Operating Instructions — C-DLR 401 compressor (BA 888-EN, ed. 1.1 20.6.2018, EN)

Technical Reference Summary

Covered Models & Document Scope

This document covers the contact-free running claw compressors C-DLR 401 and C-DLR 501 (C-Series, claw design). Both models share the same design and differ in flow rate (400 m3/h and 500 m3/h at 50 Hz), weight, dimensions and sound power level. A special version with sealing gas loading of the atmospherically ventilated area between gearbox and compression chamber is mentioned.

Section-by-Section Technical Breakdown

pp. 12-13
Set up and operation

Describes the machine layout and component identification (suction, pressure connection, safety valve, cooling air inlet/outlet, oil filling point, oil sight glass, oil discharge point, data plate, direction of rotation arrow, suction filter, intake silencer), the data plate contents, the functional description of the double-shaft claw compressor, and the areas of application. It states the permissible pressure range, flow rates and operating conditions.

  • C-DLR 401 and C-DLR 501 are double-shaft rotary piston compressors with contact-free, dry claw rotors synchronised by an oil-lubricated gear pair.
  • Gearbox and compression chamber are separated by special seals; an atmospherically ventilated intermediate area can be loaded with sealing gas (special version).
  • Cooling is by a drum fan drawing fresh air between machine and insulating hood.
  • Driven by standard flanged three-phase motors via a coupling; safety valve fitted as standard.
  • Suitable for creating excess pressure between 0 and the maximum limit given on the data plate; constant operation permissible.
  • Flow rates 400 m3/h (C-DLR 401) and 500 m3/h (C-DLR 501) at 50 Hz.
  • Frequent switching (about 10 times an hour) or high ambient/intake temperatures may exceed motor winding and bearing temperature limits; contact manufacturer.
  • Outdoor installation requires protection from environmental influences (e.g. protective roof).
pp. 14-16
Installation

Covers preparation for installation, mounting requirements, pipe connection, safety valve, oil filling and motor connection. It specifies clearances, foundation conditions, pipe length rules, electrical protection requirements and permissible voltage/frequency deviations.

  • Machine must be freely accessible from all sides; ventilation grids and holes must not be closed.
  • Cooling air inlets and outlets must be at least 30 cm from adjacent walls; cooling air must not be recirculated.
  • Minimum 40 cm in front of inlet filter and inlet silencer for maintenance.
  • Machine must be set up horizontally; foundation level and straight, able to take the machine weight.
  • Installation on a firm base without anchoring is possible; on a substructure fixing with flexible buffers is recommended.
  • Power reduction noticeable above 1000 m above sea level; contact manufacturer.
  • Do not operate without covering plates.
  • Pressure connection: only screw pipes in by hand; too narrow and/or too long pressure pipe reduces volume flow.
  • With connection pipes of same cross-section as machine connection and more than 3 m long, a non-return valve must be installed to avoid reverse operation when stopped.
  • Safety valve is a wear part and must be replaced after 10,000 hours or no more than 2 years.
  • Fill lubricating oil up to the middle of the sight glass.
  • Electrical installation only by qualified electrician observing EN 60204; operating company provides main switch.
  • Motors comply with DIN EN 60034, protection class IP 55, insulation class F.
  • Motor protection switch required; delayed switch-off recommended due to temporary excess current at cold start.
  • Without derating: ±5 % voltage deviation and ±2 % frequency deviation permissible.
pp. 17-18
Commissioning and decommissioning

Describes commissioning checks including rotation direction, safety notes for hot surfaces and noise, decommissioning/storing procedure and re-commissioning. It specifies the correct rotation direction and the need to wait until the machine stops before restarting.

  • Surface temperatures on marked components may exceed 70 °C at operating temperature.
  • Highest noise pressure levels per EN ISO 3744 are given in Section 9; ear protectors recommended for long stays near running machine.
  • Machine must only be switched on again after it stops.
  • Intended direction of rotation shown by arrow; when looking at the motor fan it must rotate anti-clockwise.
  • Start motor briefly (max. two seconds) to check rotation direction; use a phase sequence indicator (clockwise rotating field).
  • Wrong direction of rotation leads to machine damage.
  • Decommissioning: switch off, close cut-off devices if available, disconnect from electricity, depressurise slowly, remove pipes/hoses, seal connections with adhesive foil.
  • Re-commissioning: check condition (cleanliness, cabling etc.) and follow installation and commissioning sections.
pp. 19-23
Maintenance and repair

Provides the maintenance schedule, oil change procedure, air filter cleaning/replacement, repair/service requirements and spare parts ordering information. It includes intervals for leak checks, safety valve replacement, oil level check, oil change and filter maintenance.

