Two Dimensions for Elevate Complex Separations with 2D-LC
Contents
Overviewpp. 1-4
Introduces 2D-LC benefits and one solution for all needs
Specpp. 5-6
Describes unique valve technology and multiple 2D-LC modes
Overviewpp. 7-8
Covers comprehensive 2D-LC and easy-to-use software
Overviewpp. 9-10
Explains novice usability and achieving more separation power
Qualitypp. 11-12
Highlights robust compliant solution and 2D-LC versatility
pp. 13-14
Shows small molecule pharma and forensic toxicology applications
Servicespp. 15-16
Describes services, support, and commitment to innovation
Engineering Facts
14 facts · every claim linked to a page
Performance
The platform supports ultrahigh performance with pressure ranges up to 1,300 bar and fast gradients, which matters when selecting modules for demanding 2D-LC methods.
Pressure capability determines which LC modules and columns can be used and whether fast gradients are feasible.
Source
“Achieve ultrahigh performance for pressure ranges up to 1,300 bar and fast gradients.”
Selection
A single optimized 2D-LC valve is sufficient for both comprehensive 2D-LC and single heart-cutting, simplifying configuration and reducing hardware needs.
Knowing one valve covers both modes helps avoid unnecessary valve purchases and simplifies system setup.
Source
“One valve is sufficient for comprehensive 2D-LC and single heart-cutting.”
Performance
The ASM valve reduces first-dimension solvent effects on second-dimension separations via adjustable predilution, improving resolution and sensitivity.
Solvent mismatch between dimensions can degrade 2D peaks; ASM is a key selection option when method robustness and sensitivity matter.
Source
“Active Solvent Modulation Valve (ASM) minimizes the effect of first dimension solvent on second dimension separations through adjustable predilution, thereby increasing resolution and sensitivity.”
Selection
For biopharma, high-salt, and extreme-pH applications, the Bio 2D-LC Solution uses a biocompatible solvent and sample flow path to preserve biomolecule integrity and system robustness.
Material compatibility of the flow path is a primary selection criterion for biomolecules and harsh mobile phases.
Source
“Its biocompatible solvent and sample flow path ensures full integrity of your biomolecules and keeps your system robust.”
Operation
Multiple heart-cutting combines orthogonal separation and detection systems to provide additional sample information in dedicated chromatogram regions for confident peak purity determination.
This defines when to choose heart-cutting versus comprehensive mode based on the need for targeted peak purity confidence.
Source
“Multiple heart-cutting allows you to combine orthogonal separation and detection systems, providing additional information about your sample in dedicated areas of your chromatogram–for an extra level of confidence.”
Selection
Comprehensive 2D-LC (LC×LC) delivers maximum separation power and highest peak capacity for a complete overview of the entire sample.
Peak capacity and whole-sample coverage are the main reasons to select comprehensive mode over heart-cutting.
Source
“Comprehensive 2D-LC (LC×LC) achieves maximum separation power with highest peak capacity to give you a complete overview of the entire sample and determine every component.”
Operation
Two software platforms are available depending on detector choice: OpenLab CDS for UV and single quadrupole MS, or MassHunter for Q-TOF and triple quadrupole detection.
Software selection must match the detector type, which affects method setup, data analysis, and compliance workflows.
Source
“Use either OpenLab CDS for UV and single quadrupole MS detection or MassHunter for Q-TOF and triple quadrupole detection.”
Operation
Peak-based and dynamic peak parking with an optional first-dimension detector handles samples with unknown or shifting first-dimension retention times.
An optional 1D detector may be needed for robust cut scheduling when retention times are not stable.
Source
“Handle samples with unknown or shifting first dimension retention times using an optional first dimension detector.”
Operation
Multi-inject allows flexible sampling volumes in software without hardware modifications, saving time when analyzing a high-resolution series at once.
This avoids hardware changes and enables efficient high-resolution sampling workflows.
Source
“Use the software for flexibly setting sampling volumes without making hardware modifications.”
Operation
Shifted gradients set second-dimension gradients relative to the first-dimension gradient to maximize resolution and minimize run time.
Gradient shifting is a software-based optimization that affects both resolution and throughput.
Source
“By shifting second dimension gradients depending on the first dimension gradient, resolution can be maximized and run time minimized.”
Operation
2D-LC can desalt LC effluents, making buffer-based LC separations compatible with MS detection.
Desalting in the second dimension enables MS detection when non-volatile buffers are required by the method.
Source
“2D-LC can also be used for desalting LC effluents, making buffer-based LC separations MS compatible.”
Compliance
The 1290 Infinity II 2D-LC with OpenLab CDS meets regulated requirements such as 21 CFR Part 11 for QA/QC labs.
Regulated labs must confirm 21 CFR Part 11 compliance before selecting the software and system configuration.
Source
“Combined with 2D-LC Software for OpenLab CDS, the solution also delivers the compliance QA/QC labs need, meeting regulated requirements such as 21 CFR Part 11.”
Compliance
The Agilent automated compliance engine (ACE) includes dedicated protocols for qualifying Agilent 1290 Infinity II 2D-LC Systems.
Qualification protocols are needed during installation and ongoing compliance maintenance.
Source
“And, the Agilent automated compliance engine (ACE) includes dedicated protocols for qualifying Agilent 1290 Infinity II 2D-LC Systems.”
Maintenance
A service plan with annual preventive maintenance can reduce instrument downtime by up to 24%.
Preventive maintenance planning directly affects uptime and operating cost after installation.
Source
“Choose a service plan with annual preventive maintenance for up to 24% less instrument downtime, saving you countless hours and thousands of dollars each year.”