Unistat Operation Manual

Sommaire

  1. Overview p. 8
    Document structure and section listing
  2. Overview p. 9
    Operating principles and functional overview of the unit
  3. Procedure p. 10
    Configuration and parameter setup procedures
  4. Procedure p. 11
    Communication interfaces and firmware update instructions
  5. p. 12
    Supplementary information and appendices
  6. Overview p. 13
    Preface, safety notes and document conventions
  7. Overview pp. 14-21
    Product introduction, intended use and technical basics
  8. Procedure pp. 22-37
    Installation, initial start-up and commissioning steps
  9. Overview pp. 38-50
    Detailed functional description of operating modes
  10. Procedure pp. 51-75
    Detailed setup, calibration and configuration procedures
  11. Procedure pp. 76-77
    Standard operating procedures during normal use
  12. Procedure pp. 78-85
    Interface configuration and software update details
  13. Procedure pp. 86-95
    Maintenance, servicing and troubleshooting procedures
  14. Procedure pp. 96-99
    Safe shutdown and decommissioning instructions
  15. Spec pp. 100-102
    Operating temperature range and technical specifications
  16. p. 10 table, 40 rows
  17. p. 48 table, 13 rows
  18. p. 41 table, 8 rows
  19. p. 49 table, 14 rows
  20. p. 88 table, 12 rows
  21. p. 28 table, 6 rows
  22. p. 39 table, 8 rows
  23. p. 43 table, 7 rows
  24. p. 82 table, 3 rows
  25. p. 84 table, 6 rows

Содержание (оглавление) раздела 4 Setup mode и раздела 5 Normal operation

РазделНазваниеСтраница
4Setup mode51
4.1Setup mode51
4.1.1Turning on the temperature control unit51
4.1.2Turning off the temperature control unit51
4.1.3Setting the overtemperature protection52
4.1.3.1General information on the overtemperature protection52
4.1.3.2Setting “OT limit: heating”52
4.1.3.3Setting “OT expansion vessel”53
4.1.3.4Setting “Process Safety”53
4.1.3.5Monitoring via “Display OT values”53
4.1.4Testing overtemperature protection for functionality54
4.1.5Adjusting the Delta T limiter54
4.1.5.1Changing the Delta T limiter54
4.2The temperature control circuit54
4.2.1Select temperature control: Internal or process55
4.2.2Temperature control to internal temperature55
4.2.3Temperature control to process temperature56
4.2.4Delta T limiter56
4.2.5Monitoring the Pt100 temperature sensors56
4.2.6Optimum control parameters for optimum temperature control57
4.2.7Sub-category: “Select auto/expert mode”.57
4.2.8Sub-category: “Configuration auto”57
4.2.8.1Sub-category: “Find parameters”57
4.2.8.2Sub-category: “Control Dynamics”59
4.2.8.3Sub-category: “Fluid Properties”60
4.2.8.4Sub-category: “Display parameters”61
4.2.9Sub-category: “Configuration manual”62
4.2.9.1Sub-category: “Change parameters”62
4.2.9.2Sub-category: “Display parameters”63
4.2.9.3Sub-category: “Control structure”63
4.2.10Sub-category: “Reset parameters”63
4.2.11Sub-category: “Display parameters”64
4.2.12Setting the setpoint thresholds64
4.2.13Setting the setpoint65
4.3Adjusting the cooling capacity65
4.3.1Cooling water connection66
4.4Filling, venting, degassing and draining66
4.4.1Externally closed application66
4.4.1.1Filling and venting externally closed application67
4.4.1.2Degassing externally closed applications68

Restore factory settings — “X” = Value is reset, “–” = Value is not reset

Description(A)(B)(C)(D)(E)(F)
AcousticsXXX–––
Display functions Warnings; Messages; Inactive Menu Items; Resolution TemperatureXXX–––
Display modesXXX–––
AutoStart responseXXX–––
Limitations DeltaT limit; max. heating variable; max. cooling variable; max. permissible current consumption (for 230 V temperature control units)XXX–––
Com.G@te (only if Com.G@te is connected) Analog Interface (configuration input) Meaning of AIF input; response on cable break; measurement range settingXXX––X
Calibration–––––X
In case of analog error; current / voltage switching; filter constantXXX––X
Configuration Output AIF output variable; Output range settingXXX––X
Calibration–––––X
RS232/RS485 (Hardware RS, Baud rate, device address); ECS Standby; POKO AlarmXXX–––
Properties (other) Change thermal fluid (thermal fluid, liter indicator, bypass usage); cooling bath / cooling (CC-E only)XXX–––
Sensor calibration––––––