  • Monthly: check pipes and screws for leaks and proper seating; check terminal box and cable inlet holes for leaks; clean safety valve and ventilation slots/motor cooling ribs; check oil level.
  • Every 10,000 h: replace safety valve.
  • Every 20,000 h: change oil.
  • Monthly or every 6 months: clean or replace filter cartridge.
  • Clean micro filter depending on how dirty the discharged medium is.
  • Change oil at operating temperature and in an atmospherically ventilated area; incomplete emptying reduces refill amount.
  • If changing oil type, empty oil removing device housing and oil cooler completely.
  • Recommended oil: Elmo Rietschle GEAR-LUBE 150 synthetic oil; viscosity must comply with ISO VG 150 as per DIN 3448.
  • Oil level in sight glasses must be checked every month; top up with machine switched off and vented to atmospheric pressure.
  • Filter cartridge cleaned monthly or more often by purging from inside outwards; replace every six months.
  • Filter cartridge removed after undoing tension clamps.
  • Wear goggles and dust mask when cleaning with compressed air.
  • For repairs use manufacturer, branch offices or authorised dealers; enclose signed declaration of harmlessness for machines sent to service centre.
  • After repair or re-commissioning, carry out installation and commissioning actions as for initial commissioning.
  • Order spare parts per spare parts list E 888; only use original or approved parts.
pp. 26
Technical Data

Lists key technical data for C-DLR 401 and C-DLR 501 including sound pressure and sound power levels, weight, dimensions, pressure connection and oil quantity. More data is available in data sheet D 889.

  • Sound pressure level (max.) EN ISO 3744, tolerance ±3 dB(A): 50 Hz 86 dB(A) for both models; 60 Hz 86 dB(A) for 401 and 87 dB(A) for 501.
  • Sound power level: 50 Hz 99 dB(A) (401) and 101 dB(A) (501); 60 Hz 99 dB(A) (401) and 102 dB(A) (501).
  • Weight: 510 kg (401), 576 kg (501).
  • Length: 1295 mm (401), 1359 mm (501).
  • Width: 742 mm (401), 747 mm (501).
  • Height: 1123 mm (401), 1128 mm (501).
  • Pressure connection: G 3.
  • Correct amount of oil: 1.85 l.
  • Length and weight may differ depending on motor manufacturer.

