Technical Data Sheet — L-BV7 2BV7060 IE3 compressor (EN)
Technical Reference Summary
Covered Models & Document Scope
Familia de compresores de anillo líquido L-BV7, hoja de datos 2BV7 060. Abarca 2BV7060-2 y 2BV7060-3 en fundición (RAL 9006 estándar) y acero inoxidable (carcasa/placa de puertos de acero CrNi, rodete de bronce, linterna de fundición); variantes de tensión de 50 Hz y 60 Hz; variantes de eficiencia de motor IE3 y NP; versiones ATEX categoría 2G disponibles.
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Suction capacity | 62 m³/h p.2 ↗ | 2BV7060-2, 50 Hz, 1.30 kW |
| Suction capacity | 65 m³/h p.2 ↗ | 2BV7060-2, 50 Hz, 1.60 kW |
| Suction capacity | 65 m³/h p.2 ↗ | 2BV7060-3, 50 Hz, 1.75 kW |
| Suction capacity | 68 m³/h p.2 ↗ | 2BV7060-3, 50 Hz, 2.0 kW |
| Suction capacity | 65 m³/h p.2 ↗ | 2BV7060-2, 60 Hz, 1.60 kW |
| Suction capacity | 65 m³/h p.2 ↗ | 2BV7060-3, 60 Hz, 2.0 kW |
| Motor power | 1,30 kW p.2 ↗ | 2BV7060-2, 50 Hz |
| Motor power | 1,60 kW p.2 ↗ | 2BV7060-2, 60 Hz |
| Motor power | 1,75 kW p.2 ↗ | 2BV7060-3, 50 Hz |
| Motor power | 2,0 kW p.2 ↗ | 2BV7060-3, 60 Hz |
| Voltage | 190-210 V p.2 ↗ | 2BV7060-2, 50 Hz, Δ |
| Voltage | 380-420 V p.2 ↗ | 2BV7060-2, 50 Hz, Y |
| Voltage | 220-240 V p.2 ↗ | 2BV7060-2, 50 Hz, Δ |
| Voltage | 440-480 V p.2 ↗ | 2BV7060-2, 60 Hz, Y |
| Voltage | 500 V p.2 ↗ | 2BV7060-2, 50 Hz, Y |
| Voltage | 575 V p.2 ↗ | 2BV7060-2, 60 Hz, Y |
| Current | 5,6 A p.2 ↗ | 2BV7060-2, 50 Hz, 190-210 V Δ |
| Current | 6,3 A p.2 ↗ | 2BV7060-2, 50 Hz, 190-210 V Δ / 380-420 V Y |
| Current | 3,16 A p.2 ↗ | 2BV7060-2, 50 Hz, 380-420 V Y |
| Current | 7,8 A p.2 ↗ | 2BV7060-3, 50 Hz, 190-210 V Δ |
| Current | 3,9 A p.2 ↗ | 2BV7060-3, 50 Hz, 380-420 V Y |
| Service factor | 1,00 p.2 ↗ | all variants |
| Operating liquid level | 0,20 p.2 ↗ | all variants |
| Noise level | 62 dB(A) p.2 ↗ | 2BV7060-2, 50 Hz, 1.30 kW |
| Noise level | 68 dB(A) p.2 ↗ | 2BV7060-3, 50 Hz, 2.0 kW |
Operating Limits
- Protection category: IP55 p.1 ↗
- Intake temperature for characteristic curves: 20 °C p.1 ↗
- Operating liquid temperature (water) for characteristic curves: 15 °C p.1 ↗
- Characteristic curve tolerance: ± 10 % p.1 ↗
- ATEX category available: 2G (2006/42 EG) p.1 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-7 p.2 ↗ | 2BV7060 | Model range and size (2BV7, size 060) |
| 10-13 p.2 ↗ | K08-1B / K08-6B / Q08-7B / Q08-3B | Voltage/frequency variant code (mains connection and frequency) |
| field 3 p.2 ↗ | K | Voltage variant K: 50 Hz 190-210 V Δ / 380-420 V Y; 60 Hz 190-210 V Δ / 380-420 V Y |
| field 3 p.2 ↗ | Q | Voltage variant Q: 50 Hz 380-420 V Δ / 660-725 V Y; 60 Hz 440-480 V Δ |
| field 4 p.2 ↗ | 1 / 6 / 7 | Voltage range group: 1 = 190-210/380-420 V, 6 = 220-240/440-480 V, 7 = 380-420/660-725 V |
| field 5 p.2 ↗ | B | Design revision |