0715 EN MKF CO2 E6 UM 10 2026

Technical Reference Summary

Covered Models & Document Scope

Covers the MKF (E6) series of alternating climate chambers with program control: MKF 240, MKF 400, MKF 720 and MKF 1020, each in 400 V / 50 Hz and 480 V / 60 Hz voltage variants. Art. Nos. listed: MKF 240 400V/50Hz 9020-0514/9120-0514, MKF 240 480V/60Hz 9020-0516, MKF 400 400V/50Hz 9020-0519/9120-0519, MKF 400 480V/60Hz 9020-0521/9120-0521, MKF 720 400V/50Hz 9020-0523/9120-0523, MKF 720 480V/60Hz 9020-0525/9120-0525, MKF 1020 400V/50Hz 9020-0528/9120-0528, MKF 1020 480V/60Hz 9020-0530/9120-0530. Options include RS485 interface, analog outputs for temperature and humidity, flexible Pt 100 object temperature sensor, condensate recycling lever, safety kit (hose burst/reflux protection), APT-COM 4 software and BINDER Pure Aqua Service.

Section-by-Section Technical Breakdown

pp. 21-26
Chamber description and controls

Describes the chamber layout, main power switch, signal triangle, ergonomically adjustable control terminal, lateral control panel and rear chamber view. These elements define the physical interfaces used during installation and operation.

  • Main power switch and signal triangle are described as part of the chamber front/control area
  • Control terminal is ergonomically adjustable
  • Lateral control panel and rear chamber view are documented for connection and service access
pp. 31-36
Installation and connections

Covers wastewater connection, freshwater supply (automatic via water pipe or manual via internal freshwater can), condensate recycling lever option, connection kit for freshwater pipe, hose burst/reflux safety kit and electrical connection. These determine the water and power interfaces required before start-up.

  • Wastewater connection for humidifying system
  • Automatic freshwater supply via water pipe or manual supply via internal freshwater can
  • Optional lever for condensate recycling
  • Connection kit for connecting freshwater connection to a water pipe
  • Safety kit with hose burst protection and reflux protection available via BINDER Customized Solutions
  • Electrical connection requirements
pp. 37-46
MB2 chamber controller functional overview

Introduces the MB2 controller: normal display, program display and chart-recorder display, controller icons, operating modes, menu structure (main menu, Settings, Service), entry principle, and behavior during power failures and when opening the door.

  • Normal display, program display and chart-recorder display views
  • Controller icons overview
  • Operating modes and menu structure including Settings and Service submenus
  • Performance during and after power failures
  • Performance when opening the door
pp. 46-48
Start up

Describes turning on the chamber, controller settings upon start up, and turning humidity control on/off. These steps are required before set-point entry or program operation.

  • Turning on the chamber
  • Controller settings upon start up
  • Turning humidity control on/off
pp. 48-50
Set-point entry in Fixed value operating mode

Explains entering setpoints through the Setpoints menu or directly via the Normal display, plus special controller functions available in fixed-value mode.

  • Set-point entry through the Setpoints menu
  • Direct setpoint entry via Normal display
  • Special controller functions
pp. 51-52
Timer program: stopwatch function

Covers starting a timer program, performance during program delay time, cancelling a running timer program, and performance after the end of the program.

  • Starting a timer program
  • Performance during program delay time
  • Cancelling a running timer program
  • Performance after the end of the program
pp. 52-65
Time programs

Describes starting and cancelling existing time programs, creating new time programs, program management, section management, value entry for sections (duration, set-point ramp/step, special functions, setpoint, tolerance range, repetition) and saving programs.

  • Starting and cancelling existing time programs
  • Creating a new time program
  • Program editor: deleting a time program
  • Section editor: add, copy/insert/replace, delete program sections
  • Value entry: section duration, set-point ramp and step, special controller functions, setpoint, tolerance range
  • Repeating sections within a time program and saving the program
pp. 66-74
Week programs

Covers starting and cancelling week programs, creating new week programs, program and section management, and value entry including set-point ramp/step modes, weekday, start time, setpoint and special controller functions.

  • Starting and cancelling a running week program
  • Creating a new week program
  • Program editor: deleting a week program
  • Section editor: add, copy/insert/replace, delete sections
  • Value entry: set-point ramp and step modes, weekday, start time, setpoint, special controller functions
pp. 75-79
Notification and alarm functions

Provides an overview of notifications and alarm messages, messages concerning the humidity system, the state of alarm, resetting alarms and the list of active alarms, and activating/deactivating the audible alarm buzzer.