(A) = All together; (B) = Device parameters without OT; (C) = Device Parameter; (D) Program Controller; (E) = Menu; (F) = Com.G@te

Overview of the E-grade variants

Temperature control units / E-gradeE-grade BasicE-grade ExclusiveE-grade Professional
Brewing thermostats–XO
Unistat temperature control units––X
UniCAL––X
Other temperature control unitsXOO
E-grade “Explore” (only for “Unistat”-series temperature control units)
The E-grade includes E-grade “Professional” functionalities. In addition it includes: – Sensor calibration for return sensor – Return temperature display – Display of performance (estimated or calculated from volume flow) – Display mode “Explore” instead of “numerically large” – PB commands correspond to DV-E-grade, except: Temperatures only in 0.01 °C and volume flows only in 0.1 l/min.––O
E-grade “DV-E-grade” – All interface commands are enabled. – Temperatures in 0.001 C, volume flows in 0.001 l/min possible (cf. E-grade Explore) Note: Only the interface commands are enabled, not the corresponding menu items in Pilot ONE!OOO
E-grade “OPC-UA” – OPC-UA interface via Ethernet. This E-grade additionally includes DV-E-grade functionalities.OOO

X = Standard equipment, O = optional, – = not possible

Configuration manual parameters

Description(A)(B)(C)(D)(E)(F)
Automated compressorXXX–––
Enter programX––X––
Pump settings Pump speed setpoint; Pump pressure setpoint; Control ModeXXX–––
Fluid properties Thermal fluid; liter indicatorXXX–––
Protective function High Limit Alarm Internal; Low Limit Alarm Internal; High Limit Alarm Process; Low Limit Alarm Process; Hydrostatic Correction; Warning Time Limit (CC-E only); Min. Level (for temperature control units with analogue level sensor); Max. Level (for temperature controllers with analogue level sensor); Freeze Protection (optional)XXX–––
SetpointXXX–––
Setpoint limitation Min. Setpoint; Max. SetpointXXX–––
LanguageXXX–––
Temperature formatXXX–––
Temperature control modeXXX–––
Favourites menuX–––X–
Pilot ONE Ethernet IP address; Subnet Mask; Remote AccessXXX–––
Time formatXXX–––
2. SetpointXXX–––

Cooling*

DescriptionMaintenance intervalCommentPerson responsible
A/WCheck the power cablePrior to switching on the temperature control unit or on relocationDo not start the temperature control unit if the power cable is damaged.Qualified electrician (BGV A3)
AClean the perforated sheetAs requiredClean the perforated sheet of the temperature control unit with a damp clothOperating company
A/WThermal fluid inspectionAs required–Operating company and / or operators
UEmpty drip tray1Monthly→ Page 91, section »Emptying the drip tray (if present)«.Operating company and / or operators
A/WCheck the mechanical seals (drip tray) 1Monthly→ Page 95, section »Inspect the mechanical seal«.Operating company and / or operators
ACheck the liquefier finsAs required, after 3 months at the latest→ Page 89, section »Clean liquefier fins (air-cooled temperature control unit)«.Operating company and / or operators
WCheck the hat-type strainer (dirt trap)As required, after 3 months at the latest→ Page 90, section »Clean hat-type strainer (dirt trap) (water-cooled temperature control unit)«.Operating company and / or operators
A/WOvertemperature protection (OT) - functional checkEvery month or after changing the thermal fluid→ Page 54, section »Testing overtemperature protection for functionality«.Operating company and / or operators
A/WCheck the temperature control unit for damage and stabilityEvery 12 months or after a change of location–Operating company and / or operators
WCheck the cooling water qualityEvery 12 monthsDescale the cooling water circuit as required. Documentation on water quality is available at: www.huber-online.comOperating company and / or operators
A/WFree-standing models: Check air filter matsDetermine according to ambient conditions.Check all air filter mats of the temperature control unit. Replace the air filter mats as needed. → Page 17, section »Proper disposal of resources and consumables«.Operating company and / or operators
A/WExchange safety-relevant electric and electromechanical components20 yearsHave the exchange only carried out by certified personnel (such as Huber service engineers). Please contact Customer Support. → Page 99, section »Contact data«.Operating company

*A = Air cooling; W = Water cooling; U = Applicable only for Unistats 1 Not valid for magnetically coupled circulation pumps (entry "MC pump" in technical data sheet). Magnetically coupled circulation pumps are maintenance-free. Circulation pumps with mechanical seal have no entry under "Circulation pump" in the technical data sheet.

