Technical Data Sheet — C-VLR 50 vacuum pump DE/EN)
Technical Reference Summary
Covered Models & Document Scope
Bomba de vacío de garras C-VLR 1000 (F001) con convertidor de frecuencia integrado, 50/60 Hz, 3~ 400–480 V
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Suction capacity | 475 - 950 m3/h p.2 ↗ | C-VLR 1000 (F001) |
| Ultimate vacuum at continuous operation | 200 mbar (abs.) p.2 ↗ | C-VLR 1000 (F001) |
| Connection voltage frequency converter | 400 (-15 %) - 480 V (+10 %) (50 - 60 Hz) V p.2 ↗ | C-VLR 1000 (F001) |
| Current drawn frequency converter | 39,9 A p.2 ↗ | C-VLR 1000 (F001) |
| Motor rating | 22,0 kW p.2 ↗ | C-VLR 1000 (F001) |
| Rated voltage motor | 400 V p.2 ↗ | C-VLR 1000 (F001), 3~ |
| Cut-off frequency motor | 60 Hz p.2 ↗ | C-VLR 1000 (F001) |
| Current drawn motor | - A p.2 ↗ | C-VLR 1000 (F001) |
| Speed | 1500 - 3000 (25 Hz - 50 Hz) min-1 p.2 ↗ | C-VLR 1000 (F001) |
| Average noise level | 78 - 82 dB(A) p.2 ↗ | C-VLR 1000 (F001), EN ISO 3744 |
| Max. weight | 757 kg p.2 ↗ | C-VLR 1000 (F001) |
| Oil capacity | 2,8 l p.2 ↗ | C-VLR 1000 (F001) |
| Protection class | IP 55 p.2 ↗ | C-VLR 1000 (F001) |
| Motor protection | PTC Sensor p.2 ↗ | C-VLR 1000 (F001) |
Operating Limits
- Ultimate vacuum at continuous operation: 200 mbar (abs.) p.2 ↗
- Connection voltage frequency converter tolerance: 400 (-15 %) - 480 V (+10 %) p.2 ↗
- Speed range: 1500 - 3000 min-1 (25 Hz - 50 Hz) p.2 ↗
- Protection class: IP 55 p.2 ↗