p. 2table, 2 rows
Quantitative Kits
Kit name
Sizing range
Input concentration range
Part number
Kit sizes
gDNA 165 kb Analysis kit
1,300 bp - 165 kb
Fragments: 0.3 - 30 pg/µL
Smears: 5 - 500 pg/µL
FP-1002-0275
275 samples
Ultra Sensitivity NGS kit
100 - 6,000 bp
Fragments: 0.1 - 5 pg/µL
Smears: 25 - 250 pg/µL
FP-1101-0275
275 samples
Engineering Facts
9 facts · every claim linked to a page
Selection
The system can separate genomic DNA up to 165,000 bp, so it must be chosen for very high molecular weight DNA workflows.
Confirms the upper sizing capability needed when selecting the instrument for HMW gDNA applications.
Source
“automate the separation of genomic DNA as large as 165,000 bp”
Selection
The reagent portfolio covers HMW gDNA, long-read NGS libraries, cfDNA, single-cell gDNA, total RNA, FFPE isolates, and BAC clones, so kit choice must match the sample type.
Helps verify application coverage before committing to the platform and consumables.
Source
“The reagent kit portfolio covers a broad range of sample types such as HMW genomic DNA, long-read NGS libraries, cfDNA, single cell genomic DNA, total RNA, FFPE nucleic acid isolates, and bacterial artificial chromosomes (BAC) clones.”
Selection
The gDNA 165 kb Analysis kit supports fragments from 0.3 to 30 pg/µL and smears from 5 to 500 pg/µL, so input concentration must fall within these ranges.
Prevents selecting this kit for samples outside its quantitative input range.
Source
“Fragments: 0.3 - 30 pg/µL
Smears: 5 - 500 pg/µL”
Selection
The Ultra Sensitivity NGS kit covers 100–6,000 bp with fragment inputs of 0.1–5 pg/µL and smear inputs of 25–250 pg/µL.
Defines the low-input NGS sizing and concentration window for correct kit selection.
Source
“Fragments: 0.1 - 5 pg/µL
Smears: 25 - 250 pg/µL”
Selection
The Ultra Sensitivity RNA kit covers 200–6,000 nt with total RNA inputs of 15–250 pg/µL and mRNA inputs of 25–500 pg/µL.
Ensures RNA samples are within the kit's validated concentration range before use.
Source
“Total RNA: 15 - 250 pg/µL
mRNA: 25 - 500 pg/µL”
Selection
The 55 kb BAC kit has a sizing range of 75 bp to 48,500 kb and requires 3–25 pg/µL for fragments up to 48 kb and 1–12.5 pg/µL for fragments below 2 kb.
Guides BAC kit selection and input normalization for the intended fragment size class.
Source
“Fragment up to 48 kb: 3 - 25 pg/µL
Fragment <2 kb: 1 - 12.5 pg/µL”
Selection
The 165 kb BAC kit covers 75 bp to 165 kb and specifies different input ranges for fragments below 48 kb, above 48 kb, and multiple fragments.
Prevents over- or under-loading BAC samples when selecting the high-range BAC kit.