Induztr
Engineering Digest Document Viewer Related Models

Technical Data Sheet — G-BH1 2BH1310 vacuum pump (EN)

Technical Reference Summary

Covered Models & Document Scope

Data sheet 2BH1 310 side channel blower (G-BH1 series). Covers 2BH1310-1HH26 and 2BH1310-1HC23 single-phase variants (50/60 Hz) and 2BH1310-..□.□ three-phase motor variants with voltage-range/fixed-voltage/VFD options (H1, H6, H7, C3, C5, P3, P5, P6, P7).

Technical Data

Parameter Value Condition
Rated pressure 200-240 Δ / 345-415 Y V p.2 ↗ 2BH1310-1HH26, 50 Hz
Current 3,8 Δ / 2,20 Y A p.2 ↗ 2BH1310-1HH26, 50 Hz
Power 0,70 kW p.2 ↗ 2BH1310-1HH26, 50 Hz
Max. differential pressure vacuum -210 mbar p.2 ↗ 2BH1310-1HH26, 50 Hz
Max. differential pressure pressure level 240 mbar p.2 ↗ 2BH1310-1HH26, 50 Hz
Noise level 56 dB(A) p.2 ↗ 2BH1310-1HH26, 50 Hz
Weight 16 kg p.2 ↗ 2BH1310-1HH26, 50 Hz
Rated pressure 220-275 Δ / 380-480 Y V p.2 ↗ 2BH1310-1HH26, 60 Hz
Current 3,75 Δ / 2,15 Y A p.2 ↗ 2BH1310-1HH26, 60 Hz
Power 0,83 kW p.2 ↗ 2BH1310-1HH26, 60 Hz
Max. differential pressure vacuum -250 mbar p.2 ↗ 2BH1310-1HH26, 60 Hz
Max. differential pressure pressure level 250 mbar p.2 ↗ 2BH1310-1HH26, 60 Hz
Noise level 61 dB(A) p.2 ↗ 2BH1310-1HH26, 60 Hz
Rated pressure 500 Y V p.2 ↗ 2BH1310-1HC23, 50 Hz
Current 1,49 Y A p.2 ↗ 2BH1310-1HC23, 50 Hz
Power 0,70 kW p.2 ↗ 2BH1310-1HC23, 50 Hz
Max. differential pressure vacuum -210 mbar p.2 ↗ 2BH1310-1HC23, 50 Hz
Max. differential pressure pressure level 240 mbar p.2 ↗ 2BH1310-1HC23, 50 Hz
Noise level 56 dB(A) p.2 ↗ 2BH1310-1HC23, 50 Hz
Weight 16 kg p.2 ↗ 2BH1310-1HC23, 50 Hz
Rated pressure 575 Y V p.2 ↗ 2BH1310-1HC23, 60 Hz
Current 1,46 Y A p.2 ↗ 2BH1310-1HC23, 60 Hz
Power 0,83 kW p.2 ↗ 2BH1310-1HC23, 60 Hz
Max. differential pressure vacuum -250 mbar p.2 ↗ 2BH1310-1HC23, 60 Hz
Max. differential pressure pressure level 250 mbar p.2 ↗ 2BH1310-1HC23, 60 Hz

Operating Limits

  • Max. suction and ambient temperature for stated total pressure differences: 25 °C p.1 ↗
  • Protection category: IP 55 p.1 ↗
  • Insulation class: F p.1 ↗
  • Performance curve tolerance: ± 10 % p.1 ↗
  • Three-phase motor voltage tolerance (fixed voltage): ± 10 % p.2 ↗
  • Three-phase motor voltage tolerance (voltage range): ± 5 % p.2 ↗

Type Code Decoder

Position Token Meaning
1-6 p.2 ↗ 2BH1310 Type/size designation (side channel blower, size 310)
8-9 p.2 ↗ 1H Motor variant prefix (single-phase H variants)
10-11 p.2 ↗ H1 / H6 / H7 / C3 / C5 / P3 / P5 / P6 / P7 Motor/voltage variant code (see ordering table)
field 1 p.2 ↗ H / C / P Motor series / voltage option group
field 2 p.2 ↗ 1 / 6 / 7 / 3 / 5 Voltage range / fixed voltage / VFD option number

Ordering Data

Ordering Code Part No. Variant / Code Applies To Note
2BH1310-1HH26 p.2 ↗ 2BH1310-1HH26 50/60 Hz, 200-240 Δ / 345-415 Y (50 Hz), 220-275 Δ / 380-480 Y (60 Hz) Single-phase motor variant
2BH1310-1HC23 p.2 ↗ 2BH1310-1HC23 50/60 Hz, 500 Y (50 Hz), 575 Y (60 Hz) Single-phase motor variant

Related models