Elmo Rietschle 2BH7310
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle 2BH7310

Elmo Rietschle 2BH7310 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure 250 mbar, Motor power 0.63 kW, Noise level 58 dB.

The 2BH7310 is a single-stage side-channel (regenerative) blower in Elmo Rietschle's G-BH7 series, configured with a 0.94 kW (50 Hz) / 1.06 kW (60 Hz) motor and a 25 kg cast construction. It delivers up to 360 mbar differential pressure in pressure duty and -340 mbar in vacuum duty, distinguishing it from smaller siblings (2BH7210, 2BH7220) by its higher power and pressure capability. It serves as a compact, oil-free air mover for pressure or vacuum holding in industrial processes.

Max. differential pressure
250 mbar
Motor power
0.63 kW
Noise level
58 dB
Ultimate pressure
-260 mbar

Elmo Rietschle G-BH7 Series — Model Comparison & Selection

Model Motor power, kWNoise level, dBMax. differential pressure, mbarWeight, kgCurrent, AVoltage, V
2BH7310 Current 0.6358250—2.8200-240 / 345-415 Y
2BH721 159-300214.2190–210
2BH7210 0.6363-270163.0 △ / 1.7 Y220-275 △ / 380-480 Y
2BH722 1.158480284.8 UU / 2.4 U190-210 UU / 380-420 U
2BH7220 0.8158-440244220-275 / 380-480 Y
2BH731 1.163-340242.8–5.5190-210 / 380-420
2BH732 1.364440333.2190-210 / 380-420
2BH7320 3.577-510486.5—
2BH741 1.363—266.3190–210
2BH7410 2.673-230335.2400
2BH742 1.864460383.9–7.8190-210 / 380-420
2BH7420 2.977-270456.5380
2BH751 1.868-340337.8 UU190-210 UU / 380-420 U
2BH7510 6.6784304312.7400
2BH752 2.564-5205012190-210 / 380-420
2BH7520 4.377-520578.7400 V (-15%) … 480 V (+1
2BH753 5.3699507217.1190–210
2BH7530 7.570-6108016.2400
2BH7610 5.880-4105512.7380
2BH7620 8.879-5307716.2400
2BH7630 1680-50012129400

Full specifications

Core Performance & Functional Specifications
Max. differential pressure 250 mbar (50 Hz)
60 Hz: 250 mbar
Motor power 0.55 kW (50 Hz)
60 Hz: 0.63 kW
Noise level 58 dB (50 Hz)
60 Hz: 62 dB
Ultimate pressure -250 mbar (50 Hz)
60 Hz: -260 mbar
Max. differential pressure vacuum mfr -340 mbar
Order No. mfr 2BH7310-0AV75-7
Rated pressure vacuum mfr -250 mbar (50 Hz)
Max. differential pressure vacuum mfr 350 mbar (50 Hz)
Order No. mfr 2BH7310-0AV75-7 (50 Hz)
Rated pressure vacuum mfr -280 mbar (60 Hz)
Max. differential pressure vacuum mfr 390 mbar (60 Hz)
Atmospheric pressure basis mfr 1013 mbar
Performance curve tolerance mfr ±10 %
Dimensions, Weight & Mechanical Design
Weight mfr 25 kg
Weight approx. mfr 25 kg (50 Hz)
Weight approx. mfr 25 kg (60 Hz)
Electrical, Power & Drive Specifications
Current 2.8 / 1.6 Y A (50 Hz)
60 Hz: 3.0 / 1.7 Y A
Frequency 50 Hz (50 Hz)
60 Hz: 60 Hz
Voltage 200-240 / 345-415 Y V (50 Hz)
60 Hz: 220-275 / 380-480 Y V
Rated voltage mfr 220-275 Δ / 380-480 Y V (60 Hz)
Rated current mfr 4.0 Δ / 2.3 Y A (60 Hz)
Rated voltage mfr 115 / 230 V (50/60 Hz)
Rated current mfr 18.0 / 9.0 A (50/60 Hz)
Frequency tolerance mfr ±2 %
Operating Conditions, Environment & Protection
Protection rating IP55
Operating temperature F
Sound pressure level mfr 58 dB(A) (50 Hz)
Sound pressure level mfr 62 dB(A) (60 Hz)
Sound pressure level mfr 62 dB(A)

