Induztr
Résumé technique Visionneuse de documents Modèles associés

Technical Data Sheet — L-BV2 compressor (EN)

Technical Reference Summary

Covered Models & Document Scope

Hoja de datos 2BV2 060, compresor de anillo líquido de la familia L-BV2, tamaño 2BV2 060. Variantes: fundición (estándar, RAL 9006) o acero inoxidable; variantes de código de material N, M, P, H, C; variantes de tensión/frecuencia K1, K6, Q02-3B, Q02-7B; versiones ATEX categoría 2G disponibles.

Technical Data

Parameter Value Condition
Suction capacity 0,20 m3/h p.2 ↗ 2BV2 060, 50 Hz
Rated power 1,75 kW p.2 ↗ 2BV2 060, 50 Hz
Rated power 2,0 kW p.2 ↗ 2BV2 060, 60 Hz
Service factor 1,00 SF p.2 ↗ 2BV2 060
Efficiency class IE3 - p.2 ↗ 2BV2 060, 50 Hz
Efficiency class NP - p.2 ↗ 2BV2 060, 60 Hz
Quantity of operating liquid 0,20 m3/h p.2 ↗ 2BV2 060
Sound pressure level 62 dB(A) p.2 ↗ 2BV2 060, 50 Hz
Sound pressure level 65 dB(A) p.2 ↗ 2BV2 060, 60 Hz
Weight 28 kg p.2 ↗ 2BV2 060
Voltage 190-210 V p.2 ↗ 2BV2 060, 50 Hz, K1, delta
Voltage 190-210 / 380-420 V p.2 ↗ 2BV2 060, 50 Hz, K1, YY/delta
Voltage 220-240 / 380-420 V p.2 ↗ 2BV2 060, 50 Hz, K6, delta/delta
Voltage 220-240 / 440-480 V p.2 ↗ 2BV2 060, 60 Hz, K6, YY/delta
Voltage 500 V p.2 ↗ 2BV2 060, 50 Hz, Q02-3B, delta
Voltage 575 V p.2 ↗ 2BV2 060, 60 Hz, Q02-3B, delta
Voltage 380-420 / 660-725 V p.2 ↗ 2BV2 060, 50 Hz, Q02-7B, delta/delta
Voltage 440-480 V p.2 ↗ 2BV2 060, 60 Hz, Q02-7B, delta
Current 6,9 A p.2 ↗ 2BV2 060, 50 Hz, 190-210 V delta
Current 7,8 / 3,9 A p.2 ↗ 2BV2 060, 50 Hz, 190-210 V YY / 380-420 V delta
Current 6,0 / 3,45 A p.2 ↗ 2BV2 060, 50 Hz, 220-240 V delta / 380-420 V delta
Current 6,8 / 3,4 A p.2 ↗ 2BV2 060, 60 Hz, 220-240 V YY / 440-480 V delta
Current 2,76 A p.2 ↗ 2BV2 060, 50 Hz, 500 V delta
Current 2,72 A p.2 ↗ 2BV2 060, 60 Hz, 575 V delta
Protection rating IP55 - p.2 ↗ 2BV2 060

Operating Limits

  • Protection rating: IP55 p.2 ↗
  • Insulation material class: F p.2 ↗
  • ATEX category available: 2G p.1 ↗
  • Intake temperature for characteristic curves: 20 °C p.1 ↗
  • Operating liquid temperature for characteristic curves: 15 °C p.1 ↗
  • Characteristic curve tolerance: ± 10 % p.1 ↗

Type Code Decoder

Position Token Meaning
1-4 p.2 ↗ 2BV2 Product family: liquid ring compressor L-BV2
5-7 p.2 ↗ 060 Size designation
material field p.3 ↗ N Material variant: cast iron casing with ceramic coating, bronze impeller, cast iron lantern
material field p.3 ↗ M Material variant: CrNi steel casing, CrNi steel impeller, CrNi steel lantern
material field p.3 ↗ P Material variant: CrNi steel casing, CrNi steel impeller, CrNi steel lantern (alternative seal)
material field p.3 ↗ H Material variant: cast chrome-nickel-molybdenum steel components
material field p.3 ↗ C Material variant: cast iron casing with ceramic coating, cast chrome-nickel-molybdenum steel impeller
voltage field p.2 ↗ K1 Voltage variant: 50 Hz 190-210 V delta / 190-210 V YY, 220-240 V delta / 380-420 V YY; 60 Hz 200 V YY / 230 V delta / 400 V Y
voltage field p.2 ↗ K6 Voltage variant: 50 Hz 190-210 V YY / 220-240 V delta / 380-420 V Y; 60 Hz 220-240 V YY / 440-480 V Y
voltage field p.2 ↗ Q02-3B Voltage variant: 50 Hz 500 V delta; 60 Hz 575 V delta
voltage field p.2 ↗ Q02-7B Voltage variant: 50 Hz 380-420 V delta / 660-725 V delta; 60 Hz 440-480 V delta