Side / Distance in cm (for operation in a tub)

SideAir coolingWater cooling
[A1] TopAir outlet on top of unit: free standing–
[A2] Topcan be located under a benchcan be located under a bench
[B] Leftmin. 20min. 20
[C] Rightmin. 20min. 20
[D] Frontmin. 20min. 20
[E] Rearmin. 20min. 20

Designation / Specification

DesignationSpecification
Calcium carbonate per liter≤ 1.5 mmol/l; corresponds to a water hardness of: ≤ 8.4 °dH (soft)
PH valuebetween 6.0 and 8.5
Ultrapure water, distillatesAdd 0.1 g of sodium carbonate (Na2CO3) per liter
Not approved waterDistilled, deionized, demineralized, chloric, ferruginous, ammoniacal, or contaminated river water or sea water
Thermal fluid: Water without ethylene glycol
Use(+15) +65 °C to +90 °C
Thermal fluid: Water-ethylene glycol mixture
Usedo not use

Function description

FunctionE-grade BasicE-grade ExclusiveE-grade Professional
Storage/loading temperature control programs onto USB stick–XX
Copying settings––X
Service data recorders (flight recorder)XXX
PB commands1XXX
Communication Watchdog––X
Process data recording directly to a USB stick: Setpoint, Actual Value Internal and Actual Value Process / Heating Capacity %, Cooling Capacity %, and Pump Pressure / Pump Speed, and VPC Pressure–/–/–X/X/–X/X/X
Calendar start––X

1 See Data Communication Manual. Anything controllable via the graphical user interface of the Pilot ONE can be controlled by PB commands.

Female RS232 Serial (with adapter cable) — pin assignment

PinSignalDescription
2RxDReceive Data
3TxDTransmit Data
5GNDSignal GND

Jack AIF Reg-E-Prog

PinDescriptionSignal
1Current output, T external0 a)/4 - 20 mA or 0 - 10 V If using 0 - 10 V, integrate a 500 Ω resistor.
2Current output, setpoint0 a)/4 - 20 mA or 0 - 10 V
3GND for analog outputsGND
4Analog input (programmable)0 a)/4 - 20 mA or 0 - 10 V Power input: 200 Ω working resistance Voltage input: 100 kΩ input resistance
5Current output, freely programmable0 a)/4 - 20 mA or 0 - 10 V If using 0 - 10 V, integrate a 500 Ω resistor.
6GND for analog inputGND

a)Consult with our Customer Support.

Engineering Facts

14 facts · every claim linked to a page
Safety

The unit must not be installed or started inside an ATEX zone; explosion protection requires an Ex px cabinet.

Determines whether the unit can be placed in a hazardous area at all.

Source
“Do NOT install or start up the temperature control unit within an ATEX zone.”
Installation

The unit must be transported and stored upright only; horizontal transport damages the compressor.

Affects rigging, pallet handling and site logistics during installation.

Source
“Only transport the temperature control unit in an upright position.”
Installation

Only an emptied unit may be moved; filled transport risks thermal fluid overflow.

Dictates drain-before-move procedure and spill risk planning.

Source
“Only transport an emptied temperature control unit.”
Installation

Casters are not for transport and carry only 25% of total mass symmetrically; use an industrial truck.

Prevents using casters for relocation and informs floor/rigging planning.

Source
“The casters (if present) on the temperature control unit are not suitable for transport.”
Installation

Leveling feet must be unscrewed/activated and parking brakes engaged before commissioning.

Ensures stable, level installation and prevents creeping during operation.

Source
“The parking brakes at the casters (if present) must be activated and/or the leveling feet (if pre-sent) must be unscrewed/activated before the temperature control unit is put into operation.”
Installation

Allow about 2 hours acclimation when moving between cold and warm environments before power-on.

Prevents condensation-induced electrical faults at first start-up.

Source
“Allow the temperature control unit to acclimate for about 2 hours when changing from a cold to a warm environment (or vice versa). Do not turn on the temperature control unit before!”
Installation

For externally closed applications the expansion vessel must remain unlocked; locking it causes overpressure damage.

Critical valve setting depending on whether the application is open or closed.

Source
“Locking the >Expansion vessel< [18] will damage the externally closed application due to overpressure.”
Installation

For externally open applications the expansion vessel must be locked to prevent fluid loss.

