Operating Instructions — C-VLR 1000 vacuum pump (BA 880-80-EN, ed. 1.0 1.2.2017, EN)
Technical Reference Summary
Covered Models & Document Scope
This document is the original operating instructions (BA 880-80-EN, edition 1.0, 1.2.2017) for the C-VLR 1000 contact-free running claw vacuum pump (ZEPHYR VLR 1000), a single model/size in the C-Series. It covers the pump with standard flanged three-phase motor, plug connection or motor protection switch variants, and references separate supplier documents (data sheet D 880/80, spare parts list E 880/80, declaration of conformity C 0080-EN, declaration of harmlessness 7.7025.003.17, storage guidelines I 150). No ordering matrix or part-number code system is included.
Section-by-Section Technical Breakdown
Identifies component positions on the C-VLR 1000 (vacuum connection, exhaust silencer, cooling air in/out, oil filling point, sight glass, oil discharge, mesh filter, hot surfaces) and explains the contact-free dry claw operating principle with oil-lubricated synchronising gearbox and bearings. States the continuous operating pressure range and pumping capacity.
- Double-shaft rotary piston claw vacuum pump; counter-rotating claw rotors synchronised by an oil-lubricated gear pair; compression chamber separated from gearbox by special seals.
- Cooling by drum fan drawing fresh air between machine and insulating hood; hot surfaces > 70 °C marked (Fig. 2/Q).
- Driven by standard flanged three-phase motor via coupling; vacuum relief valve incorporated.
- Continuous operation possible at any pressure between atmospheric and 200 mbar (abs.) inlet pressure.
- Pumping capacity with unrestricted suction: 950 m3/h at 50 Hz.
- Frequent switching (about 10 times per hour) or high ambient/intake temperatures may exceed motor winding and bearing temperature limits; contact manufacturer.
- Outdoor installation requires protection from environmental influences, e.g. a protective roof.
Specifies installation clearances, horizontal mounting, foundation requirements, pipe connection rules including non-return valve and exhaust back-pressure limits, oil filling to sight-glass mid-level, and electrical connection requirements including motor protection and supply tolerances.
- Cooling air inlets/outlets must be at least 30 cm from adjacent walls; minimum 40 cm in front of the mesh filter for maintenance.
- Machine must be set up horizontally; foundation level, straight and able to take the machine weight; unanchored installation on a firm base possible, flexible buffers recommended on substructures.
- Power reduction noticeable above 1000 m above sea level; contact manufacturer.
- Do not operate without covering plates; install suction-side filters to protect from intake contamination.
- Screw pipes in by hand only; narrow and/or long suction pipes reduce pumping capacity.
- With connection pipes of the same cross-section and more than 3 m long, install a non-return valve to avoid reverse operation after stop.
- Exhaust air must not be restricted: no blocking systems in the exhaust pipe, max. pressure difference 30 mbar.
- Fill lubricating oil up to the middle of the sight glasses.
- Electrical installation per EN 60204 by a qualified electrician; motors per DIN EN 60034, IP 55, insulation class F.
- Motor protection switch required; delayed switch-off recommended because of temporary excess current during cold start.
- Without derating: ±5 % voltage deviation and ±2 % frequency deviation permissible.
Describes checks before start-up, rotation-direction verification, hot-surface and noise warnings, and the decommissioning/storage procedure including depressurisation and sealing of connections.
- Check rotation direction by briefly starting the motor (max. 2 seconds); looking at the motor fan it must rotate clockwise.
- Use a phase sequence indicator to check direction (anti-clockwise rotating field).
- Wrong rotation direction damages the machine.
- Machine must only be switched on again after it has stopped.
- Surface temperatures on marked components may exceed 70 °C at operating temperature; wear ear protectors for long stays near the running machine.
- Decommissioning: switch off, close suction/pressure cut-off devices if available, disconnect power, slowly open pipes to depressurise, remove pipes, seal connections with adhesive foil.