Key Integration, Operating & Safety Requirements

Specification / Condition Engineering Implication S'applique à
Ambient and suction temperature must be between 5 and 40 °C. p.7 ↗ Operation outside this range requires consultation with the manufacturer; ensure installation environment stays within limits. C-DLR 401 and C-DLR 501
Cooling air inlets and outlets must be at least 30 cm away from adjacent walls. p.14 ↗ Maintain clearance to avoid recirculation of heated air and ensure adequate cooling. C-DLR 401 and C-DLR 501
Minimum 40 cm clearance in front of inlet filter and inlet silencer for maintenance. p.14 ↗ Plan installation layout to allow filter removal and maintenance access. C-DLR 401 and C-DLR 501
With connection pipes of same cross-section as machine connection and more than 3 m long, a non-return valve must be installed. p.15 ↗ Prevents reverse operation when the machine stops; include non-return valve in piping design for long lines. C-DLR 401 and C-DLR 501
Safety valve must be replaced after 10,000 hours or no more than 2 years. p.15 ↗ Include safety valve in scheduled maintenance; it is a wear part. C-DLR 401 and C-DLR 501
Without derating, voltage deviation ±5 % and frequency deviation ±2 % are permissible. p.16 ↗ Verify site power quality against motor data plate; outside these limits requires derating or consultation. C-DLR 401 and C-DLR 501
Motors comply with DIN EN 60034, protection class IP 55, insulation class F. p.16 ↗ Suitable for dusty and humid environments within IP 55; ensure cable entries are sealed. C-DLR 401 and C-DLR 501
When looking at the motor fan, it must rotate anti-clockwise; use a phase sequence indicator (clockwise rotating field). p.18 ↗ Incorrect rotation direction damages the machine; verify phase sequence before commissioning. C-DLR 401 and C-DLR 501
Oil change interval: every 20,000 operating hours with clean operations. p.20 ↗ Plan oil changes at 20,000 h; use Elmo Rietschle GEAR-LUBE 150 or ISO VG 150 oil. C-DLR 401 and C-DLR 501
Oil viscosity must comply with ISO VG 150 as per DIN 3448. p.20 ↗ Select only compatible oil; if changing oil type, empty oil removing device housing and oil cooler completely. C-DLR 401 and C-DLR 501
Filter cartridge must be cleaned monthly or more often by purging from inside outwards; replace every six months. p.21 ↗ Insufficient air filter maintenance reduces power and may damage the machine. C-DLR 401 and C-DLR 501
Correct amount of oil: 1.85 l. p.26 ↗ Fill to middle of sight glass; use as reference for oil fill volume. C-DLR 401 and C-DLR 501
Pressure connection: G 3. p.26 ↗ Pipe connection must match G 3 thread; screw pipes in by hand only. C-DLR 401 and C-DLR 501
Sound pressure level (max.) at 50 Hz: 86 dB(A) for both models; at 60 Hz: 86 dB(A) for 401 and 87 dB(A) for 501. p.26 ↗ Use ear protection for prolonged presence near running machine. C-DLR 401 and C-DLR 501
Weight: 510 kg (C-DLR 401), 576 kg (C-DLR 501). p.26 ↗ Foundation and lifting equipment must be sized accordingly; length and weight may differ depending on motor manufacturer. C-DLR 401 and C-DLR 501
Flow rates: 400 m3/h (C-DLR 401) and 500 m3/h (C-DLR 501) at 50 Hz. p.13 ↗ Select model based on required volume flow; flow rate depends on excess pressure per data sheet D 889. C-DLR 401 and C-DLR 501
Above 1000 m above sea level a reduction in power is noticeable. p.14 ↗ Contact manufacturer for high-altitude installations; account for reduced performance. C-DLR 401 and C-DLR 501
Frequent switching (about 10 times an hour) or high ambient/intake temperatures may exceed motor winding and bearing temperature limits. p.13 ↗ Contact manufacturer if such conditions apply; may require special measures. C-DLR 401 and C-DLR 501

Faults & Troubleshooting

Code / Symptôme Possible Cause Remedy Note
Machine is switched off by the motor protection switch p.24 ↗ Mains voltage/ Frequency does not correspond with the motor data Check by qualified electrician Section 5.5
Machine is switched off by the motor protection switch p.24 ↗ Connection to motor terminal board is not correct Check by qualified electrician Section 5.5
Machine is switched off by the motor protection switch p.24 ↗ Motor protection switch is not set correctly Check by qualified electrician Section 5.5
Machine is switched off by the motor protection switch p.24 ↗ Motor protection switch is triggered too quickly Use a motor protection switch with an overload-dependent delayed switch off that takes into consideration the short term excess current at start up (version with short circuit and overload trigger as per VDE 0660 Part 102 or IEC 60947-4-1)
Machine is switched off by the motor protection switch p.24 ↗ The safety valve is dirty so that the permissible pressure is exceeded. Clean or replace the safety valve Section 7.2, Section 7.4
Blowing capacity is insufficient p.24 ↗ The suction filter is dirty Clean or replace the suction filter Section 7.2.2, Section 7.4
Blowing capacity is insufficient p.24 ↗ The pressure line is too long or too narrow Check the hose or the pipe Section 5.3
Blowing capacity is insufficient p.24 ↗ Machine or system leaking Check the pipework and screw connections for leaks and to ensure that they are firmly seated. Section 7.2
Final pressure (max excess pressure) has not been reached p.25 ↗ Machine or system leaking Check the pipework and screw connections for leaks and to ensure that they are firmly seated. Section 7.2
Final pressure (max excess pressure) has not been reached p.25 ↗ Driving power selection too low Use next largest motor output Data sheet D 889
Machine gets too hot p.25 ↗ Ambient or intake temperature is too high Ensure it is being used properly Section 2.3
Machine gets too hot p.25 ↗ Cooling air supply is obstructed Check environmental conditions Section 5.1
Machine gets too hot p.25 ↗ Cooling air supply is obstructed Clean ventilation slots Section 7.2
Machine gets too hot p.25 ↗ The safety valve is dirty so that the permissible pressure is exceeded. Clean or replace the safety valve Section 7.2, Section 7.4
The machine makes a abnormal noise p.25 ↗ Deposits on the rotary piston Clean the working space and the rotary piston Elmo Rietschle Service
The machine makes a abnormal noise p.25 ↗ The safety valve is vibrating Replace the valve Section 7.4