Agilent Technologies 2D-LC System
Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies 2D-LC System

Agilent Technologies 2D-LC System — Liquid chromatography with Max pressure 130 megapascal.

The Agilent 2D-LC System is a two-dimensional liquid chromatography cluster built around a 1290 Binary Pump or 1290 Infinity II/III High-Speed Pump as the second-dimension pump, with 6-position/14-port multiple heart-cutting valves storing up to 12 cuts. It supports LC-LC, MHC, HiRes, LCxLC and ASM modes, with 4.6 mm second-dimension columns at typical 1 mL/min flow and 9 ppm carryover.

Max pressure
130 megapascal

Agilent Technologies HPLC Systems Series — Model Comparison & Selection

Model Max pressure, megapascalCarryover, %Column inner diameter, mmMaximum pressure, barSample capacityTypical flow rate, mL/min
2D-LC System Current 1309×10⁻⁴4.6130061441
Analytical HPLC and UHPLC Systems —9×10⁻⁴4.6130061441
GPC/SEC Systems, Macromolecular Analysis and Solution —9×10⁻⁴4.6130061441
Preparative HPLC Systems, InfinityLab LC Purification Solutions —9×10⁻⁴4.6130061441

Full specifications

Core Performance & Functional Specifications
Max pressure 1300 bar
Carryover 9 ppm
Gas Flow 11 L/min
Ion source 6
Maximum pressure 1300 bar
Minimum Dwell Time 200 ms
Sample Capacity 6144 samples
Typical Flow Rate 1 mL/min
Productivity range mfr Micrograms Micrograms
instrument downtime reduction mfr 24
ESI Source Parameter mfr Similar to the High-end MS parameter parameter
SCAN mfr 100...500 mode
Ion Mode mfr Dual AJS ESI ESI
Ion Polarity mfr Positive Positive
Storage Mode mfr Both, Centroid preferred preferred
LCMS Stream mfr MS MS
Acquisition Mode mfr 1
Instrument Parameters mfr Source Parameters Parameters
Nebulizer mfr 40 psig
SheathGasFlow mfr 12 L/min
Scan Segment mfr 1
Fragmentor mfr 120
Skimmer1 mfr 45
OctopoleRFPeak mfr 750
Stop Time mfr As pump/No limit limit
Ion polarity mfr Positive Positive
ReferenceMasses mfr Ref Mass Enabled Enabled
Dimensions, Weight & Mechanical Design
Column Inner Diameter 4.6 mm
Peak Width 0.06 min
Electrical, Power & Drive Specifications
Nozzle Voltage 300 V
Vcap mfr 3500 V
Operating Conditions, Environment & Protection
Gas Temp 250 °C

Description

Architecture and positioning in the series

Behavior in the different modes

Installation, control and operation

Integration & Operating Notes

Process Limits
Second-dimension pump must be a 1290 Binary or High-Speed Pump

No other pump model may serve as the 2D pump in the cluster. If the existing system uses a 1260 pump in the second dimension, it must be replaced before the 2D-LC valve/loop front end can be commissioned, since the manual restricts the 2D pump to the 1290 Binary Pump or any 1290 Infinity II/III High-Speed Pump.

2D-LC System User Manual, Chapter 10, page 312
Process Limits
2D run time must fit between adjacent 1D peaks in heart-cutting

A started second-dimension analysis always runs to completion, so a second peak eluting from the first dimension can be lost if it is sampled while the 2D analysis is still running. Method development must match the second-dimension run time to the retention time between two first-dimension peaks, or move to multiple heart-cutting with loop storage.

2D-LC System User Manual, Chapter 2, page 17
Control & I/O
Never mix firmware sets or cut power during a firmware update

Firmware files from different firmware sets must not be combined, and the power supply of the device and the PC must not be interrupted during a firmware update. Either action can corrupt the module firmware, so schedule updates on a stable supply and use one consistent firmware set across the cluster.

2D-LC System User Manual, Chapter 10, pages 325-326
Maintenance
Checkout differs by pump type: Pump Ripple vs Tuning

For 2D-LC instruments the checkout includes a pressure test of the 1D-LC part, a pressure test of the 2D-LC part, and a pump characteristic test that is Pump Ripple for a 1260 pump and Tuning for a 1290 pump. The correct test must be selected for the pump actually installed in each dimension.

2D-LC System User Manual, Chapter 10, page 338

Selection & Integration Q&A

When should I choose the 2D-LC System rather than the analytical HPLC/UHPLC or bio siblings?

Pick 2D-LC when one-dimensional resolution is insufficient and you need selective heart-cutting, multiple heart-cutting with up to 12 stored cuts, HiRes, LCxLC or ASM. The analytical and application-specific siblings are single-dimension systems; the bio sibling is the biocompatible variant of this same 2D concept.

What must the adjacent pump and software environment provide for this cluster?

The 2D pump must be a 1290 Binary Pump or any 1290 Infinity II/III High-Speed Pump. MassHunter Workstation must license the 2D-LC instrument, the license dongle sits in the 2D pump, and Lab Advisor 2.17+ (2.18+ for the capillary leak test) is needed for configuration and tests.

What duty-cycle or run-preparation limits does the manual impose on heart-cutting operation?

A started second-dimension run always completes, so a following 1D peak can be lost if sampled during it; match 2D run time to the 1D peak spacing or use multiple heart-cutting loops. Before a run, flush both dimensions' flow paths and all sample loops to reduce carryover.

What maintenance parts, tools and accessories are not part of the base delivery?

The USB hardware dongle license, the optional 1D/2D switching valve, ASM capillaries and the analytical fraction collection hardware are options. Service work needs a 1/4-1/5 inch wrench and a blank nut, plus Lab Advisor 2.17/2.18; valve heads and Quick Change Valve Head parts are listed as maintenance parts.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Two Dimensions for Elevate Complex Separations with 2D-LC
Brochure ·3,7 МБ ·16 pp.
View PDF
PDF
Agilent 1260 Infinity II Bio-Inert LC System - Span the Spectrum of Bio LC
Brochure ·2,6 МБ ·16 pp.
View PDF
PDF
Agilent 1290 Infinity II 2D-LC Solution User Guide
Manual ·498 pp.
View PDF