Provides the maintenance schedule (monthly checks, 8,000 h oil change, mesh filter cleaning, maintenance-free coupling), oil specification and change procedure, air filter cleaning, and repair/service and spare-parts requirements.
- Monthly: check pipes and screws for leaks and tightness, check terminal box and cable inlets for leaks, clean ventilation slots and motor cooling ribs, check oil level.
- Oil change every 8,000 operating hours with clean operation; change oil at operating temperature in a ventilated area.
- Oil specification: ISO VG 150 per DIN 51519; DIN 51502 designation CLP HC 150; recommended GEARLUBE 150 or equivalent.
- If switching oil type, completely empty the oil removing device housing and oil cooler.
- Mesh filter on inlet side cleaned by rinsing/purging or replaced depending on dirt load; wear goggles and dust mask when using compressed air.
- Coupling is maintenance-free.
- Repairs by manufacturer, branch offices or authorised dealers; a signed declaration of harmlessness must accompany every machine sent for service.
- Use only original or manufacturer-approved spare parts; spare parts list E 880/80.
Troubleshooting table mapping symptoms (motor protection trip, insufficient pumping capacity, final pressure not reached, overheating, abnormal noise) to causes and corrective actions.
- Motor protection switch tripping: check mains voltage/frequency against motor data, motor terminal board connection, and correct setting of the protection switch.
- Use a motor protection switch with overload-dependent delayed switch-off per VDE 0660 Part 2 or IEC 947-4 to accommodate start-up excess current.
- Insufficient pumping capacity: clean/replace dirty mesh filter, check suction pipe length and diameter, check for leaks.
- Final pressure not reached: check pipework and screw connections for leaks.
- Overheating: verify ambient/intake temperature within designated use, check cooling air supply and clean ventilation slots.
- Abnormal noise: deposits on the rotary piston; clean working space and rotary piston; contact Elmo Rietschle Service for other faults.
Lists sound pressure and sound power levels at 50 and 60 Hz, weight, dimensions, connection flange sizes and oil quantity for the C-VLR 1000. Refers to data sheet D 880/80 for further technical data.
- Sound pressure level (max., EN ISO 3744, tolerance ±3 dB(A)): 85 dB(A) at 50 Hz, 89 dB(A) at 60 Hz.
- Sound power level: 98 dB(A) at 50 Hz, 102 dB(A) at 60 Hz.
- Weight: 790 kg (may differ with motor manufacturer).
- Dimensions: length 1597 mm, width 666 mm, height 1123 mm.
- Vacuum connection: flange DN 100 PN 6; exhaust air outlet: flange DN 100 PN 10.
- Correct oil quantity: 2.8 l.
Key Integration, Operating & Safety Requirements
| Specification / Condition | Engineering Implication | S'applique à |
|---|---|---|
| Permitted ambient and suction temperature range is 5 to 40 °C. p.7 ↗ | Installations outside this range require consultation with the manufacturer; exceeding it risks overheating and warranty loss. | C-VLR 1000 |
| Continuous operation is permitted at any pressure between atmospheric and 200 mbar (abs.) inlet pressure. p.13 ↗ | The pump can be sized for permanent vacuum down to 200 mbar (abs.) without duty-cycle restrictions. | C-VLR 1000 |
| Pumping capacity with unrestricted suction is 950 m3/h at 50 Hz. p.13 ↗ | Base sizing figure for suction-line and system design at 50 Hz; capacity depends on intake pressure per data sheet D 880/80. | C-VLR 1000 |
| Cooling air inlets and outlets must be at least 30 cm from adjacent walls, and at least 40 cm must be kept free in front of the mesh filter for maintenance. p.14 ↗ | Defines minimum installation clearances to avoid recirculation of heated cooling air and to allow filter servicing. | C-VLR 1000 |
| With connection pipes of the same cross-section as the machine connection and longer than 3 m, a non-return valve must be installed. p.15 ↗ | Prevents reverse operation of the pump after shutdown when long suction lines are used. | C-VLR 1000 |
