Technical Data Sheet — G-BH1 2BH1310 vacuum pump (EN)
Technical Reference Summary
Covered Models & Document Scope
Data sheet 2BH1 310 side channel blower (G-BH1 series). Covers 2BH1310-1HH26 and 2BH1310-1HC23 single-phase variants (50/60 Hz) and 2BH1310-..□.□ three-phase motor variants with voltage-range/fixed-voltage/VFD options (H1, H6, H7, C3, C5, P3, P5, P6, P7).
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Rated pressure | 200-240 Δ / 345-415 Y V p.2 ↗ | 2BH1310-1HH26, 50 Hz |
| Current | 3,8 Δ / 2,20 Y A p.2 ↗ | 2BH1310-1HH26, 50 Hz |
| Power | 0,70 kW p.2 ↗ | 2BH1310-1HH26, 50 Hz |
| Max. differential pressure vacuum | -210 mbar p.2 ↗ | 2BH1310-1HH26, 50 Hz |
| Max. differential pressure pressure level | 240 mbar p.2 ↗ | 2BH1310-1HH26, 50 Hz |
| Noise level | 56 dB(A) p.2 ↗ | 2BH1310-1HH26, 50 Hz |
| Weight | 16 kg p.2 ↗ | 2BH1310-1HH26, 50 Hz |
| Rated pressure | 220-275 Δ / 380-480 Y V p.2 ↗ | 2BH1310-1HH26, 60 Hz |
| Current | 3,75 Δ / 2,15 Y A p.2 ↗ | 2BH1310-1HH26, 60 Hz |
| Power | 0,83 kW p.2 ↗ | 2BH1310-1HH26, 60 Hz |
| Max. differential pressure vacuum | -250 mbar p.2 ↗ | 2BH1310-1HH26, 60 Hz |
| Max. differential pressure pressure level | 250 mbar p.2 ↗ | 2BH1310-1HH26, 60 Hz |
| Noise level | 61 dB(A) p.2 ↗ | 2BH1310-1HH26, 60 Hz |
| Rated pressure | 500 Y V p.2 ↗ | 2BH1310-1HC23, 50 Hz |
| Current | 1,49 Y A p.2 ↗ | 2BH1310-1HC23, 50 Hz |
| Power | 0,70 kW p.2 ↗ | 2BH1310-1HC23, 50 Hz |
| Max. differential pressure vacuum | -210 mbar p.2 ↗ | 2BH1310-1HC23, 50 Hz |
| Max. differential pressure pressure level | 240 mbar p.2 ↗ | 2BH1310-1HC23, 50 Hz |
| Noise level | 56 dB(A) p.2 ↗ | 2BH1310-1HC23, 50 Hz |
| Weight | 16 kg p.2 ↗ | 2BH1310-1HC23, 50 Hz |
| Rated pressure | 575 Y V p.2 ↗ | 2BH1310-1HC23, 60 Hz |
| Current | 1,46 Y A p.2 ↗ | 2BH1310-1HC23, 60 Hz |
| Power | 0,83 kW p.2 ↗ | 2BH1310-1HC23, 60 Hz |
| Max. differential pressure vacuum | -250 mbar p.2 ↗ | 2BH1310-1HC23, 60 Hz |
| Max. differential pressure pressure level | 250 mbar p.2 ↗ | 2BH1310-1HC23, 60 Hz |
Operating Limits
- Max. suction and ambient temperature for stated total pressure differences: 25 °C p.1 ↗
- Protection category: IP 55 p.1 ↗
- Insulation class: F p.1 ↗
- Performance curve tolerance: ± 10 % p.1 ↗
- Three-phase motor voltage tolerance (fixed voltage): ± 10 % p.2 ↗
- Three-phase motor voltage tolerance (voltage range): ± 5 % p.2 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-6 p.2 ↗ | 2BH1310 | Type/size designation (side channel blower, size 310) |
| 8-9 p.2 ↗ | 1H | Motor variant prefix (single-phase H variants) |
| 10-11 p.2 ↗ | H1 / H6 / H7 / C3 / C5 / P3 / P5 / P6 / P7 | Motor/voltage variant code (see ordering table) |
| field 1 p.2 ↗ | H / C / P | Motor series / voltage option group |
| field 2 p.2 ↗ | 1 / 6 / 7 / 3 / 5 | Voltage range / fixed voltage / VFD option number |
Ordering Data
| Ordering Code | Part No. | Variant / Code | Applies To | Note |
|---|---|---|---|---|
| 2BH1310-1HH26 p.2 ↗ | 2BH1310-1HH26 | 50/60 Hz, 200-240 Δ / 345-415 Y (50 Hz), 220-275 Δ / 380-480 Y (60 Hz) | Single-phase motor variant | |
| 2BH1310-1HC23 p.2 ↗ | 2BH1310-1HC23 | 50/60 Hz, 500 Y (50 Hz), 575 Y (60 Hz) | Single-phase motor variant |