  • Notifications and alarm messages overview
  • Messages concerning the humidity system
  • State of alarm and resetting an alarm / list of active alarms
  • Activating/deactivating the audible alarm (alarm buzzer)
pp. 79-82
Temperature safety devices

Describes the over temperature protective device (class 1), the safety controller (over temperature safety device class 2) including modes, setting, alarm-state message/measures and function check, and the optional over/under temperature safety device class 2.

  • Over temperature protective device (class 1)
  • Safety controller (over temperature safety device class 2): modes, setting, message and measures in alarm state, function check
  • Over/under temperature safety device class 2 (option)
pp. 83-92
User management

Covers authorization levels and password protection, login/logout, user change, password assignment and change, deleting passwords for individual authorization levels, new password assignment when password function was deactivated, and activation code.

  • Authorization levels and password protection
  • Log in, log out, user change
  • Password assignment and password change
  • Deleting the password for an individual authorization level
  • New password assignment for service or admin level when password function was deactivated
  • Activation code
pp. 93-101
General controller settings

Covers menu language, date and time, temperature unit, display configuration (display parameters and touchscreen calibration), network and communication (serial interfaces, Ethernet, E-Mail), USB data transfer, and automatic interior lighting turn-off.

  • Selecting menu language, setting date and time, selecting temperature unit
  • Display configuration and touchscreen calibration
  • Network and communication: serial interfaces, Ethernet, E-Mail
  • USB menu: data transfer via USB interface
  • Turning off interior lighting automatically
pp. 101-103
General information

Provides the service contact page, current operating parameters, event list and technical chamber information accessible from the controller.

  • Service contact page
  • Current operating parameters
  • Event list
  • Technical chamber information
pp. 104-108
Chart recorder display

Describes chart recorder views, showing/hiding the legend, switching legend pages, showing/hiding specific indications, history display, and setting the parameters.

  • Views and legend handling
  • Show/hide specific indications
  • History display
  • Setting the parameters
pp. 109-112
Humidification / dehumidification system

Describes the function of the humidifying and dehumidifying system, including the humidifying system, freshwater, wastewater and dehumidifying system.

  • Function of the humidifying and dehumidifying system
  • Humidifying system
  • Freshwater and wastewater
  • Dehumidifying system
pp. 112-113
Defrosting and anti-condensation protection

Covers defrosting during refrigerating operation and anti-condensation protection measures.

  • Defrosting at refrigerating operation
  • Anti-condensation protection
pp. 114
Zero-voltage switching outputs

Describes the zero-voltage switching outputs available for external switching or signaling.

  • Zero-voltage switching outputs
pp. 115-117
Options and accessories

Lists options and accessories: APT-COM 4 Multi Management Software (Basic Edition), RS485 interface, analog outputs for temperature and humidity, object temperature display with flexible Pt 100 sensor, and BINDER Pure Aqua Service.

  • APT-COM 4 Multi Management Software (accessory), Basic Edition
  • RS485 interface (option)
  • Analog outputs for temperature and humidity (option)
  • Object temperature display with flexible Pt 100 temperature sensor (option)
  • BINDER Pure Aqua Service (accessory)
pp. 117-119
Cleaning and decontamination

Covers cleaning and decontamination / chemical disinfection procedures for the chamber.

  • Cleaning
  • Decontamination / chemical disinfection
pp. 120-125
Maintenance and service, troubleshooting, repair, testing

Covers personnel qualification, maintenance intervals and service, simple troubleshooting, and returning the chamber to BINDER. Includes annual maintenance, condenser cleaning every 1-2 years, steam humidifier maintenance at least once a year, and a service message after 8760 operating hours or two years.

  • Maintenance at least once a year; refrigeration work documented in service log book
  • Steam humidifier maintenance at least once a year depending on water quality and steam output
  • Condenser cleaning recommended every 1 to 2 years by qualified technician
  • Door gasket replacement only when cold
  • Fan grid behind left maintenance access flap checked weekly; clean by suction if dirty
  • Service message after 8760 operating hours or two years, repeated every two weeks until reset by BINDER Service
  • Simple troubleshooting by operating personnel without technical intervention
pp. 129-142
Technical description

Provides factory calibration and adjustment, over current protection, definition of usable volume, MKF (E6) technical data, equipment and options, accessories and spare parts, heating-up and cooling-down graphs, heat compensation, and dimensions.