| Exhaust air must not be restricted; no blocking systems in the exhaust pipe, maximum pressure difference 30 mbar. p.15 ↗ | Exhaust piping and silencer must be sized for low back-pressure; connected exhaust pipes must be checked regularly for impurities. | C-VLR 1000 |
| Without derating, ±5 % voltage deviation and ±2 % frequency deviation from motor data plate values are permissible. p.16 ↗ | Supply quality must be verified against the motor data plate before commissioning; larger deviations require derating or manufacturer consultation. | C-VLR 1000 |
| Motors comply with DIN EN 60034, protection class IP 55 and insulation class F. p.16 ↗ | Suitable for dusty and hose-proof industrial environments; electrical installation must follow EN 60204. | C-VLR 1000 with standard flanged three-phase motor |
| A motor protection switch is required, preferably with overload-dependent delayed switch-off (VDE 0660 Part 2 or IEC 947-4). p.16 ↗ | Cold-start excess current can trip instantaneous protection; delayed overload protection avoids nuisance trips. | C-VLR 1000 |
| Rotation direction must be checked by briefly starting the motor (max. 2 seconds); the motor fan must rotate clockwise when viewed from the fan. p.18 ↗ | Wrong rotation direction damages the machine; use a phase sequence indicator to verify the anti-clockwise rotating field. | C-VLR 1000 |
| Oil must be changed every 8,000 operating hours with clean operation, at operating temperature and in an atmospherically ventilated area. p.20 ↗ | Defines the preventive maintenance interval for the gearbox and bearing lubrication; incomplete draining reduces refill quantity. | C-VLR 1000 |
| Oil viscosity must comply with ISO VG 150 per DIN 51519; DIN 51502 designation CLP HC 150; recommended GEARLUBE 150 or equivalent. p.20 ↗ | Only this oil class may be used; when changing oil type, completely empty the oil removing device housing and oil cooler. | C-VLR 1000 |
| Correct oil quantity is 2.8 l, filled to the middle of the sight glasses. p.25 ↗ | Oil level must be checked monthly; machine must be switched off and vented to atmospheric pressure before topping up. | C-VLR 1000 |
| Sound pressure level (max., EN ISO 3744, tolerance ±3 dB(A)) is 85 dB(A) at 50 Hz and 89 dB(A) at 60 Hz; sound power level is 98 dB(A) at 50 Hz and 102 dB(A) at 60 Hz. p.25 ↗ | Ear protection is required for long stays near the running machine; acoustic planning should use the sound power level. | C-VLR 1000 |
| Vacuum connection is flange DN 100 PN 6; exhaust air outlet is flange DN 100 PN 10. p.25 ↗ | Piping and mating flanges must be selected to these standards; pipes must be screwed in by hand only to avoid excessive forces on the unit. | C-VLR 1000 |
| Weight is 790 kg; dimensions are 1597 mm length, 666 mm width and 1123 mm height (weight and length may differ with motor manufacturer). p.25 ↗ | Foundation and lifting equipment must be sized for at least this weight; verify actual motor data before final rigging. | C-VLR 1000 |
| Storage conditions: relative humidity 0-80 %, storage temperature -10 to +60 °C, dust-free and vibration-free, maximum 6 months. p.11 ↗ | Long-term storage beyond 6 months or outside these conditions requires the separate storage guidelines I 150 and re-commissioning checks. | C-VLR 1000 |
| Above 1000 m above sea level a reduction in power is noticeable. p.14 ↗ | High-altitude installations require motor derating or manufacturer consultation to avoid overload. | C-VLR 1000 |
| Frequent switching at regular intervals of about 10 times per hour, or high ambient/intake temperatures, may exceed the excess-temperature limit of the motor winding and bearings. p.13 ↗ | Duty cycle and thermal environment must be reviewed with the manufacturer for such applications. | C-VLR 1000 |
| Hot surfaces marked in Fig. 2/Q may exceed 70 °C at operating temperature. p.8 ↗ | Guards must prevent access to hot parts during operation; maintenance work must wait for cool-down. | C-VLR 1000 |