Prevents leakage and ensures correct volume compensation for bath applications.

Source
“The >Expansion vessel< [18] must be locked!”
Installation

Hard-wired power connection must be done by an electrician; supply voltage/frequency must match the rating plate.

Defines qualification requirement and verification step for electrical hook-up.

Source
“Have the connection/adjustment to the power supply carried out by an electrician.”
Installation

At 230 V the max current is just under 16 A and the unit can be limited to 13 A or 10 A at first start-up.

Determines upstream fuse/breaker sizing and possible power derating.

Source
“The maximum current consumption at 230 V operation is just below 16 A.”
Operation

Process Safety mode requires the compressor set to Permanently ON to keep cooling active at the OT trigger.

Affects controller configuration for exothermic process protection.

Source
“This mode requires the compressor to be set to Permanently ON”
Operation

Power Failure Auto resumes temperature control automatically after a power outage if it was active.

Influences restart strategy and unattended operation risk assessment.

Source
“If temperature control is active during a power outage, the process will automatically continue after the power outage.”
Maintenance

Cooling water supply should be shut off even for short downtimes such as overnight.

Prevents water damage and unnecessary load on the cooling water circuit.

Source
“Shut off the cooling water supply to the temperature control unit even for shorter downtimes (e.g. overnight).”
Maintenance

Hoses and connections must be periodically checked for leaks and quality and replaced as needed.

Defines the preventive maintenance interval scope for the fluid circuit.

Source
“Check periodically for leaks and the quality of the hose and hose connections and take suitable measures (replace) as required.”

