Technical Data Sheet — C-VLR 301 vacuum pump DE/EN)
Technical Reference Summary
Covered Models & Document Scope
Bomba de vacío C-VLR 301, datos nominales a 50 Hz; valores a 60 Hz no indicados. Variantes de tensión C-VLR X01 xx VI, SI, Wx, Ux, Tx para otras tensiones (50/60 Hz, Δ/Y).
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Suction capacity | 290 m³/h p.2 ↗ | C-VLR 301, 50 Hz |
| Suction capacity | – m³/h p.2 ↗ | C-VLR 301, 60 Hz |
| Ultimate vacuum at continuous operation | 150 mbar (abs.) p.2 ↗ | C-VLR 301 |
| Rated voltage | 400 / 690 V ± 10 % p.2 ↗ | C-VLR 301, 3~, 50 Hz |
| Rated voltage | – V p.2 ↗ | C-VLR 301, 60 Hz |
| Motor rating | 5,5 kW p.2 ↗ | C-VLR 301, 50 Hz |
| Motor rating | – kW p.2 ↗ | C-VLR 301, 60 Hz |
| Current drawn | 10,2 / 5,89 A p.2 ↗ | C-VLR 301, 50 Hz |
| Current drawn | – A p.2 ↗ | C-VLR 301, 60 Hz |
| Motor efficiency | 90,9 % p.2 ↗ | C-VLR 301, 50 Hz |
| Motor efficiency | – % p.2 ↗ | C-VLR 301, 60 Hz |
| Speed | 2935 min⁻¹ p.2 ↗ | C-VLR 301, 50 Hz |
| Speed | – min⁻¹ p.2 ↗ | C-VLR 301, 60 Hz |
| Average noise level | 74 dB(A) p.2 ↗ | C-VLR 301, EN ISO 3744, 50 Hz |
| Average noise level | – dB(A) p.2 ↗ | C-VLR 301, EN ISO 3744, 60 Hz |
| Max. weight | 294 kg p.2 ↗ | C-VLR 301 |
| Oil capacity | 1,5 l p.2 ↗ | C-VLR 301 |
| Motor protection switch | 160 / 63 p.3 ↗ | C-VLR 301, 50 Hz |
Operating Limits
- Voltage tolerance: ±10 % p.2 ↗
- Ultimate vacuum at continuous operation: 150 mbar (abs.) p.2 ↗
- Max. weight: 294 kg p.2 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-5 p.2 ↗ | C-VLR | Product series (vacuum pump) |
| 6-8 p.2 ↗ | 301 | Size / type designation |
| 9-10 p.2 ↗ | X01 | Version field (as printed in voltage variant table) |
| 11-12 p.2 ↗ | xx | Placeholder for option/variant field |
| 13-14 p.2 ↗ | VI | Voltage variant: 200 V Δ / 346 V Y (50 Hz) |
| 13-14 p.2 ↗ | SI | Voltage variant: 200 V Δ / 230 V Δ / 400 V Y (50 Hz) |
| 13-14 p.2 ↗ | Wx | Voltage variant: no values printed |
| 13-14 p.2 ↗ | Ux | Voltage variant: 330 V Δ / 380 V Δ / 660 V Y (50 Hz) |
| 13-14 p.2 ↗ | Tx | Voltage variant: 200 V Δ / 400 V Δ / 690 V Y (50 Hz) |