Description

Construction and series positioning

Behavior under load and media

Electrical and control specifics

Installation and operation

Integration & Operating Notes

Electrical
Motor connection must match supply voltage and frequency

The 2BH7310 is available with different winding configurations; connecting a 230 V Δ motor to 400 V Y or vice versa will cause immediate damage. Verify the nameplate against the supply and use the correct Δ/Y link bars as shown in the terminal box diagram.

Technical Data Sheet — G-BH7 2BH7310, Electrical Data
Process Limits
Do not exceed 360 mbar pressure or -340 mbar vacuum

Operating above the maximum differential pressure will cause overheating, increased noise, and potential mechanical failure. Install a pressure relief valve or vacuum breaker set to these limits, especially when the blower can dead-head against a closed valve.

Technical Data Sheet — G-BH7 2BH7310, Performance Limits
Mounting
Provide unobstructed cooling air flow around the motor

The motor is fan-cooled; mounting in a confined space or with the fan intake blocked will lead to overheating and reduced service life. Maintain at least the minimum clearance specified in the manual and avoid recirculating hot exhaust air.

Technical Data Sheet — G-BH7 2BH7310, Installation Notes
Control & I/O
Use a motor protection switch or VFD with overload protection

The blower has no built-in thermal protection; an external overload relay or VFD with motor thermal model must be set to the rated current (e.g., 4.0 A Δ at 60 Hz) to prevent winding damage during stall or high-temperature operation.

Technical Data Sheet — G-BH7 2BH7310, Electrical Connection
Maintenance
Inspect and clean the impeller and inlet filter periodically

Dust buildup on the impeller causes imbalance and reduces performance. The service interval depends on the process air cleanliness; in dusty environments, check monthly and clean with compressed air or a soft brush. Replace the inlet filter element when pressure drop becomes noticeable.

Technical Data Sheet — G-BH7 2BH7310, Maintenance

Selection & Integration Q&A

When should I choose the 2BH7310 over the 2BH7210 or 2BH7220?

Choose the 2BH7310 when your process requires up to 360 mbar pressure or -340 mbar vacuum and a motor power around 0.94 kW at 50 Hz. The 2BH7210 and 2BH7220 are smaller siblings with lower power and pressure limits; select them only if the duty point falls within their lower curves, saving cost and space.

What are the requirements for the power supply and starting equipment for the 2BH7310?

The motor is available in 200–240 V (50 Hz) or 220–275 V Δ / 380–480 V Y (60 Hz) versions, drawing up to 4.0 A in Δ at 60 Hz. Use a motor protection switch or VFD rated for the supply voltage and set to the nameplate current. For VFD operation at 87 Hz, ensure the motor is inverter-rated and the drive is configured for the correct V/Hz ratio.

Can the 2BH7310 be installed outdoors or in a high-temperature environment?

The data sheet does not specify an ambient temperature range, but the motor is fan-cooled and relies on free air circulation. For outdoor installation, provide a weatherproof enclosure that does not restrict cooling air. In high-temperature environments, derate the motor or provide additional ventilation to keep winding temperature within Class F limits.

What maintenance items and accessories are not included with the base blower?

The base delivery includes the blower only; inlet/outlet silencers, filters, flexible connectors, pressure relief valves, and motor protection devices must be ordered separately. Maintenance parts such as filter elements and gaskets are also not included. Refer to the spare parts list for the specific variant.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — G-BH7 2BH7310 vacuum pump (EN)
Datasheet ·340,8 КБ ·2 pp.