Shimadzu Cell Picker
Shimadzu ·Fabriqué en Japan · En production active

Shimadzu Cell Picker

Shimadzu Cell Picker — Life science instruments.

Shimadzu Cell Picker — Life science instruments.

Télécharger la fiche (PDF)

Spécifications complètes

Prestaciones y funciones principales
Configuration picking unit, microscope, microscope camera (CELL PICKER)
Air flow (Desktop Clean Bench, ± 20%) mfr 6.4 m3/min (Desktop Clean Bench, ± 20%)
Pickup volume (example procedural record) mfr 5 μL (example procedural record)
Pickup speed (example procedural record) mfr 16 μL/sec (example procedural record)
Sample volume (UV-1900i) mfr 10 mm standard cell = 2.5 to 4.0 mL; TrayCell = (UV-1900i)
Wavelength range (UV-1900i) mfr 190 to 1,100 nm (UV-1900i)
Spectral bandwidth (UV-1900i) mfr 1 nm (UV-1900i)
Light source (UV-1900i) mfr 20 W halogen lamp and deuterium lamp (UV-1900i)
Monochromator (UV-1900i) mfr LO-RAY-LIGH grade blazed holographic grating in (UV-1900i)
Detector (UV-1900i) mfr Silicon photodiode (UV-1900i)
Sample compartment internal dimensions (UV-1900i) mfr W 110 × D 250 × H 115 mm (UV-1900i)
Distance between light beams (UV-1900i) mfr 100 mm (UV-1900i)
Dimensions (UV-1900i) mfr W 450 × D 501 × H 244 mm (UV-1900i)
Output device (UV-1900i) mfr USB memory (optional); Extended memory (optional (UV-1900i)
Scan speed (UV-1900i) mfr up to 29,000 nm/min (UV-1900i)
Picking time per colony (verification test, 48 colonies) mfr 2 minutes (verification test, 48 colonies)
Picking time for 48 colonies (manual operation) mfr 90 min (manual operation)
Picking time for 48 colonies mfr Less than 2 minutes per colony (CELL PICKER)
Picking time for 48 colonies mfr 60 min
Moving the cultivation container and searching for cells mfr No
Determining a target mfr No
Attaching a tip to the pipetter mfr Yes
Collecting cells mfr Yes
Determining the seeding positions mfr Yes
Seeding mfr Yes
Discarding the tip mfr Yes
Dimensiones, peso y diseño mecánico
Hauteur 456 mm (CELL PICKER)
Largeur 448 mm (CELL PICKER)
Weight mfr 8.5 kg (CELL PICKER)
Weight (CELL PICKER System with AUTO CHANGER) mfr 15.5 kg (CELL PICKER System with AUTO CHANGER)
Weight (AUTO CHANGER) mfr 7 kg (AUTO CHANGER)
Depth mfr 536 mm (CELL PICKER)
Width (CELL PICKER System with AUTO CHANGER) mfr 585 mm (CELL PICKER System with AUTO CHANGER)
Depth (CELL PICKER System with AUTO CHANGER) mfr 536 mm (CELL PICKER System with AUTO CHANGER)
Height (CELL PICKER System with AUTO CHANGER) mfr 456 mm (CELL PICKER System with AUTO CHANGER)
Width (CELL PICKER, not including microscope) mfr 248 mm (CELL PICKER, not including microscope)
Depth (CELL PICKER, not including microscope) mfr 355 mm (CELL PICKER, not including microscope)
Height (CELL PICKER, not including microscope) mfr 372 mm (CELL PICKER, not including microscope)
Width (CELL PICKER System with AUTO CHANGER, not including microscope) mfr 385 mm (CELL PICKER System with AUTO CHANGER, not including microsco)
Depth (CELL PICKER System with AUTO CHANGER, not including microscope) mfr 355 mm (CELL PICKER System with AUTO CHANGER, not including microsco)
Height (CELL PICKER System with AUTO CHANGER, not including microscope) mfr 372 mm (CELL PICKER System with AUTO CHANGER, not including microsco)
Weight (Desktop Clean Bench) mfr Approximately 75 Kg (Desktop Clean Bench)
Weight (UV-1900i) mfr 16.6 kg (UV-1900i)
Interfaces, conexiones y control
Display (UV-1900i) mfr 24-bit color touch screen (UV-1900i)

Plans dimensionnels et documentation technique

Documentation technique

PDF
c297-e127
Datasheet ·3,1 МБ ·12 pp.
Voir le PDF
PDF
c10g-e089
Datasheet ·7,7 МБ ·33 pp.
Voir le PDF
PDF
Utilization of CELL PICKER and MCE-202 MultiNA in the field of genome editing - Technical Report
Datasheet ·3,0 МБ ·4 pp.
Voir le PDF