Induztr
Engineering Digest Document Viewer Related Models

Easy-fit Torch ICP-OES User Guide

Contents

  1. Config p. 2
    Available injector and outer tube-set configurations
  2. Procedure p. 3
    Steps before first use of fully demountable torch
  3. Procedure p. 4
    How to disassemble the fully demountable torch
  4. Procedure p. 5
    How to reassemble the fully demountable torch
  5. Procedure p. 6
    How to disassemble the ceramic outer tube-set
  6. Ordering p. 7
    Spare parts and ordering information
  7. Config p. 10
    Available injector and outer tube-set configurations
  8. Procedure p. 11
    Steps before first use of fully demountable torch
  9. Procedure p. 12
    How to disassemble the fully demountable torch
  10. Procedure p. 13
    How to reassemble the fully demountable torch
  11. Procedure p. 14
    How to disassemble the ceramic outer tube-set
  12. Ordering p. 15
    Spare parts and ordering information
  13. Config p. 18
    Available injector and outer tube-set configurations
  14. Procedure p. 19
    Steps before first use of fully demountable torch
  15. Procedure p. 20
    How to disassemble the fully demountable torch
  16. Procedure p. 21
    How to reassemble the fully demountable torch
  17. Procedure p. 22
    How to disassemble the ceramic outer tube-set
  18. Ordering p. 23
    Spare parts and ordering information
  19. Config p. 26
    Available injector and outer tube-set configurations
  20. Procedure p. 27
    Steps before first use of fully demountable torch
  21. Procedure p. 28
    How to disassemble the fully demountable torch
  22. Procedure p. 29
    How to reassemble the fully demountable torch
  23. Overview p. 30
    Overview of the ceramic outer tube-set
  24. Procedure p. 31
    Maintenance and cleaning instructions
  25. p. 32
    References to instructional videos
  26. Config p. 34
    Available injector and outer tube-set configurations
  27. Procedure p. 35
    Steps before first use of fully demountable torch
  28. Procedure p. 36
    How to disassemble the fully demountable torch
  29. Procedure p. 37
    How to reassemble the fully demountable torch
  30. Overview p. 38
    Overview of the ceramic outer tube-set
  31. Procedure p. 39
    How to reassemble the ceramic outer tube-set
  32. Ordering p. 40
    Spare parts and ordering information
  33. Config p. 43
    Available injector and outer tube-set configurations
  34. Procedure p. 44
    Steps before first use of fully demountable torch
  35. Procedure p. 45
    How to disassemble the fully demountable torch
  36. Procedure p. 46
    How to reassemble the fully demountable torch
  37. Procedure p. 47
    How to disassemble the ceramic outer tube-set
  38. Ordering p. 48
    Spare parts and ordering information
  39. Config p. 51
    Available injector and outer tube-set configurations
  40. Procedure p. 52
    Steps before first use of fully demountable torch
  41. Procedure p. 53
    How to disassemble the fully demountable torch
  42. Procedure p. 54
    How to reassemble the fully demountable torch
  43. Procedure p. 55
    How to disassemble the ceramic outer tube-set
  44. Ordering p. 56
    Spare parts and ordering information
  45. Config p. 59
    Available injector and outer tube-set configurations
  46. Procedure p. 60
    Steps before first use of fully demountable torch
  47. Procedure p. 61
    How to disassemble the fully demountable torch
  48. Procedure p. 62
    How to reassemble the fully demountable torch
  49. Procedure p. 63
    How to disassemble the ceramic outer tube-set
  50. Ordering p. 64
    Spare parts and ordering information
  51. p. 7 table, 8 rows
  52. p. 2 table, 3 rows

Replacement Injectors for fully demountable torch used with 5100/5110 and 5800/5900 ICP-OES

DescriptionPart number
0.8mm id quartz injector, recommended for volatile organic solventsG8020-60805
1.4mm id quartz injector, recommended for semi-volatile organic solvents and acidic solutions with RV torch typeG8020-60806
1.8mm id quartz injector, recommended for acidic solutions with DV torch typeG8020-60807
2.4mm id quartz injector, recommended for high TDS samplesG8020-60808
0.8mm id alumina injector (inert), recommended for volatile organic solventsG8020-47002
1.4mm id alumina injector (inert), recommended for alkali metal rich samples (including Li Battery materials) and semi-volatile organic solventsG8020-47003
1.8mm id alumina injector (inert), recommended for HF digestsG8020-47005
2.4mm id alumina injector (inert), recommended for HF digests and high total dissolved solids (TDS) samples (up to 35% TDS)G8020-47004