Modèles liés

Peter Huber Kältemaschinenbau Unistat 1005w Dynamisches Peter Huber Kältemaschinenbau Unistat 1015w Dynamisches Peter Huber Kältemaschinenbau Unistat 410w Dynamisches Peter Huber Kältemaschinenbau Unistat 425w Dynamisches Peter Huber Kältemaschinenbau Unistat 430w Dynamisches Peter Huber Kältemaschinenbau Unistat 510w Dynamisches Peter Huber Kältemaschinenbau Unistat 515w Dynamisches Peter Huber Kältemaschinenbau Unistat 520w Dynamisches Peter Huber Kältemaschinenbau Unistat 525 Dynamisches Peter Huber Kältemaschinenbau Unistat 525w Dynamisches Peter Huber Kältemaschinenbau Unistat 527w Dynamisches Peter Huber Kältemaschinenbau Unistat 530w Dynamisches Peter Huber Kältemaschinenbau Unistat 540w Dynamisches Peter Huber Kältemaschinenbau Unistat 545w Dynamisches Peter Huber Kältemaschinenbau Unistat 610w Dynamisches Peter Huber Kältemaschinenbau Unistat 615w Dynamisches Peter Huber Kältemaschinenbau Unistat 620w Dynamisches Peter Huber Kältemaschinenbau Unistat 625w Dynamisches Peter Huber Kältemaschinenbau Unistat 630w Dynamisches Peter Huber Kältemaschinenbau Unistat 635w Dynamisches Peter Huber Kältemaschinenbau Unistat 640w Dynamisches Peter Huber Kältemaschinenbau Unistat 645w Dynamisches Peter Huber Kältemaschinenbau Unistat 650w Dynamisches Peter Huber Kältemaschinenbau Unistat 680w Dynamisches Peter Huber Kältemaschinenbau Unistat 705w Dynamisches Peter Huber Kältemaschinenbau Unistat 815w Dynamisches Peter Huber Kältemaschinenbau Unistat 825w Dynamisches Peter Huber Kältemaschinenbau Unistat 905w Dynamisches Peter Huber Kältemaschinenbau Unistat 912w Dynamisches Peter Huber Kältemaschinenbau Unistat 915w Dynamisches Peter Huber Kältemaschinenbau Unistat 920w Dynamisches Peter Huber Kältemaschinenbau Unistat 930w Dynamisches Peter Huber Kältemaschinenbau Unistat 950w Dynamisches Peter Huber Kältemaschinenbau Unistat GL 530w Dynamisches Peter Huber Kältemaschinenbau Unistat GL 535w Dynamisches Peter Huber Kältemaschinenbau Unistat GL 540w Dynamisches Peter Huber Kältemaschinenbau Unistat GL 550w Dynamisches Peter Huber Kältemaschinenbau Unistat GL 560w Dynamisches Peter Huber Kältemaschinenbau Unistat GL 570w Dynamisches Peter Huber Kältemaschinenbau Unistat GL P530w Dynamisches Peter Huber Kältemaschinenbau Unistat GL P535w Dynamisches Peter Huber Kältemaschinenbau Unistat GL P540w Dynamisches Peter Huber Kältemaschinenbau Unistat GL P550w Dynamisches Peter Huber Kältemaschinenbau Unistat GL P560w Dynamisches Peter Huber Kältemaschinenbau Unistat GL P570w Dynamisches Peter Huber Kältemaschinenbau Unistat P405w Dynamisches Peter Huber Kältemaschinenbau Unistat P425 Dynamisches Peter Huber Kältemaschinenbau Unistat P425w Dynamisches Peter Huber Kältemaschinenbau Unistat P430 Dynamisches Peter Huber Kältemaschinenbau Unistat P430w Dynamisches Peter Huber Kältemaschinenbau Unistat P510 Dynamisches Peter Huber Kältemaschinenbau Unistat P510w Dynamisches Peter Huber Kältemaschinenbau Unistat P515w Dynamisches Peter Huber Kältemaschinenbau Unistat P520 Dynamisches Peter Huber Kältemaschinenbau Unistat P520w Dynamisches Peter Huber Kältemaschinenbau Unistat P525 Dynamisches Peter Huber Kältemaschinenbau Unistat P525w Dynamisches Peter Huber Kältemaschinenbau Unistat P527w Dynamisches Peter Huber Kältemaschinenbau Unistat P530w Dynamisches Peter Huber Kältemaschinenbau Unistat P540w Dynamisches Peter Huber Kältemaschinenbau Unistat P545w Dynamisches Peter Huber Kältemaschinenbau Unistat P610 Dynamisches Peter Huber Kältemaschinenbau Unistat P610w Dynamisches Peter Huber Kältemaschinenbau Unistat P615 Dynamisches Peter Huber Kältemaschinenbau Unistat P615w Dynamisches Peter Huber Kältemaschinenbau Unistat P620w Dynamisches Peter Huber Kältemaschinenbau Unistat P625w Dynamisches Peter Huber Kältemaschinenbau Unistat P630w Dynamisches Peter Huber Kältemaschinenbau Unistat P635w Dynamisches Peter Huber Kältemaschinenbau Unistat P645w Dynamisches Peter Huber Kältemaschinenbau Unistat P650w Dynamisches Peter Huber Kältemaschinenbau Unistat P815 Dynamisches Peter Huber Kältemaschinenbau Unistat P815w Dynamisches Peter Huber Kältemaschinenbau Unistat P825 Dynamisches Peter Huber Kältemaschinenbau Unistat P825w Dynamisches Peter Huber Kältemaschinenbau Unistat P905 Dynamisches Peter Huber Kältemaschinenbau Unistat P905w Dynamisches Peter Huber Kältemaschinenbau Unistat P912w Dynamisches Peter Huber Kältemaschinenbau Unistat P915w Dynamisches Peter Huber Kältemaschinenbau Unistat P920w Dynamisches Peter Huber Kältemaschinenbau Unistat P925w Dynamisches Peter Huber Kältemaschinenbau Unistat P930w Dynamisches Peter Huber Kältemaschinenbau Unistat P950w Dynamisches Peter Huber Kältemaschinenbau Unistat T305 Dynamisches Peter Huber Kältemaschinenbau Unistat T305 HT Dynamisches Peter Huber Kältemaschinenbau Unistat T305w HT Dynamisches Peter Huber Kältemaschinenbau Unistat T320 Dynamisches Peter Huber Kältemaschinenbau Unistat T320w HT Dynamisches Peter Huber Kältemaschinenbau Unistat T330 HT Dynamisches Peter Huber Kältemaschinenbau Unistat T330w HT Dynamisches Peter Huber Kältemaschinenbau Unistat T340 Dynamisches Peter Huber Kältemaschinenbau Unistat T340 HT Dynamisches Peter Huber Kältemaschinenbau Unistat T345 Dynamisches Peter Huber Kältemaschinenbau Unistat T345 HT Dynamisches Peter Huber Kältemaschinenbau Unistat T350 HT Dynamisches Peter Huber Kältemaschinenbau Unistat T402 Dynamisches Peter Huber Kältemaschinenbau Unistat TR401 Dynamisches Peter Huber Kältemaschinenbau Unistat TR402 Dynamisches