  • Factory calibration and adjustment
  • Over current protection
  • Definition of usable volume
  • MKF (E6) technical data
  • Equipment and options (extract)
  • Accessories and spare parts (extract)
  • Heating-up graphs, cooling-down graphs, heat compensation, dimensions

Key Integration, Operating & Safety Requirements

Specification / Condition Engineering Implication Applies To
Nominal temperature of the MKF 720 example type plate is 180 °C / 356 °F. p.11 ↗ Maximum rated operating temperature for the chamber; do not exceed this in setpoints or programs. MKF 720 (example type plate)
MKF 720 example type plate: 6.50 kW / 12.0 A at 400 V / 50 Hz, 3 N~; another type plate indication lists 11.00 kW nominal power and 19.2 A nominal current. p.11 ↗ Electrical supply and protection must be sized for the higher nominal current shown on the actual unit's type plate. MKF 720
Nominal voltage tolerance is +/- 10% at the indicated power frequency. p.12 ↗ Supply voltage must remain within +/-10% of nominal at the specified frequency for safe operation. Whole MKF (E6) series
Refrigerant is R 744 (CO2) with filling weight 2.20 kg; maximum operating pressure 120 bar. p.11 ↗ Refrigeration circuit components and service procedures must be rated for 120 bar CO2; repairs to the refrigeration circuit may currently only be carried out at BINDER. MKF 720 example; refrigeration circuit
IP protection is 20 according to EN 60529. p.12 ↗ The chamber is not protected against water ingress; do not wet the chamber during operation or maintenance. Whole MKF (E6) series
Temperature safety device according to DIN 12880, class 2.0. p.12 ↗ The chamber includes a class 2.0 temperature safety device; safety controller settings and function checks must follow Section 12. Whole MKF (E6) series
Operation only with residual current circuit breakers type B (label on chamber). p.9 ↗ Electrical installation must provide a type B RCD for the chamber supply. Whole MKF (E6) series
Annual repeat electrical inspection required, plus test prior to initial startup and prior to resuming operation after maintenance or repair; recommended per EN 50678/VDE 0701 and EN 50699/VDE 0702. p.120 ↗ Plan periodic electrical safety testing and post-maintenance testing before returning the chamber to service. Whole MKF (E6) series
Maintenance work at least once a year; all work on the refrigeration system must be documented in a service log book. p.121 ↗ Establish an annual maintenance schedule and keep equipment records for refrigeration work. Whole MKF (E6) series
Steam humidifier maintenance at least once a year; operating behavior and maintenance intervals depend on available water quality and amount of steam produced. p.121 ↗ Water quality directly affects humidifier maintenance frequency; monitor and plan accordingly. Chambers with humidification system
Condensers recommended to be cleaned every 1 to 2 years by a qualified technician. p.121 ↗ Schedule condenser cleaning in the maintenance plan to maintain refrigeration performance. Whole MKF (E6) series
Door gasket must be replaced only when cold. p.121 ↗ Replacing the gasket while warm may damage it; allow the chamber to cool first. Whole MKF (E6) series
With increased dust in ambient air, clean the condenser fan several times a year; check fan grid behind the left maintenance access flap every week and clean by suction if visibly dirty after disconnecting the chamber. p.121 ↗ Dusty environments require more frequent fan/grid inspection and cleaning to avoid overheating. Whole MKF (E6) series
After 8760 operating hours or two years a service message appears; after confirmation it reappears every two weeks until reset by BINDER Service. p.121 ↗ Plan for BINDER Service reset at the two-year/8760-hour service interval; the message will recur until reset. Whole MKF (E6) series
Humidity sensor resistance data: maximum workplace threshold limit values and tolerated concentrations with permanent load are tabulated for substances including ammonia, acetone, benzene, chlorine, acetic acid, ethyl acetate, ethanol, ethylene glycol, formaldehyde, isopropanol, methanol, methyl ethyl ketone, ozone, hydrochloric acid, hydrogen sulphide, nitrogen oxides, sulphur dioxide, toluol and xylene. p.20 ↗ Chamber atmosphere must not exceed the listed tolerated concentrations with permanent load to avoid damaging the humidity sensor. Chambers with humidity sensor
Tolerated error for simultaneous condensation is ± 2 % r.h. p.20 ↗ Humidity control accuracy under simultaneous condensation conditions is ±2 % r.h. Chambers with humidity control
Required room volume must be calculated according to EN 378-1:2016+A1:2020. p.13 ↗ Installation room volume must be verified per EN 378-1 for refrigerant safety. Whole MKF (E6) series
Do not install the chamber in unventilated recesses; observe prescribed minimum distances (chap. 3.4). p.13 ↗ Ensure sufficient ventilation and minimum clearances to disperse heat and avoid overheating. Whole MKF (E6) series
Repairs to the refrigeration circuit may currently only be carried out at BINDER. p.120 ↗ On-site refrigeration repair is not permitted; arrange return/repair through BINDER. Whole MKF (E6) series
Maintenance work at the refrigeration system must only be conducted by qualified personnel trained per EN 13313:2010 (e.g. refrigeration technician with certified expert knowledge acc. to Regulation (EU) 303/2008). p.120 ↗ Verify service personnel qualifications before any refrigeration system work. Whole MKF (E6) series