kg | |
| 2BH1800-1AQ03 p.2 ↗ | 2BH1800-1AQ03 | size 1, 50/60 Hz, 475-525 V Y / 550-600 V Y | IE3, 4,6 kW (50 Hz) / 5,3 kW (60 Hz) | |
| 2BH1800-1AQ13 p.2 ↗ | 2BH1800-1AQ13 | size 2, 50/60 Hz, 475-525 V Y / 550-600 V Y | IE3, 6,3 kW (50 Hz) / 7,3 kW (60 Hz) | |
| 2BH1800-1AQ23 p.2 ↗ | 2BH1800-1AQ23 | size 3, 50/60 Hz, 475-525 V Y / 550-600 V Y | IE3, 8,6 kW (50 Hz) / 9,9 kW (60 Hz) | |
| 2BH1800-1AQ07 p.2 ↗ | 2BH1800-1AQ07 | size 1, 50/60 Hz, 380-420 V Δ / 660-725 V Y | IE3, 4,6 kW (50 Hz) / 5,3 kW (60 Hz), 110 kg |
Modèles liés
Elmo Rietschle 2BH1009
Elmo Rietschle 2BH1014
Elmo Rietschle 2BH1015
Elmo Rietschle 2BH1023
Elmo Rietschle 2BH1035
Elmo Rietschle 2BH1100
Elmo Rietschle 2BH1200
Elmo Rietschle 2BH1300
Elmo Rietschle 2BH1310
Elmo Rietschle 2BH1330
Elmo Rietschle 2BH1400
Elmo Rietschle 2BH1410
Elmo Rietschle 2BH1430
Elmo Rietschle 2BH1490
Elmo Rietschle 2BH1500
Elmo Rietschle 2BH1510
Elmo Rietschle 2BH1530
Elmo Rietschle 2BH1590
Elmo Rietschle 2BH1600
Elmo Rietschle 2BH1610
Elmo Rietschle 2BH1630
Elmo Rietschle 2BH1640
Elmo Rietschle 2BH1690
Elmo Rietschle 2BH1800
Elmo Rietschle 2BH1810
Elmo Rietschle 2BH1830
Elmo Rietschle 2BH1900
Elmo Rietschle 2BH1910
Elmo Rietschle 2BH1930
Elmo Rietschle 2BH1940
Elmo Rietschle 2BH1943