Technical Data Sheet — G-BH7 2BH7530 side channel blower (EN)

Technical Reference Summary

Covered Models & Document Scope

Data sheet 2BH7 530: side channel blower with integrated frequency converter (VFD), type 2BH7 530. Covers 50 Hz and 60 Hz operation, 87 Hz VFD operation (400 V delta), and integrated VFD types A–K (2FC4xxx) with wall-mount adaptor.

Technical Data

Parameter Value Condition
Rated mains voltage 400 V p.2 ↗ 2BH7530, 50 Hz, delta (U)
Rated motor current 16,2 A p.2 ↗ 2BH7530, 50 Hz, delta (U)
Rated motor power 8,8 kW p.2 ↗ 2BH7530, 50 Hz
Max. differential pressure, vacuum -590 mbar p.2 ↗ 2BH7530, 50 Hz
Max. differential pressure, pressure 600 mbar p.2 ↗ 2BH7530, 50 Hz
Sound pressure level 79 dB(A) p.2 ↗ 2BH7530, 50 Hz
Weight 80 kg p.2 ↗ 2BH7530, 50 Hz
Rated mains voltage 400 V p.2 ↗ 2BH7530, 87 Hz, delta (D)
Rated motor current 14,4 A p.2 ↗ 2BH7530, 87 Hz, delta (D)
Rated motor power 7,5 kW p.2 ↗ 2BH7530, 87 Hz
Max. differential pressure, vacuum -610 mbar p.2 ↗ 2BH7530, 87 Hz
Max. differential pressure, pressure 760 mbar p.2 ↗ 2BH7530, 87 Hz
Sound pressure level 79 dB(A) p.2 ↗ 2BH7530, 87 Hz
Max. differential pressure, vacuum -690 mbar p.2 ↗ 2BH7530, 60 Hz
Max. differential pressure, pressure 900 mbar p.2 ↗ 2BH7530, 60 Hz
Sound pressure level 70 dB(A) p.2 ↗ 2BH7530, 60 Hz
Integrated VFD rated mains voltage 400V (-15%) … 480V (+10%) V p.2 ↗ Integrated VFD, 50/60 Hz ±6%
Protection class IP55 p.2 ↗ Motor and integrated VFD
Insulation material class F p.2 ↗ Motor
VFD pulse frequency 4 kHz p.1 ↗ minimum
Rated voltage/frequency set point 345 V / 87 Hz p.1 ↗ delta connection of motor
Minimum mains voltage for frequency converters 380 V p.1 ↗

Operating Limits

  • Max. ambient/suction temperature for stated pressure differences: 25 °C p.1 ↗
  • Performance curve tolerance: ±10 % p.1 ↗
  • Sound pressure level tolerance: ±3 dB(A) p.2 ↗
  • Protection class: IP55 p.2 ↗
  • Insulation material class: F p.2 ↗

Type Code Decoder

Position Token Meaning
1-6 p.2 ↗ 2BH753 Type/size designation (2BH7 530)
8-12 p.2 ↗ 0A371 / 0A376 / 0AK76 Motor/voltage variant code (U = 400 V delta, D = 400 V delta for 87 Hz, F = VFD variant)
field 1 p.2 ↗ 1 Frequency 50 Hz
field 1 p.2 ↗ 60 Frequency 60 Hz
field 1 p.2 ↗ 87 Frequency 87 Hz (VFD operation)
field 2 p.2 ↗ U 400 V delta connection
field 2 p.2 ↗ D 400 V delta connection for 87 Hz VFD operation
field 3 p.2 ↗ F VFD type F (integrated frequency converter)

Ordering Data

Ordering Code Part No. Variant / Code Applies To Note
2BH7530-0A371-1 p.2 ↗ 2BH7530-0A371-1 50 Hz, 400 V delta (U), VFD type F Complete order number printed
2BH7530-0A376-1 p.2 ↗ 2BH7530-0A376-1 50 Hz, 400 V delta (U), VFD type F Complete order number printed
2BH7530-0AK76-1 p.2 ↗ 2BH7530-0AK76-1 60 Hz, VFD type F Complete order number printed