Elmo Rietschle 2BH1310
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle 2BH1310

Elmo Rietschle 2BH1310 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -210 mbar, Motor power 0.83 kW, Noise level 61 dB.

The 2BH1310 is a side-channel (regenerative) blower in Elmo Rietschle's G-BH1 series, configured as a single-stage unit with a 1.49 kW (50 Hz) / 1.46 kW (60 Hz) motor and IP55 protection. It delivers up to 210 mbar differential pressure at 50 Hz and 250 mbar at 60 Hz in both vacuum and pressure modes, distinguishing it from smaller siblings like the 2BH1009 and 2BH1014 by higher pressure capability. It is used for contactless conveying, vacuum holding, and aeration in industrial systems where oil-free, pulsation-free air is required.

Max. differential pressure
-210 mbar
Motor power
0.83 kW
Noise level
61 dB
Weight
16 kg

Elmo Rietschle G-BH1 Series — Model Comparison & Selection

Model Motor power, kWNoise level, dBWeight, kgMax. differential pressure, mbarCurrent, AProtection rating
2BH1310 Current 0.75616-2503.8 Δ / 2.20 YIP55
2BH1009 ——————
2BH1014 0.325711-553.2–6.5IP55
2BH1015 1.36421-1808–16IP55
2BH1023 1.756969-19010–20IP55
2BH1035 2.26470-14014.3–27IP55
2BH1100 0.25310-1201.39 Δ / 0.80 YIP 55
2BH1200 0.294057-401.38 0.8 YIP55
2BH1300 0.2910051-1001.9IP 55
2BH1330 0.298051—1.74 Δ / 1.0 YIP55
2BH1400 0.956116-1805.6IP55
2BH1410 26528-3006.9IP55
2BH1430 1.164161104.2IP55
2BH1490 0.956116-1404.8 VVIP55
2BH1500 0.956521-904.2IP55
2BH1510 47148-4007.6–15.2IP55
2BH1530 1.66925-904.7IP55
2BH1590 1.36121-1902.75IP55
2BH1600 1.7572311309.9IP55
2BH1610 2.575481606IP55
2BH1630 2.56436-16017.1IP55
2BH1640 4.66565-240–26017.1IP55
2BH1690 2.56434-2009.9IP55
2BH1800 5.87713126011–22IP55
2BH1810 9.974188-46030.8IP55
2BH1830 5.875133-16019.4IP55
2BH1900 8.671183-19030.8IP55
2BH1910 12.676295-22026.4IP55
2BH1930 8.675212-8017.6–35.2IP55
2BH1940 19.973303-15063.1IP55
2BH1943 17.377330-16072.2 UU / 36.1 UIP55

Full specifications

Core Performance & Functional Specifications
Max. differential pressure -210 mbar (50 Hz)
60 Hz: -250 mbar
Motor power 0.70 kW (50 Hz)
60 Hz: 0.83 kW
Noise level 56 dB (50 Hz)
60 Hz: 61 dB
Type mfr 2BH1310-1HC23 (50 Hz)
Type mfr 2BH1310-1HH26 (60 Hz)
Max. differential pressure — Vacuum (50 Hz) mfr 210 mbar (50 Hz)
Max. differential pressure — Vacuum (60 Hz) mfr 250 mbar (60 Hz)
Approvals mfr UL 1450 and CAN/CSA 22.2 No 68-09 (certificate n
Rated pressure (vacuum) mfr -210 mbar (50 Hz)
Rated pressure (vacuum) mfr -250 mbar (60 Hz)
Order No. mfr 2BH1310-1HH26
Max. differential pressure (alt 50 Hz) mfr 240 mbar (50 Hz)
Max. differential pressure (alt 60 Hz) mfr 250 mbar (60 Hz)
Dimensions, Weight & Mechanical Design
Weight 16 kg
Electrical, Power & Drive Specifications
Current 3.8 Δ / 2.20 Y A (50 Hz)
60 Hz: 3.75 Δ / 2.15 Y A
Frequency 50 Hz (50 Hz)
60 Hz: 60 Hz
Power supply 3~ 50/60 Hz
Voltage 200-240 Δ / 345-415 Y V (50 Hz)
60 Hz: 220-275 Δ / 380-480 Y V
Operating Conditions, Environment & Protection
Protection rating IP55
Operating temperature 25 degC
Sound pressure level (50 Hz) mfr 56 dB(A) (50 Hz)
Sound pressure level (60 Hz) mfr 61 dB(A) (60 Hz)
Sound pressure level mfr 56 dB(A) (50 Hz)
Sound pressure level mfr 61 dB(A) (60 Hz)

Description

Construction and series positioning

Behavior under load and in different media

Installation, connection, and operation

Integration & Operating Notes

Electrical
Supply voltage must match nameplate variant exactly

The 2BH1310-1HC23 is wound for 200–240 V Δ / 345–415 V Y at 50 Hz, while the 2BH1310-1HH26 is for 220–275 V Δ / 380–480 V Y at 60 Hz. Applying the wrong voltage or frequency will cause overheating, reduced torque, or immediate failure. Verify the nameplate before connection and ensure the supply frequency matches the motor rating.

Technical Data Sheet — G-BH1 2BH1310, Electrical Data

Selection & Integration Q&A

When should I choose the 2BH1310 over the smaller 2BH1009 or 2BH1014?

Choose the 2BH1310 when your process requires up to 210 mbar (50 Hz) or 250 mbar (60 Hz) differential pressure. The 2BH1009 and 2BH1014 offer lower maximum pressure, so they are suitable for lower-pressure applications. The 2BH1310 also provides higher flow at these pressures, but verify the exact operating point against the performance curve.

What are the requirements for the motor starter and overload protection?

Use a contactor or motor starter rated for the motor current: 3.8 A Δ / 2.20 A Y at 50 Hz or 3.75 A Δ / 2.15 A Y at 60 Hz. Set the overload relay to the nameplate current. For delta connection, ensure the supply voltage matches the delta rating. A thermal overload relay with Class 10 trip curve is recommended. If using a VFD, consult the manufacturer for inverter compatibility.

Can the 2BH1310 be installed outdoors or in a wet environment?

The IP55 rating provides protection against dust and water jets, so it can be installed outdoors if protected from direct rain and splashing. However, the standard motor is not designed for continuous condensation. Provide a drip cover and ensure the drain holes are open. Ambient temperature range is typically -20 to +40 °C; check the manual for derating above 40 °C.

What accessories are required for installation but not included in the base delivery?

The base delivery includes the blower only. You must separately order flexible connectors, inlet/outlet flanges or threaded adapters, a suction filter (if needed), a pressure relief valve, and mounting feet or anti-vibration pads. Electrical cables and motor protection devices are also not included. Refer to the accessory list in the technical data sheet for part numbers.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — G-BH1 2BH1310 vacuum pump (EN)
Datasheet ·294,0 КБ ·2 pp.
View PDF