Technical Reference Summary
Covered Models & Document Scope
Data sheet 2BH7 310 side channel blower (G-BH7 series), usable as vacuum pump or compressor. Covers 2BH7310-0AH16-1, 2BH7310-0AH26-1, 2BH7310-0AC13-1, 2BH7310-0AC23-1, 2BH7310-0AV75-7 and the ordering code 2BH7310-0.□.□ with voltage/motor variants H1, H6, H7, C3, C5, P1, P3, P5, P6, P7.
Technical Data
| Parameter |
Value |
Condition |
| Rated pressure (vacuum) |
-250 mbar
p.2 ↗ |
2BH7310-0AH16-1, 50 Hz |
| Max. differential pressure |
250 mbar
p.2 ↗ |
2BH7310-0AH16-1, 50 Hz |
| Voltage |
200-240 / 345-415 Y V
p.2 ↗ |
2BH7310-0AH16-1, 50 Hz |
| Current |
2,8 / 1,6 Y A
p.2 ↗ |
2BH7310-0AH16-1, 50 Hz |
| Power |
0,55 kW
p.2 ↗ |
2BH7310-0AH16-1, 50 Hz |
| Sound pressure level |
58 dB(A)
p.2 ↗ |
2BH7310-0AH16-1, 50 Hz |
| Weight |
17 kg
p.2 ↗ |
2BH7310-0AH16-1, 50 Hz |
| Rated pressure (vacuum) |
-260 mbar
p.2 ↗ |
2BH7310-0AH16-1, 60 Hz |
| Max. differential pressure |
250 mbar
p.2 ↗ |
2BH7310-0AH16-1, 60 Hz |
| Voltage |
220-275 / 380-480 Y V
p.2 ↗ |
2BH7310-0AH16-1, 60 Hz |
| Current |
3,0 / 1,7 Y A
p.2 ↗ |
2BH7310-0AH16-1, 60 Hz |
| Power |
0,63 kW
p.2 ↗ |
2BH7310-0AH16-1, 60 Hz |
| Sound pressure level |
62 dB(A)
p.2 ↗ |
2BH7310-0AH16-1, 60 Hz |
| Weight |
17 kg
p.2 ↗ |
2BH7310-0AH16-1, 60 Hz |
| Rated pressure (vacuum) |
-280 mbar
p.2 ↗ |
2BH7310-0AH26-1, 50 Hz |
| Max. differential pressure |
350 mbar
p.2 ↗ |
2BH7310-0AH26-1, 50 Hz |
| Power |
0,81 kW
p.2 ↗ |
2BH7310-0AH26-1, 50 Hz |
| Weight |
18 kg
p.2 ↗ |
2BH7310-0AH26-1, 50 Hz |
| Rated pressure (vacuum) |
-340 mbar
p.2 ↗ |
2BH7310-0AH26-1, 60 Hz |
| Max. differential pressure |
360 mbar
p.2 ↗ |
2BH7310-0AH26-1, 60 Hz |
| Power |
0,94 kW
p.2 ↗ |
2BH7310-0AH26-1, 60 Hz |
| Protection category |
IP 55
p.1 ↗ |
standard motors |
| Insulation class |
F
p.1 ↗ |
standard motors |
| Max. ambient/suction temperature for stated pressure differences |
25 °C
p.1 ↗ |
|
| Performance curve reference conditions |
15 °C, 1013 mbar, tolerance ± 10 %
p.1 ↗ |
|
Operating Limits
- Max. ambient/suction temperature for stated total pressure differences: 25 °C
p.1 ↗
- Frequency tolerance: +/- 2 %
p.2 ↗
- Converter input voltage suitability of standard motor insulation: up to 460 V
p.2 ↗
- Protection category: IP 55
p.1 ↗
- Insulation class: F
p.1 ↗
Type Code Decoder
| Position |
Token |
Meaning |
| 1-7
p.2 ↗ |
2BH7310 |
Type/size designation (side channel blower, size 310) |
| field 1
p.2 ↗ |
0 |
Fixed digit in ordering code |
| field 2
p.2 ↗ |
H, C, P |
Motor/voltage variant family (H = 50/60 Hz dual-range, C = fixed voltage, P = fixed voltage / VFD) |
| field 3
p.2 ↗ |
1, 6, 7, 3, 5 |
Voltage/motor variant number within the family (H1, H6, H7, C3, C5, P1, P3, P5, P6, P7) |
| field 4
p.2 ↗ |
1, 7 |
Suffix digit of the complete order number (e.g. -1, -7) |
Ordering Data
| Ordering Code |
Part No. |
Variant / Code |
Applies To |
Note |
| 2BH7310-0AH16-1
p.2 ↗ |
2BH7310-0AH16-1 |
H1 |
50/60 Hz, 200-240/345-415 Y (50 Hz), 220-275/380-480 Y (60 Hz) |
0,55/0,63 kW |
| 2BH7310-0AH26-1
p.2 ↗ |
2BH7310-0AH26-1 |
H6 |
50/60 Hz, 200-240/345-415 Y (50 Hz), 220-275/380-480 Y (60 Hz) |
0,81/0,94 kW |
| 2BH7310-0AC13-1
p.2 ↗ |
2BH7310-0AC13-1 |
C3 |
50/60 Hz, 500 Y (50 Hz), 575 Y (60 Hz) |
0,55/0,63 kW |
| 2BH7310-0AC23-1
p.2 ↗ |
2BH7310-0AC23-1 |
C5 |
50/60 Hz, 500 Y (50 Hz), 575 Y (60 Hz) |
0,81/0,94 kW |
| 2BH7310-0AV75-7
p.2 ↗ |
2BH7310-0AV75-7 |
P5 |
50/60 Hz, 115/230 V (50 Hz), 115 V (60 Hz) |
0,94/1,1 kW |