Table 1 Tube-set and injector options for different applications

ApplicationSuggested outer tube-set materialSuggested injector internal diameter (id)Key benefits / characteristics
Most aqueous or acidic samplesStandard quartz1.8mm idSuitable for general purpose analysis Most economical option
Volatile and semi-volatile organic samples'Organic' high purity quartz0.8mm id (for volatile) & 1.4mm id (for semi-volatile)'Organic' tube-set and inert alumina injectors offer improved resistance to solarization (web-cracking caused by deep UV exposure)
High-TDS matrices rich in alkali metals (including Li battery materials), hydrofluoric (HF) acid digests or fusionsCeramic outer2.4mm id inert (alumina)Longest service life, superior resistance to devitrification Easy to clean

Engineering Facts

11 facts · every claim linked to a page
Installation

The fully demountable torch ships without the injector installed, so the injector must be installed before the torch is fitted to the instrument.

Prevents a failed first installation and ensures the injector is seated correctly before use.

Source
“The torch is shipped without the injector installed.”
Installation

The injector must be pushed fully in until the bulge contacts the retaining clamp and clicks into position.

Confirms correct injector seating and avoids gas leaks or misalignment.

Source
“Fully insert the injector into the torch body until the bulge contacts the retaining clamp and “clicks” into position.”
Installation

The locking nut must be hand-tightened only; overtightening can damage the injector and torch body.

Prevents costly damage to the injector and torch body during assembly.

Source
“Do not overtighten the locking nut. Overtightening can damage the injector and torch body.”
Installation

When reassembling the fully demountable torch, the groove on the torch body must align with the T mark on the outer tube-set.

Ensures correct orientation of the outer tube-set and proper gas flow.

Source
“position it so that the groove on the torch body aligns with the “T” alignment mark on the tube-set”
Maintenance

The polymer adapter on the quartz intermediate tube is fixed and must not be removed.

Removing it would damage the ceramic tube-set and require replacement.

Source
“The quartz intermediate tube has a polymer adapter that is fixed and should not be removed.”
Selection

A 0.8 mm id quartz injector is recommended for volatile organic solvents.

Selecting the correct injector diameter is critical for organic sample analysis.

Source
“0.8mm id quartz injector, recommended for volatile organic solvents”
Selection

A 2.4 mm id alumina injector is recommended for HF digests and high TDS samples up to 35% TDS.

Ensures compatibility with HF and high-matrix samples without injector damage.

Source
“2.4mm id alumina injector (inert), recommended for HF digests and high total dissolved solids (TDS) samples (up to 35% TDS)”
Selection

The ceramic outer tube-set in DV configuration is intended for high TDS, HF digests, or lithium-ion battery materials.

Guides material selection for demanding matrices to maximize tube life.

Source
“Ceramic outer tube-set, DV configuration, for use with high TDS, HF digests or Lithium-ion battery materials”
Safety

Always maintain a straight parallel movement when inserting or removing the torch and quartz/ceramic components to avoid breakage.

Prevents glass breakage and hand injury during handling.

Source
“Always maintain a straight parallel movement when inserting or removing the torch and quartz/ceramic torch components to avoid breaking them.”
Operation

The torch and torch compartment remain extremely hot after plasma shutdown; wait at least five minutes before removing the torch.

Prevents burns and thermal damage to components during maintenance.

Source
“Attendere per almeno cinque minuti il raffreddamento della torcia e del vano torcia prima di tentare di rimuovere la torcia.”
Maintenance

Corrosive acids or chemical residues may be present on torch components and can cause severe burns; wear protective clothing and rinse with water if contact occurs.

Ensures operator safety during cleaning and handling of used torch parts.

Source
“Indossare sempre indumenti protettivi adeguati quando si maneggiano i componenti della torcia e i prodotti chimici per la pulizia.”